RARE two-point Dixon with dual bandwidths

被引:2
作者
Ryden, Henric [1 ,2 ]
Berglund, Johan [2 ]
Norbeck, Ola [1 ,2 ]
Avventi, Enrico [1 ,2 ]
Sprenger, Tim [2 ,3 ]
van Niekerk, Adam [2 ]
Skare, Stefan [1 ,2 ]
机构
[1] Karolinska Univ Hosp, Dept Neuroradiol, Stockholm, Sweden
[2] Karolinska Inst, Dept Clin Neurosci, Stockholm, Sweden
[3] GE Healthcare, Munich, Germany
关键词
chemical shift; Cramer-Rao bound; Dixon; Monte Carlo; NSA; RARE; FAT; ECHO; WATER; DECOMPOSITION; ACQUISITION; SEPARATION; INVERSION; MRI;
D O I
10.1002/mrm.28293
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To investigate the impact of dual readout bandwidths (dBW) in a dual echo fat/water acquisition and describe a dBW-rapid acquisition relaxation enhanced, or turbo spin echo sequence where the concept is used to improve SNR by removing dead times between refocusing pulses and avoiding redundant Chemical-shift encoded. Methods Cramer-Rao bounds and Monte Carlo simulations were used to investigate a two-point fat/water model where the difference in bandwidths is incorporated. In vivo images were acquired at 1.5 and 3 T with the dBW-rapid acquisition relaxation enhanced, or turbo spin echo sequence. Typical bandwidth ratios were 1:2. SNR was compared with a single bandwidth sequence under identical scan parameters at 3T. Results Monte Carlo simulations and Cramer-Rao analysis demonstrate that number of signal averages can be improved with dual bandwidths compared to conventional single bandwidth acquisitions. The dBW-rapid acquisition relaxation enhanced, or turbo spin echo sequence can acquire images with high readout resolutions with well-conditioned sampling. An SNR improvement of 52% was measured, in line with the theoretical gain of 54%. Conclusions The proposed dBW-rapid acquisition relaxation enhanced, or turbo spin echo sequence is a highly SNR-efficient two-point rapid acquisition relaxation enhanced, or turbo spin echo sequence without dead times, and can acquire images at higher resolutions than current vendor-supplied alternatives.
引用
收藏
页码:2456 / 2468
页数:13
相关论文
共 50 条
[31]   Comparison of T1-weighted 2D TSE, 3D SPGR, and two-point 3D Dixon MRI for automated segmentation of visceral adipose tissue at 3 Tesla [J].
Fallah, Faezeh ;
Machann, Juergen ;
Martirosian, Petros ;
Bamberg, Fabian ;
Schick, Fritz ;
Yang, Bin .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2017, 30 (02) :139-151
[32]   Two-point wavepacket modelling of jet noise [J].
Maia, I. A. ;
Jordan, P. ;
Cavalieri, A. V. G. ;
Jaunet, V. .
PROCEEDINGS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2019, 475 (2227)
[33]   Fat suppression for ultrashort echo time imaging using a single-point Dixon method [J].
Jang, Hyungseok ;
Carl, Michael ;
Ma, Yajun ;
Jerban, Saeed ;
Guo, Tan ;
Zhao, Wei ;
Chang, Eric Y. ;
Du, Jiang .
NMR IN BIOMEDICINE, 2019, 32 (05)
[34]   Use of two-point and six-point Dixon MRI for fat fraction analysis in the lumbar vertebral bodies and paraspinal muscles in healthy dogs: comparison with magnetic resonance spectroscopy [J].
Lee, Hye-Won ;
Lee, Ji-Yun ;
Lee, Joo-Young ;
Yu, Seung-Man ;
Lee, Kija ;
Lee, Sang-Kwon .
FRONTIERS IN VETERINARY SCIENCE, 2024, 11
[35]   Two-point correlation function for the triangular Ising antiferromagnet [J].
Wojtas, David H. ;
Millane, R. P. .
PHYSICAL REVIEW E, 2009, 79 (04)
[36]   Spherical means on two-point homogeneous spaces and applications [J].
Volchkov, V. V. ;
Volchkov, Vit. V. .
IZVESTIYA MATHEMATICS, 2013, 77 (02) :223-252
[37]   Automated two-point dixon screening for the evaluation of hepatic steatosis and siderosis: comparison with R2*-relaxometry and chemical shift-based sequences [J].
B. Henninger ;
H. Zoller ;
S. Rauch ;
M. Schocke ;
S. Kannengiesser ;
X. Zhong ;
G. Reiter ;
W. Jaschke ;
C. Kremser .
European Radiology, 2015, 25 :1356-1365
[38]   Two point Dixon-based chemical exchange saturation transfer (CEST) MRI in renal transplant patients on 3 T [J].
Stabinska, Julia ;
Mueller-Lutz, Anja ;
Wittsack, Hans-Jorg ;
Tell, Christian ;
Rump, Lars Christian ;
Ertas, Neslihan ;
Antoch, Gerald ;
Ljimani, Alexandra .
MAGNETIC RESONANCE IMAGING, 2022, 90 :61-69
[39]   Two-point particle tracking microrheology of nematic complex fluids [J].
Gomez-Gonzalez, Manuel ;
del Alamo, Juan C. .
SOFT MATTER, 2016, 12 (26) :5758-5779
[40]   A virtual parallel two-point roundness error measurement system [J].
Chai, Ning ;
Yin, Ziqiang ;
Yao, Jianhua ;
Meng, Songtao ;
Weng, Chuan ;
Duan, Bin .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2021, 32 (11)