Thin Domain Wide Electrode (TDWE) Phantoms for Electrical Impedance Tomography (EIT)

被引:0
|
作者
Bera, Tushar Kanti [1 ]
Chowdhury, A. [2 ]
Mandal, Hiranmoy [3 ]
Kar, Kalyan [4 ]
Halder, Animesh [5 ]
Nagaraju, J. [6 ]
机构
[1] BMS Coll Engn BMSCE, Dept Med Elect, Bangalore 560019, Karnataka, India
[2] NIT Agartala, Dept Elect & Commun Engn, Agartala 799046, India
[3] Acad Technol, Dept Appl Elect & Instrumentat Engn, Hooghly 712121, W Bengal, India
[4] Batanagar Inst Engn Management & Sci, Dept Elect Engn, Kolkata 700141, India
[5] Batanagar Inst Engn Management & Sci, Dept Elect & Commun Engn, Kolkata 700141, India
[6] Indian Inst Sci, Dept Instrumentat & Appl Phys, Bangalore 560012, Karnataka, India
关键词
Electrical Impedance Tomography (EIT); practical phantom; thin domain wide electrode (TDWE) phantoms; EIT instrumentation; image reconstruction; absolute impedance imaging; EIDORS; RECONSTRUCTION ALGORITHM; SYSTEM; DESIGN;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Electrical Impedance Tomography (EIT) is a nonlinear ill posed inverse problem which is very prone to modeling errors. 2D-EIT reconstructs the spatial distribution of the object impedance profile comparing the measurements of boundary voltage data collected from a 3D object with the calculated data generated from an absolute 2D domain in computer. As the 2D-EIT assumes current conduction in two dimensional plane of EIT electrode array, the 2D EIT systems working with a practical 3D phantom produce some error and hence the forward modeling should be modified accordingly. On the other hand, the 3D error can be reduced by using long electrodes but in long electrode system, the electrode to electrode gap (EEGR) ratio required to be maintained to attain a good sensitivity is found difficult. In this direction the thin domain wide electrode (TDWE) phantoms are proposed for electrical impedance tomography (EIT) to reduce the 3D error by maintaining the required EEGR. A LabVIEW based multifrequency EIT instrumentation has been developed and a number of TDWE phantoms with different inhomogeneity configurations have been studied. Absolute impedance images reconstructed in EIDORS, demonstrate that developed TDWE phantom improves image quality by reducing the 3D error.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Drive and measurement electrode patterns for electrode impedance tomography (EIT) imaging of neural activity in peripheral nerve
    Hope, J.
    Vanholsbeeck, F.
    McDavid, A.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (06):
  • [42] An electrical impedance tomography (EIT) multi-electrode needle-probe device for local assessment of heterogeneous tissue impeditivity
    Meroni, Davide
    Maglioli, Camilla Carpano
    Bovio, Dario
    Greco, Francesco G.
    Aliverti, Andrea
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 1385 - 1388
  • [43] CONTACT ADAPTING ELECTRODE MODEL FOR ELECTRICAL IMPEDANCE TOMOGRAPHY
    Darde, J.
    Hyvonen, N.
    Kuutela, T.
    Valkonens, T.
    SIAM JOURNAL ON APPLIED MATHEMATICS, 2022, 82 (02) : 427 - 449
  • [44] Accounting for erroneous electrode data in electrical impedance tomography
    Adler, A
    PHYSIOLOGICAL MEASUREMENT, 2004, 25 (01) : 227 - 238
  • [45] Interpolation of missing electrode data in electrical impedance tomography
    Harrach, Bastian
    INVERSE PROBLEMS, 2015, 31 (11)
  • [46] A woven electrode with convex structure for electrical impedance tomography
    Zhang, Xi
    Zhong, Yueqi
    Wang, Qi
    Dou, Chang
    TEXTILE RESEARCH JOURNAL, 2022, 92 (7-8) : 1049 - 1059
  • [47] Electrical impedance tomography with compensation for electrode positioning variations
    Blott, BH
    Daniell, GJ
    Meeson, S
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (06): : 1731 - 1739
  • [48] JUSTIFICATION OF POINT ELECTRODE MODELS IN ELECTRICAL IMPEDANCE TOMOGRAPHY
    Hanke, Martin
    Harrach, Bastian
    Hyvonen, Nuutti
    MATHEMATICAL MODELS & METHODS IN APPLIED SCIENCES, 2011, 21 (06): : 1395 - 1413
  • [49] Comparison study of line electrode and compound electrode in electrical impedance tomography
    Wang, Yan
    Sha, Hong
    Ren, Chaoshi
    DYNAMICS OF CONTINUOUS DISCRETE AND IMPULSIVE SYSTEMS-SERIES B-APPLICATIONS & ALGORITHMS, 2006, 13E : 1565 - 1568
  • [50] Images reproducibility of an Electrical Impedance Tomography (EIT) prototype.: Analysis of the EIT sensibility in rats in pathological in vivo conditions
    Gaona, A
    Aguillón, P
    Mendoza, J
    López, L
    González, E
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 2296 - 2298