An international intercomparison on "self-calibrated" alanine EPR dosimeters

被引:12
作者
Gancheva, V. [1 ]
Yordanov, N. D. [1 ]
Callens, F. [2 ]
Vanhaelewyn, G. [2 ]
Raffi, J. [3 ,4 ]
Bortolin, E. [5 ]
Onori, S. [5 ]
Malinen, E. [6 ]
Sagstuen, E. [6 ]
Fabislak, S. [7 ]
Peimel-Stuglik, Z. [7 ]
机构
[1] Bulgarian Acad Sci, Inst Catalysis, Lab EPR, BU-1113 Sofia, Bulgaria
[2] Univ Ghent, Dept Solid State Sci, B-9000 Ghent, Belgium
[3] Fac Sci & Tech St Jerome, UMR 6171, LRMO 461, F-13397 Marseille 20, France
[4] Fac Sci & Tech St Jerome, CEA, F-13397 Marseille 20, France
[5] Ist Super Sanita, Dept Technol & Hlth, I-00161 Rome, Italy
[6] Univ Oslo, Dept Phys, N-0316 Oslo, Norway
[7] Inst Nucl Chem & Technol, Lab Measurements Technol Doses, PL-03195 Warsaw, Poland
关键词
alanine; self-calibrated" dosimeters; gamma-irradiation; EPR dosimetry; intercomparison;
D O I
10.1016/j.radphyschem.2007.06.004
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The results, obtained by six independent electron paramagnetic resonance (EPR) laboratories, of the dose response coefficients (K-dr) of "self-calibrated" solid-state EPR dosimeters containing alanine as a radiation-sensitive material and Mn2+/MgO as an internal reference material, are reported. The intercomparison trial was divided into three steps. It started with the distribution of dosimeters among the participating EPR laboratories with the purpose of irradiating them with known doses of x-rays and to estimate the K-dr. The percentage standard deviation (PSD) of the K-dr obtained at individual labs was in the range of 1.4-4.6%. The interlaboratory PSD of the K-dr was 8%, primarily pointing to variations in irradiation procedures and EPR spectrometer settings. Further investigations showed that the main source of the interlaboratory PSD is differences in the calibrations of irradiators and settings of EPR acquisition parameters. In order to provide reproducible estimates of the K-dr, low microwave power and modulation amplitude using a combination of sweep time and time constant that gives a distortion-free EPR spectrum should be utilized. In the third step following such a procedure, measuring the same irradiated alanine dosimeter at the respective laboratories, spectrometers (12 instruments of 6 different models and 3 producers) and 10 operators gave an interlaboratory PSD of 3.1%. In conclusion, EPR dosimetry using "self-calibrated" alanine dosimeters may be used as a secondary standard, although a careful calibration of the EPR spectrometer must be performed in order to further reduce the uncertainty. (C) 2007 Published by Elsevier Ltd.
引用
收藏
页码:357 / 364
页数:8
相关论文
共 31 条
[1]  
BOGUSHEVICH S, 1996, ZH PRIKL SPEKTROSK, V63, P258
[2]   Inorganic EPR dosimeter for medical radiology [J].
Bogushevich, SE ;
Ugolev, II .
APPLIED RADIATION AND ISOTOPES, 2000, 52 (05) :1217-1219
[3]   EPR study of light illumination effects on radicals in gamma-irradiated L-alanine [J].
Ciesielski, B ;
Schultka, K ;
Penkowski, M ;
Sagstuen, E .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2004, 60 (06) :1327-1333
[4]   e-calibrations:: using the Internet to deliver calibration services in real time at lower cost [J].
Desrosiers, M ;
Nagy, V ;
Puhl, J ;
Glenn, R ;
Densock, R ;
Stieren, D ;
Lang, B ;
Kamlowski, A ;
Maier, D ;
Heiss, A .
RADIATION PHYSICS AND CHEMISTRY, 2002, 63 (3-6) :759-763
[5]   Next-generation services for e-traceability to ionizing radiation national standards [J].
Desrosiers, MF ;
Klemick, M ;
Puhl, JM ;
Uchida, D ;
Mallis, S .
RADIATION PHYSICS AND CHEMISTRY, 2004, 71 (1-2) :371-374
[6]   ESR and optical absorption studies of gamma- and electron-irradiated sugar crystals [J].
Flores, C ;
Cabrera, E ;
Calderón, T ;
Muñoz, E ;
Adem, E ;
Hernández, J ;
Boldú, J ;
Ovalle, P ;
Murrieta, H .
APPLIED RADIATION AND ISOTOPES, 2000, 52 (05) :1229-1234
[7]   APPLICATIONS OF SOME POLYCRYSTALLINE HYDROCARBONS (ALANINE AND SUGARS) FOR HIGH-DOSE MEASUREMENT BY ESR SPECTROMETRY [J].
GENERALOVA, VV ;
GROMOV, AA ;
GURSKY, MN ;
ZHANZHORA, AP ;
ILGASOVA, NP ;
LESKOV, AS .
APPLIED RADIATION AND ISOTOPES, 1993, 44 (04) :791-793
[8]   Ammonium formate, a compound for sensitive EPR dosimetry [J].
Gustafsson, H ;
Olsson, S ;
Lund, A ;
Lund, E .
RADIATION RESEARCH, 2004, 161 (04) :464-470
[9]   New materials for ESR dosimetry [J].
Lund, A ;
Olsson, S ;
Bonora, M ;
Lund, E ;
Gustafsson, H .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2002, 58 (06) :1301-1311
[10]   High-dose standardization service of the IAEA [J].
Mehta, K .