Thin Domain Wide Electrode (TDWE) Phantoms for Electrical Impedance Tomography (EIT)

被引:0
|
作者
Bera, Tushar Kanti [1 ]
Chowdhury, A. [2 ]
Mandal, Hiranmoy [3 ]
Kar, Kalyan [4 ]
Halder, Animesh [5 ]
Nagaraju, J. [6 ]
机构
[1] BMS Coll Engn BMSCE, Dept Med Elect, Bangalore 560019, Karnataka, India
[2] NIT Agartala, Dept Elect & Commun Engn, Agartala 799046, India
[3] Acad Technol, Dept Appl Elect & Instrumentat Engn, Hooghly 712121, W Bengal, India
[4] Batanagar Inst Engn Management & Sci, Dept Elect Engn, Kolkata 700141, India
[5] Batanagar Inst Engn Management & Sci, Dept Elect & Commun Engn, Kolkata 700141, India
[6] Indian Inst Sci, Dept Instrumentat & Appl Phys, Bangalore 560012, Karnataka, India
关键词
Electrical Impedance Tomography (EIT); practical phantom; thin domain wide electrode (TDWE) phantoms; EIT instrumentation; image reconstruction; absolute impedance imaging; EIDORS; RECONSTRUCTION ALGORITHM; SYSTEM; DESIGN;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Electrical Impedance Tomography (EIT) is a nonlinear ill posed inverse problem which is very prone to modeling errors. 2D-EIT reconstructs the spatial distribution of the object impedance profile comparing the measurements of boundary voltage data collected from a 3D object with the calculated data generated from an absolute 2D domain in computer. As the 2D-EIT assumes current conduction in two dimensional plane of EIT electrode array, the 2D EIT systems working with a practical 3D phantom produce some error and hence the forward modeling should be modified accordingly. On the other hand, the 3D error can be reduced by using long electrodes but in long electrode system, the electrode to electrode gap (EEGR) ratio required to be maintained to attain a good sensitivity is found difficult. In this direction the thin domain wide electrode (TDWE) phantoms are proposed for electrical impedance tomography (EIT) to reduce the 3D error by maintaining the required EEGR. A LabVIEW based multifrequency EIT instrumentation has been developed and a number of TDWE phantoms with different inhomogeneity configurations have been studied. Absolute impedance images reconstructed in EIDORS, demonstrate that developed TDWE phantom improves image quality by reducing the 3D error.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Domain Shape Optimization in Electrical Impedance Tomography
    Mikulka, J.
    Dusek, J.
    Chalupa, D.
    2021 PHOTONICS & ELECTROMAGNETICS RESEARCH SYMPOSIUM (PIERS 2021), 2021, : 2155 - 2159
  • [32] 505 Electrical Impedance Tomography (EIT) Can Rapidly Detect Small Pneumothoraces
    R Bhatia
    G Schmolzer
    P G Davis
    D G Tingay
    Pediatric Research, 2010, 68 : 258 - 259
  • [33] Modeling and Simulation of Electrical Impedance Tomography (EIT) on Ventilated Patients with ARDS Lungs
    Denai, Mouloud
    Mahfouf, Mahdi
    Mills, Gary H.
    8TH IEEE INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOENGINEERING, VOLS 1 AND 2, 2008, : 676 - +
  • [34] In vivo measurements for construction an anatomical thoracic atlas for Electrical Impedance Tomography (EIT)
    Sousa, T. H. S.
    Camargo, E. D. L. B.
    Martins, A. R. C.
    Biasi, C.
    Pinto, A. C. B. C. F.
    Lima, R. G.
    2014 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC) PROCEEDINGS, 2014, : 802 - 805
  • [35] Magnetic Resonance - Electrical Impedance Tomography (MR-EIT) Research at METU
    Eyuboglu, B. Murat
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 3932 - 3935
  • [36] The use of electrical impedance tomography (EIT) to evaluate pulse rate in anaesthetised horses
    Raisis, A. L.
    Mosing, M.
    Hosgood, G. L.
    Secombe, C. J.
    Adler, A.
    Waldmann, A. D.
    VETERINARY JOURNAL, 2021, 273
  • [37] Error-Constraint Deep Learning Scheme for Electrical Impedance Tomography (EIT)
    Wang, Qi
    Zhang, Hanyu
    Li, Xiuyan
    Duan, Xiaojie
    Wang, Jianming
    Zhang, Ronghua
    Zhang, Hong
    Ma, Yanhe
    Wang, Huaxiang
    Jia, Jiabin
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [38] Electrical impedance tomography (EIT) for quantification of pulmonary edema in acute lung injury
    Trepte, Constantin J. C.
    Phillips, Charles R.
    Sola, Josep
    Adler, Andy
    Haas, Sebastian A.
    Rapin, Michael
    Boehm, Stephan H.
    Reuter, Daniel A.
    CRITICAL CARE, 2016, 20 : 6
  • [39] Distinguishability for magnetic resonance-electrical impedance tomography (MR-EIT)
    Altunel, Haluk
    Eyuboglu, B. Murat
    Koksal, Adnan
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (02): : 375 - 387