Iterative denoising accelerated 3D SPACE FLAIR sequence for brain MR imaging at 3T

被引:11
作者
Eliezer, Michael [1 ,2 ]
Vaussy, Alexis [3 ]
Toupin, Solenn [3 ]
Barbe, Remy [1 ]
Kannengiesser, Stephan [4 ]
Stemmer, Alto [4 ]
Houdart, Emmanuel [1 ,2 ]
机构
[1] Lariboisiere Univ Hosp, Dept Neuroradiol, F-75010 Paris, France
[2] Univ Paris, Fac Med, F-75010 Paris, France
[3] Siemens Healthineers France, F-93210 St Denis, France
[4] Siemens Healthineers, D-91052 Erlangen, Germany
关键词
Magnetic resonance imaging (MRI); 3D FLAIR; Iterative denoising; Brain MRI; MULTIPLE-SCLEROSIS; 2D FLAIR; SUPPRESSION;
D O I
10.1016/j.diii.2021.09.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to prospectively evaluate image quality of three-dimensional fluid attenuated inversion recovery (3D-FLAIR) sequence acquired with a high acceleration factor and reconstructed with iterative denoising (ID) for brain magnetic resonance imaging (MRI) at 3-T. Material and methods: Patients with brain tumor who underwent brain MRI were consecutively included. Two 3D-FLAIR sequences were successively performed for each patient. A first conventional FLAIR acquisition (conv-FLAIR) was performed with an acceleration factor of 6. The second acquisition was performed with an increased acceleration factor of 9. Two series one without ID (acc-FLAIR) and one with ID (acc-FLAIR-ID) were reconstructed. Two neuroradiologists independently assessed image quality, deep brain nuclei visualization and white matter/gray matter (WM/GM) differentiation on a 4-point scale. Results: Thirty patients with brain tumor were consecutively included in this study. There were 16 women and 14 men with a mean age of 54 +/- 17 (SD) years (range: 22-78 years). Scanning time of Acc-FLAIR-ID and Acc-FLAIR (4 min 40 sec) was 37% shorter than that of conv-FLAIR (2 min 50 sec) (P < 0.01). Improved image quality score was significantly different for both conv-FLAIR and acc-FLAIR-ID compared to acc-FLAIR (P < 0.01 for both). WM/GM differentiation score of conv-FLAIR was not significantly different compared to accFLAIR-ID (P = 0.10). Improved WM/GM differentiation score was different for both sequences compared to acc-FLAIR (P = 0.017 and P < 0.001). Deep brain nuclei visualization score was not different between convFLAIR and acc-FLAIR-ID (P = 0.71). However, the improved deep brain nuclei visualization score was signifi-cantly different for both sequences compared to acc-FLAIR (P < 0.001 for both). Conclusion: Scanning time of 3D-FLAIR sequence using a high acceleration factor reconstructed with ID algorithm can be reduced by 37% while preserving image quality for brain MRI. (c) 2021 Societe francaise de radiologie. Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:13 / 20
页数:8
相关论文
共 50 条
  • [11] Comparison of 3D double inversion recovery and 2D STIR FLAIR MR sequences for the imaging of optic neuritis: pilot study
    Hodel, Jerome
    Outteryck, Olivier
    Bocher, Anne-Laure
    Zephir, Helene
    Lambert, Oriane
    Benadjaoud, Mohamed Amine
    Chechin, David
    Pruvo, Jean-Pierre
    Vermersch, Patrick
    Leclerc, Xavier
    EUROPEAN RADIOLOGY, 2014, 24 (12) : 3069 - 3075
  • [12] High-resolution 3D diffusion tensor MRI of anesthetized rhesus macaque brain at 3T
    Tounekti, Slimane
    Troalen, Thomas
    Bihan-Poudec, Yann
    Froesel, Mathilda
    Lamberton, Franck
    Ozenne, Valery
    Clery, Justine
    Richard, Nathalie
    Descoteaux, Maxime
    Ben Hamed, Suliann
    Hiba, Bassem
    NEUROIMAGE, 2018, 181 : 149 - 161
  • [13] Correlation of 3D FLAIR and Dopamine Transporter Imaging in Patients With Parkinsonism
    Oh, Se Won
    Shin, Na-Young
    Lee, Jae Jung
    Lee, Seung-Koo
    Lee, Phil Hyu
    Lim, Soo Mee
    Kim, Jin Woo
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 207 (05) : 1089 - 1094
  • [14] MR Imaging in Multiple Sclerosis: The Accuracy of 3D Double Inversion Recovery at 3 Tesla and the Potential for Single Sequence Imaging
    Khangure, S. R.
    Khangure, M. S.
    NEURORADIOLOGY JOURNAL, 2011, 24 (01) : 92 - 99
  • [15] Brain 1H-MR spectroscopy in clinical neuroimaging at 3T
    Tchofo, P. Jissendi
    Baleriaux, D.
    JOURNAL OF NEURORADIOLOGY, 2009, 36 (01) : 24 - 40
  • [16] Intravenous enhanced 3D FLAIR imaging to identify CSF leaks in spontaneous intracranial hypotension: Comparison with MR myelography
    Osawa, Iichiro
    Kozawa, Eito
    Mitsufuji, Takashi
    Yamamoto, Toshimasa
    Araki, Nobuo
    Inoue, Kaiji
    Niitsu, Mamoru
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2021, 8
  • [17] Determination of Efficiency of 3D Fluid-Attenuated Inversion Recovery (FLAIR) in the Imaging of Multiple Sclerosis in Comparison With 2D FLAIR at 3-Tesla MRI
    Kummari, Satyanarayana
    Burra, Kiran Goud
    Reddy, Vudem Ranjith Kumar
    Das, Saraswata
    Anilkumar, Challa
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (11)
  • [18] The Rim Pattern of Meningioma on 3D FLAIR Imaging: Correlation with Tumor-brain Adhesion and Histological Grading
    Enkizono, Mikako
    Morikawa, Minoru
    Matsuo, Takayuki
    Hayashi, Tomayoshi
    Horie, Nobutaka
    Honda, Sumihisa
    Ideguchi, Reiko
    Nagata, Izumi
    Uetani, Masataka
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2014, 13 (04) : 251 - 260
  • [19] Multiple Sclerosis Lesions in the Brain: Computer-Assisted Assessment of Lesion Load Dynamics on 3D FLAIR MR Images
    Bilello, M.
    Arkuszewski, M.
    Nasrallah, I.
    Wu, X.
    Erus, G.
    Krejza, J.
    NEURORADIOLOGY JOURNAL, 2012, 25 (03) : 379 - 384
  • [20] Multiple Sclerosis Lesions in the Brain: Computer-Assisted Assessment of Lesion Load Dynamics on 3D FLAIR MR Images
    Bilello, M.
    Arkuszewski, M.
    Nasrallah, I.
    Wu, X.
    Erus, G.
    Krejza, J.
    NEURORADIOLOGY JOURNAL, 2012, 25 (01) : 17 - 21