RARE two-point Dixon with dual bandwidths

被引:2
|
作者
Ryden, Henric [1 ,2 ]
Berglund, Johan [2 ]
Norbeck, Ola [1 ,2 ]
Avventi, Enrico [1 ,2 ]
Sprenger, Tim [2 ,3 ]
van Niekerk, Adam [2 ]
Skare, Stefan [1 ,2 ]
机构
[1] Karolinska Univ Hosp, Dept Neuroradiol, Stockholm, Sweden
[2] Karolinska Inst, Dept Clin Neurosci, Stockholm, Sweden
[3] GE Healthcare, Munich, Germany
关键词
chemical shift; Cramer-Rao bound; Dixon; Monte Carlo; NSA; RARE; FAT; ECHO; WATER; DECOMPOSITION; ACQUISITION; SEPARATION; INVERSION; MRI;
D O I
10.1002/mrm.28293
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To investigate the impact of dual readout bandwidths (dBW) in a dual echo fat/water acquisition and describe a dBW-rapid acquisition relaxation enhanced, or turbo spin echo sequence where the concept is used to improve SNR by removing dead times between refocusing pulses and avoiding redundant Chemical-shift encoded. Methods Cramer-Rao bounds and Monte Carlo simulations were used to investigate a two-point fat/water model where the difference in bandwidths is incorporated. In vivo images were acquired at 1.5 and 3 T with the dBW-rapid acquisition relaxation enhanced, or turbo spin echo sequence. Typical bandwidth ratios were 1:2. SNR was compared with a single bandwidth sequence under identical scan parameters at 3T. Results Monte Carlo simulations and Cramer-Rao analysis demonstrate that number of signal averages can be improved with dual bandwidths compared to conventional single bandwidth acquisitions. The dBW-rapid acquisition relaxation enhanced, or turbo spin echo sequence can acquire images with high readout resolutions with well-conditioned sampling. An SNR improvement of 52% was measured, in line with the theoretical gain of 54%. Conclusions The proposed dBW-rapid acquisition relaxation enhanced, or turbo spin echo sequence is a highly SNR-efficient two-point rapid acquisition relaxation enhanced, or turbo spin echo sequence without dead times, and can acquire images at higher resolutions than current vendor-supplied alternatives.
引用
收藏
页码:2456 / 2468
页数:13
相关论文
共 50 条
  • [1] Thrombus-Mimicking Artifacts in Two-Point Dixon MRI: Prevalence, Appearance, and Severity
    Schubert, Tilman
    Bannas, Peter
    Kinner, Sonja
    Sharma, Samir
    Holmes, James H.
    Rahimi, Mahdi Salmani
    Korosec, Frank R.
    Reeder, Scott B.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 45 (01) : 229 - 236
  • [2] Two-point Dixon fat-water swapping artifact: lesion mimicker at musculoskeletal T2-weighted MRI
    Kirchgesner, Thomas
    Acid, Souad
    Perlepe, Vasiliki
    Lecouvet, Frederic
    Vande Berg, Bruno
    SKELETAL RADIOLOGY, 2020, 49 (12) : 2081 - 2086
  • [3] Improved nerve conspicuity with water-weighting and denoising in two-point Dixon magnetic resonance neurography
    Tan, Ek T.
    Queler, Sophie C.
    Lin, Bin
    Endo, Yoshimi
    Burge, Alissa J.
    Sternberg, Julia
    Potter, Hollis G.
    Sneag, Darryl B.
    MAGNETIC RESONANCE IMAGING, 2021, 79 : 103 - 111
  • [4] Two-point Dixon Method With Flexible Echo Times
    Berglund, Johan
    Ahlstroem, Hakan
    Johansson, Lars
    Kullberg, Joel
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (04) : 994 - 1004
  • [5] Two-Point Dixon Technique Provides Robust Fat Suppression for Multi-Mouse Imaging
    Ragan, Dustin K.
    Bankson, James A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (02) : 510 - 514
  • [6] Two-point Dixon fat-water swapping artifact: lesion mimicker at musculoskeletal T2-weighted MRI
    Thomas Kirchgesner
    Souad Acid
    Vasiliki Perlepe
    Frédéric Lecouvet
    Bruno Vande Berg
    Skeletal Radiology, 2020, 49 : 2081 - 2086
  • [7] Improved T1, Contrast Concentration, and Pharmacokinetic Parameter Quantification in the Presence of Fat with Two-Point Dixon for Dynamic Contrast-Enhanced Magnetic Resonance Imaging
    Le, Yuan
    Dale, Brian
    Akisik, Fatih
    Koons, Karen
    Lin, Chen
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (04) : 1677 - 1684
  • [8] Effectiveness of a three-dimensional dual gradient echo two-point Dixon technique for the characterization of adrenal lesions at 3 Tesla
    Marin, Daniele
    Dale, Brian M.
    Bashir, Mustafa R.
    Ziemlewicz, Timothy J.
    Ringe, Kristina I.
    Boll, Daniel T.
    Merkle, Elmar M.
    EUROPEAN RADIOLOGY, 2012, 22 (01) : 259 - 268
  • [9] Direct water and fat determination in two-point Dixon imaging with flexible echo times
    Rambow, Olen
    Hazle, John
    Clark, John
    Ma, Jingfei
    MEDICAL PHYSICS, 2013, 40 (11)
  • [10] Two-point dixon technique for water-fat signal decomposition with B-o inhomogeneity correction
    Coombs, BD
    Szumowski, J
    Coshow, W
    MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (06) : 884 - 889