What is the ideal off-test trial for continuous-flow ventricular-assist-device explantation? Intracircuit back-flow analysis in a mock circulation model

被引:18
作者
Ando, Masahiko [1 ,2 ]
Nishimura, Takashi [3 ]
Takewa, Yoshiaki [1 ]
Ogawa, Daisuke [6 ]
Yamazaki, Kenji [5 ]
Kashiwa, Koichi [4 ]
Kyo, Shunei [3 ]
Ono, Minoru [2 ]
Taenaka, Yoshiyuki [1 ]
Tatsumi, Eisuke [1 ]
机构
[1] Natl Cardiovasc Ctr, Dept Artificial Organ, Res Inst, Osaka 5658565, Japan
[2] Univ Tokyo, Dept Cardiothorac Surg, Bunkyo Ku, Tokyo 1138655, Japan
[3] Univ Tokyo, Dept Therapeut Strategy Heart Failure, Bunkyo Ku, Tokyo 1138655, Japan
[4] Tokyo Univ Hosp, Dept Med Engn, Bunkyo Ku, Tokyo 1138655, Japan
[5] Tokyo Womens Med Univ, Dept Cardiovasc Surg, Shinjuku Ku, Tokyo 1628666, Japan
[6] Sun Med Technol Res Corp, Nagano 3920012, Japan
关键词
Left-ventricular-assist device; Bridge to recovery; Mock circulation model; SAFETY; HEART; PUMP;
D O I
10.1007/s10047-010-0543-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Bridge to recovery has become a major goal after left-ventricular-assist-device (LVAD) implantation thanks to recent development in adjunctive therapies. Precise assessment of native heart function under minimum LVAD support is the key for successful LVAD explantation. However, weaning of centrifugal LVADs normally generates diastolic intracircuit backward flow. This retrograde flow may become excessive load for the native heart during off-pump test. The flow itself is an inevitable characteristic of centrifugal pumps. Therefore, evaluating this retrograde flow in vitro is of considerable significance, even if its amount is different from that in clinical settings. The purpose of this study was to assess diastolic backflow of continuous-flow centrifugal LVADs in a mock circulation model. A centrifugal LVAD (EVAHEART, Sun Medical Technology) was installed in a mock circulation model by the left ventricle uptake and the ascending aortic return. Pump flow was measured at the pump rotational speed of 1000, 1500, 2000, and 2500 rpm, and pulse rate of the virtual native heart was varied to 60, 90, and 120 beats/min. After data collection, pump flow was integrated, and forward and backward intracircuit flow were calculated. As a result, nonphysiological reverse flow of approximately 2.0 L/min exists at the rotational speed, providing 0 L/min mean pump flow. An ideal off-test trial condition should be realizing both +/- 0 L/min pump flow and no intracircuit backward flow at the same time. We are developing a novel EVAHEART drive mode that can change its rotational speed in synchronization with cardiac cycle with the aim of controlling this retrograde flow with the new drive mode and creating an ideal off-test condition.
引用
收藏
页码:70 / 73
页数:4
相关论文
共 6 条
[1]   Left ventricular assist device and drug therapy for the reversal of heart failure [J].
Birks, Emma J. ;
Tansley, Patrick D. ;
Hardy, James ;
George, Robert S. ;
Bowles, Christopher T. ;
Burke, Margaret ;
Banner, Nicholas R. ;
Khaghani, Asghar ;
Yacoub, Magdi H. .
NEW ENGLAND JOURNAL OF MEDICINE, 2006, 355 (18) :1873-1884
[2]   Hemodynamics and patient safety during pump-off studies of an axial-flow left ventricular assist device [J].
Myers, TJ ;
Frazier, OH ;
Mesina, HS ;
Radovancevic, B ;
Gregoric, ID .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2006, 25 (04) :379-383
[3]  
Osaki Satoru, 2009, Congest Heart Fail, V15, P58
[4]   The safety system for the rotary blood pump, combination of the valve and LVAD pulsatile mode: In vitro test [J].
Tayama, E ;
Ohashi, Y ;
Niimi, Y ;
Takami, Y ;
Ohtsuka, G ;
Nakata, K ;
Benkowski, R ;
Glueck, JA ;
Nose, Y .
ARTIFICIAL ORGANS, 1998, 22 (04) :342-345
[5]   How to ensure safety factors in the development of artificial heart: Verified by the usage of "Modeling and simulation" technology [J].
Umezu, Mitsuo .
Life System Modeling and Simulation, Proceedings, 2007, 4689 :88-96
[6]   EVAHEART™: An implantable centrifugal blood pump for long-term circulatory support [J].
Kenji Yamazaki ;
Shinichiro Kihara ;
Takehide Akimoto ;
Osamu Tagusari ;
Akihiko Kawai ;
Mitsuo Umezu ;
Jun Tomioka ;
Robert L. Kormos ;
Bartley P. Griffith ;
Hiromi Kurosawa .
The Japanese Journal of Thoracic and Cardiovascular Surgery, 2002, 50 (11) :461-465