Iterative denoising accelerated 3D SPACE FLAIR sequence for brain MR imaging at 3T

被引:11
作者
Eliezer, Michael [1 ,2 ]
Vaussy, Alexis [3 ]
Toupin, Solenn [3 ]
Barbe, Remy [1 ]
Kannengiesser, Stephan [4 ]
Stemmer, Alto [4 ]
Houdart, Emmanuel [1 ,2 ]
机构
[1] Lariboisiere Univ Hosp, Dept Neuroradiol, F-75010 Paris, France
[2] Univ Paris, Fac Med, F-75010 Paris, France
[3] Siemens Healthineers France, F-93210 St Denis, France
[4] Siemens Healthineers, D-91052 Erlangen, Germany
关键词
Magnetic resonance imaging (MRI); 3D FLAIR; Iterative denoising; Brain MRI; MULTIPLE-SCLEROSIS; 2D FLAIR; SUPPRESSION;
D O I
10.1016/j.diii.2021.09.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to prospectively evaluate image quality of three-dimensional fluid attenuated inversion recovery (3D-FLAIR) sequence acquired with a high acceleration factor and reconstructed with iterative denoising (ID) for brain magnetic resonance imaging (MRI) at 3-T. Material and methods: Patients with brain tumor who underwent brain MRI were consecutively included. Two 3D-FLAIR sequences were successively performed for each patient. A first conventional FLAIR acquisition (conv-FLAIR) was performed with an acceleration factor of 6. The second acquisition was performed with an increased acceleration factor of 9. Two series one without ID (acc-FLAIR) and one with ID (acc-FLAIR-ID) were reconstructed. Two neuroradiologists independently assessed image quality, deep brain nuclei visualization and white matter/gray matter (WM/GM) differentiation on a 4-point scale. Results: Thirty patients with brain tumor were consecutively included in this study. There were 16 women and 14 men with a mean age of 54 +/- 17 (SD) years (range: 22-78 years). Scanning time of Acc-FLAIR-ID and Acc-FLAIR (4 min 40 sec) was 37% shorter than that of conv-FLAIR (2 min 50 sec) (P < 0.01). Improved image quality score was significantly different for both conv-FLAIR and acc-FLAIR-ID compared to acc-FLAIR (P < 0.01 for both). WM/GM differentiation score of conv-FLAIR was not significantly different compared to accFLAIR-ID (P = 0.10). Improved WM/GM differentiation score was different for both sequences compared to acc-FLAIR (P = 0.017 and P < 0.001). Deep brain nuclei visualization score was not different between convFLAIR and acc-FLAIR-ID (P = 0.71). However, the improved deep brain nuclei visualization score was signifi-cantly different for both sequences compared to acc-FLAIR (P < 0.001 for both). Conclusion: Scanning time of 3D-FLAIR sequence using a high acceleration factor reconstructed with ID algorithm can be reduced by 37% while preserving image quality for brain MRI. (c) 2021 Societe francaise de radiologie. Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:13 / 20
页数:8
相关论文
共 28 条
[1]   Interobserver agreement issues in radiology [J].
Benchoufi, M. ;
Matzner-Lober, E. ;
Molinari, N. ;
Jannot, A-S ;
Soyer, P. .
DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2020, 101 (10) :639-641
[2]   Detection of lesions in multiple sclerosis by 2D FLAIR and single-slab 3D FLAIR sequences at 3.0 T: initial results [J].
Bink, A ;
Schmitt, M ;
Gaa, J ;
Mugler, JP ;
Lanfermann, H ;
Zanella, FE .
EUROPEAN RADIOLOGY, 2006, 16 (05) :1104-1110
[3]   Controlled aliasing in volumetric parallel imaging (2D CAIPIRINHA) [J].
Breuer, FA ;
Blaimer, M ;
Mueller, MF ;
Seiberlich, N ;
Heidemann, RM ;
Griswold, MA ;
Jakob, PM .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (03) :549-556
[4]   Multicontrast Single-Slab 3D MRI to Detect Cerebral Metastasis [J].
Chen, Weiwei ;
Wang, Liang ;
Zhu, Wenzhen ;
Xia, Liming ;
Qi, Jianpin ;
Feng, Dingyi ;
Luo, Xin .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (01) :27-32
[5]   Bulk motion-compensated DCE-MRI for functional imaging of kidneys in newborns [J].
Coll-Font, Jaume ;
Afacan, Onur ;
Chow, Jeanne S. ;
Lee, Richard S. ;
Stemmer, Alto ;
Warfield, Simon K. ;
Kurugol, Sila .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2020, 52 (01) :207-216
[6]   Glioma-grade diagnosis using in -phase and out -of -phase T1-weighted magnetic resonance imaging: A prospective study [J].
De Pardieu, M. ;
Boucebci, S. ;
Herpe, G. ;
Fauche, C. ;
Velasco, S. ;
Ingrand, P. ;
Tasu, J. -P. .
DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2020, 101 (7-8) :451-456
[7]   Accelerating Brain 3D T1-Weighted Turbo Field Echo MRI Using Compressed Sensing-Sensitivity Encoding (CS-SENSE) [J].
Duan, Yunyun ;
Zhang, Jie ;
Zhuo, Zhizheng ;
Ding, Jinli ;
Ju, Rongkai ;
Wang, Jiazheng ;
Ma, Tingting ;
Haller, Sven ;
Liu, Yong ;
Liu, Yaou .
EUROPEAN JOURNAL OF RADIOLOGY, 2020, 131
[8]   Highly accelerated real-time cardiac cine MRI using k-t SPARSE-SENSE [J].
Feng, Li ;
Srichai, Monvadi B. ;
Lim, Ruth P. ;
Harrison, Alexis ;
King, Wilson ;
Adluru, Ganesh ;
Dibella, Edward V. R. ;
Sodickson, Daniel K. ;
Otazo, Ricardo ;
Kim, Daniel .
MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (01) :64-74
[9]   Evaluation of Iterative Denoising 3-Dimensional T2-Weighted Turbo Spin Echo for the Diagnosis of Deep Infiltrating Endometriosis [J].
Florin, Marie ;
Vaussy, Alexis ;
Macron, Laurent ;
Bazot, Marc ;
Stemmer, Alto ;
Pinar, Ugo ;
Jarboui, Lamia .
INVESTIGATIVE RADIOLOGY, 2021, 56 (10) :637-644
[10]   Compressed Sensing SEMAC: 8-fold Accelerated High Resolution Metal Artifact Reduction MRI of Cobalt-Chromium Knee Arthroplasty Implants [J].
Fritz, Jan ;
Ahlawat, Shivani ;
Demehri, Shadpour ;
Thawait, Gaurav K. ;
Raithel, Esther ;
Gilson, Wesley D. ;
Nittka, Mathias .
INVESTIGATIVE RADIOLOGY, 2016, 51 (10) :666-676