Thin Domain Wide Electrode (TDWE) Phantoms for Electrical Impedance Tomography (EIT)

被引:0
作者
Bera, Tushar Kanti [1 ]
Chowdhury, A. [2 ]
Mandal, Hiranmoy [3 ]
Kar, Kalyan [4 ]
Halder, Animesh [5 ]
Nagaraju, J. [6 ]
机构
[1] BMS Coll Engn BMSCE, Dept Med Elect, Bangalore 560019, Karnataka, India
[2] NIT Agartala, Dept Elect & Commun Engn, Agartala 799046, India
[3] Acad Technol, Dept Appl Elect & Instrumentat Engn, Hooghly 712121, W Bengal, India
[4] Batanagar Inst Engn Management & Sci, Dept Elect Engn, Kolkata 700141, India
[5] Batanagar Inst Engn Management & Sci, Dept Elect & Commun Engn, Kolkata 700141, India
[6] Indian Inst Sci, Dept Instrumentat & Appl Phys, Bangalore 560012, Karnataka, India
来源
2015 THIRD INTERNATIONAL CONFERENCE ON COMPUTER, COMMUNICATION, CONTROL AND INFORMATION TECHNOLOGY (C3IT) | 2015年
关键词
Electrical Impedance Tomography (EIT); practical phantom; thin domain wide electrode (TDWE) phantoms; EIT instrumentation; image reconstruction; absolute impedance imaging; EIDORS; RECONSTRUCTION ALGORITHM; SYSTEM; DESIGN;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Electrical Impedance Tomography (EIT) is a nonlinear ill posed inverse problem which is very prone to modeling errors. 2D-EIT reconstructs the spatial distribution of the object impedance profile comparing the measurements of boundary voltage data collected from a 3D object with the calculated data generated from an absolute 2D domain in computer. As the 2D-EIT assumes current conduction in two dimensional plane of EIT electrode array, the 2D EIT systems working with a practical 3D phantom produce some error and hence the forward modeling should be modified accordingly. On the other hand, the 3D error can be reduced by using long electrodes but in long electrode system, the electrode to electrode gap (EEGR) ratio required to be maintained to attain a good sensitivity is found difficult. In this direction the thin domain wide electrode (TDWE) phantoms are proposed for electrical impedance tomography (EIT) to reduce the 3D error by maintaining the required EEGR. A LabVIEW based multifrequency EIT instrumentation has been developed and a number of TDWE phantoms with different inhomogeneity configurations have been studied. Absolute impedance images reconstructed in EIDORS, demonstrate that developed TDWE phantom improves image quality by reducing the 3D error.
引用
收藏
页数:5
相关论文
共 62 条
[1]   Measuring soil contamination with the time domain induced polarization method using LabVIEW [J].
Alegria, F. Correa ;
Martinho, E. ;
Almeida, F. .
MEASUREMENT, 2009, 42 (07) :1082-1091
[2]   Magnetic resonance imaging of labeled T-Cells in a mouse model of multiple sclerosis [J].
Anderson, SA ;
Shukaliak-Quandt, J ;
Jordan, EK ;
Arbab, AS ;
Martin, R ;
McFarland, H ;
Frank, JA .
ANNALS OF NEUROLOGY, 2004, 55 (05) :654-659
[3]   Linear filtering of 2-D wavelet coefficients for denoising ultrasound medical images [J].
Andria, G. ;
Attivissimo, F. ;
Cavone, G. ;
Giaquinto, N. ;
Lanzolla, A. M. L. .
MEASUREMENT, 2012, 45 (07) :1792-1800
[4]   A statistical approach for MR and CT images comparison [J].
Andria, Gregorio ;
Attivissimo, Filippo ;
Lanzolla, Anna Maria Lucia .
MEASUREMENT, 2013, 46 (01) :57-65
[5]  
[Anonymous], 1993, CLIN PHYSL APPL ELEC
[6]  
[Anonymous], 2012, LECT NOTES COMPUTER, DOI DOI 10.1007/978-3-642-29280-4_112011
[7]  
Bera T. K., 2011, Proceedings of the 2011 World Congress on Information and Communication Technologies (WICT), P1346, DOI 10.1109/WICT.2011.6141444
[8]  
Bera Tushar Kanti, 2009, 2009 IEEE Instrumentation and Measurement Technology Conference (I2MTC), P511, DOI 10.1109/IMTC.2009.5168503
[9]  
Bera T.K., 2010, P IEEE INT C SYST ME, P290, DOI DOI 10.1109/ICSMB.2010.5735387
[10]  
Bera T. K., 2013, 2013 4 INT C COMP