Iterative denoising accelerated 3D SPACE FLAIR sequence for brain MR imaging at 3T

被引:11
作者
Eliezer, Michael [1 ,2 ]
Vaussy, Alexis [3 ]
Toupin, Solenn [3 ]
Barbe, Remy [1 ]
Kannengiesser, Stephan [4 ]
Stemmer, Alto [4 ]
Houdart, Emmanuel [1 ,2 ]
机构
[1] Lariboisiere Univ Hosp, Dept Neuroradiol, F-75010 Paris, France
[2] Univ Paris, Fac Med, F-75010 Paris, France
[3] Siemens Healthineers France, F-93210 St Denis, France
[4] Siemens Healthineers, D-91052 Erlangen, Germany
关键词
Magnetic resonance imaging (MRI); 3D FLAIR; Iterative denoising; Brain MRI; MULTIPLE-SCLEROSIS; 2D FLAIR; SUPPRESSION;
D O I
10.1016/j.diii.2021.09.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to prospectively evaluate image quality of three-dimensional fluid attenuated inversion recovery (3D-FLAIR) sequence acquired with a high acceleration factor and reconstructed with iterative denoising (ID) for brain magnetic resonance imaging (MRI) at 3-T. Material and methods: Patients with brain tumor who underwent brain MRI were consecutively included. Two 3D-FLAIR sequences were successively performed for each patient. A first conventional FLAIR acquisition (conv-FLAIR) was performed with an acceleration factor of 6. The second acquisition was performed with an increased acceleration factor of 9. Two series one without ID (acc-FLAIR) and one with ID (acc-FLAIR-ID) were reconstructed. Two neuroradiologists independently assessed image quality, deep brain nuclei visualization and white matter/gray matter (WM/GM) differentiation on a 4-point scale. Results: Thirty patients with brain tumor were consecutively included in this study. There were 16 women and 14 men with a mean age of 54 +/- 17 (SD) years (range: 22-78 years). Scanning time of Acc-FLAIR-ID and Acc-FLAIR (4 min 40 sec) was 37% shorter than that of conv-FLAIR (2 min 50 sec) (P < 0.01). Improved image quality score was significantly different for both conv-FLAIR and acc-FLAIR-ID compared to acc-FLAIR (P < 0.01 for both). WM/GM differentiation score of conv-FLAIR was not significantly different compared to accFLAIR-ID (P = 0.10). Improved WM/GM differentiation score was different for both sequences compared to acc-FLAIR (P = 0.017 and P < 0.001). Deep brain nuclei visualization score was not different between convFLAIR and acc-FLAIR-ID (P = 0.71). However, the improved deep brain nuclei visualization score was signifi-cantly different for both sequences compared to acc-FLAIR (P < 0.001 for both). Conclusion: Scanning time of 3D-FLAIR sequence using a high acceleration factor reconstructed with ID algorithm can be reduced by 37% while preserving image quality for brain MRI. (c) 2021 Societe francaise de radiologie. Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:13 / 20
页数:8
相关论文
共 50 条
[11]   Comparison of 3D double inversion recovery and 2D STIR FLAIR MR sequences for the imaging of optic neuritis: pilot study [J].
Hodel, Jerome ;
Outteryck, Olivier ;
Bocher, Anne-Laure ;
Zephir, Helene ;
Lambert, Oriane ;
Benadjaoud, Mohamed Amine ;
Chechin, David ;
Pruvo, Jean-Pierre ;
Vermersch, Patrick ;
Leclerc, Xavier .
EUROPEAN RADIOLOGY, 2014, 24 (12) :3069-3075
[12]   High-resolution 3D diffusion tensor MRI of anesthetized rhesus macaque brain at 3T [J].
Tounekti, Slimane ;
Troalen, Thomas ;
Bihan-Poudec, Yann ;
Froesel, Mathilda ;
Lamberton, Franck ;
Ozenne, Valery ;
Clery, Justine ;
Richard, Nathalie ;
Descoteaux, Maxime ;
Ben Hamed, Suliann ;
Hiba, Bassem .
NEUROIMAGE, 2018, 181 :149-161
[13]   Correlation of 3D FLAIR and Dopamine Transporter Imaging in Patients With Parkinsonism [J].
Oh, Se Won ;
Shin, Na-Young ;
Lee, Jae Jung ;
Lee, Seung-Koo ;
Lee, Phil Hyu ;
Lim, Soo Mee ;
Kim, Jin Woo .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 207 (05) :1089-1094
[14]   Brain 1H-MR spectroscopy in clinical neuroimaging at 3T [J].
Tchofo, P. Jissendi ;
Baleriaux, D. .
JOURNAL OF NEURORADIOLOGY, 2009, 36 (01) :24-40
[15]   MR Imaging in Multiple Sclerosis: The Accuracy of 3D Double Inversion Recovery at 3 Tesla and the Potential for Single Sequence Imaging [J].
Khangure, S. R. ;
Khangure, M. S. .
NEURORADIOLOGY JOURNAL, 2011, 24 (01) :92-99
[16]   Intravenous enhanced 3D FLAIR imaging to identify CSF leaks in spontaneous intracranial hypotension: Comparison with MR myelography [J].
Osawa, Iichiro ;
Kozawa, Eito ;
Mitsufuji, Takashi ;
Yamamoto, Toshimasa ;
Araki, Nobuo ;
Inoue, Kaiji ;
Niitsu, Mamoru .
EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2021, 8
[17]   Determination of Efficiency of 3D Fluid-Attenuated Inversion Recovery (FLAIR) in the Imaging of Multiple Sclerosis in Comparison With 2D FLAIR at 3-Tesla MRI [J].
Kummari, Satyanarayana ;
Burra, Kiran Goud ;
Reddy, Vudem Ranjith Kumar ;
Das, Saraswata ;
Anilkumar, Challa .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (11)
[18]   The Rim Pattern of Meningioma on 3D FLAIR Imaging: Correlation with Tumor-brain Adhesion and Histological Grading [J].
Enkizono, Mikako ;
Morikawa, Minoru ;
Matsuo, Takayuki ;
Hayashi, Tomayoshi ;
Horie, Nobutaka ;
Honda, Sumihisa ;
Ideguchi, Reiko ;
Nagata, Izumi ;
Uetani, Masataka .
MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2014, 13 (04) :251-260
[19]   Multiple Sclerosis Lesions in the Brain: Computer-Assisted Assessment of Lesion Load Dynamics on 3D FLAIR MR Images [J].
Bilello, M. ;
Arkuszewski, M. ;
Nasrallah, I. ;
Wu, X. ;
Erus, G. ;
Krejza, J. .
NEURORADIOLOGY JOURNAL, 2012, 25 (03) :379-384
[20]   Assessment of Cochlea Endolymphatic Hydrops Using 3-D FLAIR and 3-D Real IR Sequence in Guinea Pigs via 3T MRI After Intratympanic Gadolinium: A Histopathological Comparison [J].
Wang, Feng ;
Lyu, Huiying ;
Zhao, Menglong ;
Sha, Yan ;
Zhang, Fang ;
Cheng, Yushu ;
Huang, Wenhu ;
Tang, Wenlin ;
Xie, Youzhou ;
Lu, Ping .
OTOLOGY & NEUROTOLOGY, 2017, 38 (04) :585-590