Modelling of ceramide interactions with porous graphite carbon in non-aqueous liquid chromatography

被引:7
|
作者
West, C
Cilpa, G
Gaudin, K
Chaminade, P
Lesellier, E
机构
[1] Univ Paris 11, LETIAM, IUT Orsay, F-91400 Orsay, France
[2] Fac Pharm Chatenay Malabry, Chim Analyt Lab, F-92296 Chatenay Malabry, France
关键词
non-aqueous reversed-phase liquid chromatography (NARP-LC); linear solvation energy relationship (LSER); ceramides; porous graphitic carbon (PGC);
D O I
10.1016/j.chroma.2005.03.026
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Interactions of solutes on porous graphitic carbon (PGC) with non-aqueous mobile phases are studied by the linear solvation energy relationship (LSER). Studies have been carried out with eight binary mixtures composed of a weak solvent (acetonitrile or methanol) and a strong solvent (tetrahydrofuran, n-butanol, CH2Cl2, 1,1,2-trichloro-2,2,1-trifluoroethane). The systematic analysis of a set of test compounds was performed for each solvent mixture in isocratic mode (50:50). The results were compared to those obtained on PGC with hydro-organic liquids and supercritical fluids. They were then correlated with the observed retention behaviour of lipid compounds, more particularly ceramides. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:77 / 85
页数:9
相关论文
共 50 条
  • [31] Modelling of steam injection for removal of non-aqueous phase
    Cernik, M
    Kvapil, P
    OIL AND HYDROCARBON SPILLS III: MODELLING, ANALYSIS AND CONTROL, 2002, 11 : 277 - 286
  • [32] DETERMINATION OF CARBON DIOXIDE BY NON-AQUEOUS TITRIMETRY
    GRANT, JA
    MASSIE, WHS
    HUNTER, JA
    ANALYST, 1963, 88 (104) : 134 - &
  • [33] Dense non-aqueous phase liquid source zone architecture and dissolution in saturated porous media
    Wang, Hui-Ting
    Xu, Hong-Xia
    Guo, Qiong-Ze
    Shi, Xiao-Qing
    Sun, Yuan-Yuan
    Wu, Ji-Chun
    Zhongguo Huanjing Kexue/China Environmental Science, 2019, 39 (08): : 3474 - 3483
  • [34] Development and optimization of a method for analyzing biodiesel mixtures with non-aqueous reversed phase liquid chromatography
    Di Nicola, G.
    Pacetti, M.
    Polonara, F.
    Santori, G.
    Stryjek, R.
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1190 (1-2) : 120 - 126
  • [35] The determination of carbon by non-aqueous coulometric method
    Ji, L
    Liu, G
    Wang, Y
    Cui, H
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (02) : 247 - 247
  • [36] Influence of Ionic Liquid Species in Non-Aqueous Electrolyte on Sodium Insertion into Hard Carbon
    Egashira, Minato
    Tanaka, Tomoyo
    Yoshimoto, Nobuko
    Morita, Masayuki
    ELECTROCHEMISTRY, 2012, 80 (10) : 755 - 758
  • [37] Liquid chromatography of guanidino compounds using a porous graphite carbon column and application to their analysis in serum
    Inamoto, Y
    Inamoto, S
    Hanai, T
    Tokuda, M
    Hatase, O
    Yoshii, K
    Sugiyama, N
    Kinoshita, T
    JOURNAL OF CHROMATOGRAPHY B, 1998, 707 (1-2): : 111 - 120
  • [39] DETERMINATION OF TRACE WATER IN NON-AQUEOUS SOLVENT BY USE OF LIQUID AMALGAM - LIQUID AMALGAM METHOD IN NON-AQUEOUS MEDIA .2.
    YOSHIMURA, C
    TAMURA, K
    MIYAGUCH.Y
    JAPAN ANALYST, 1972, 21 (08): : 1095 - +
  • [40] Validity of a notion of eluent force taking into account the nature of the graft on silica in aqueous and non-aqueous liquid chromatography.
    Heron, S
    Tchapla, A
    ANALUSIS, 1997, 25 (08) : 257 - 262