Impact of inter-reader contouring variability on textural radiomics of colorectal liver metastases

被引:34
作者
Rizzetto, Francesco [1 ]
Calderoni, Francesca [2 ]
De Mattia, Cristina [2 ]
Defeudis, Arianna [3 ,4 ]
Giannini, Valentina [3 ,4 ]
Mazzetti, Simone [3 ,4 ]
Vassallo, Lorenzo [5 ]
Ghezzi, Silvia [6 ]
Sartore-Bianchi, Andrea [6 ,7 ]
Marsoni, Silvia [8 ]
Siena, Salvatore [6 ,7 ]
Regge, Daniele [3 ,4 ]
Torresin, Alberto [2 ,9 ]
Vanzulli, Angelo [1 ,7 ]
机构
[1] ASST Grande Osped Metropolitano Niguarda, Dept Radiol, Piazza Osped Maggiore 3, I-20162 Milan, Italy
[2] ASST Grande Osped Metropolitano Niguarda, Dept Med Phys, Piazza Osped Maggiore 3, I-20162 Milan, Italy
[3] Univ Turin, Dept Surg Sci, Via Verdi 8, I-10124 Turin, Italy
[4] FPO IRCCS, Radiol Unit, Candiolo Canc Inst, Str Prov 142 Km 3-95, I-10060 Turin, Italy
[5] SS Annunziata Hosp ASLCN1 Cuneo, Radiol Unit, Via Osped 14, I-12038 Cuneo, Savigliano, Italy
[6] Grande Osped Metropolitano Niguarda, Niguarda Canc Ctr, Piazza Osped Maggiore 3, I-20162 Milan, Italy
[7] Univ Milan, Dept Oncol & Hematooncol, Via Festa Perdono 7, I-20122 Milan, Italy
[8] IFOM FIRC Inst Mol Oncol, Precis Oncol, Via Adamello 16, I-20139 Milan, Italy
[9] Univ Milan, Dept Phys, Via Giovanni Celoria 16, I-20133 Milan, Italy
关键词
Colorectal neoplasms; Image processing (computer-assisted); Liver neoplasms; Radiomics; Tomography (x-ray; computed); TUMOR HETEROGENEITY; COMPUTED-TOMOGRAPHY; CT SCANS; SEGMENTATION; FEATURES; RELIABILITY; DELINEATION; STABILITY; SIZE; 2D;
D O I
10.1186/s41747-020-00189-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Radiomics is expected to improve the management of metastatic colorectal cancer (CRC). We aimed at evaluating the impact of liver lesion contouring as a source of variability on radiomic features (RFs). Methods After Ethics Committee approval, 70 liver metastases in 17 CRC patients were segmented on contrast-enhanced computed tomography scans by two residents and checked by experienced radiologists. RFs from grey level co-occurrence and run length matrices were extracted from three-dimensional (3D) regions of interest (ROIs) and the largest two-dimensional (2D) ROIs. Inter-reader variability was evaluated with Dice coefficient and Hausdorff distance, whilst its impact on RFs was assessed using mean relative change (MRC) and intraclass correlation coefficient (ICC). For the main lesion of each patient, one reader also segmented a circular ROI on the same image used for the 2D ROI. Results The best inter-reader contouring agreement was observed for 2D ROIs according to both Dice coefficient (median 0.85, interquartile range 0.78-0.89) and Hausdorff distance (0.21 mm, 0.14-0.31 mm). Comparing RF values, MRC ranged 0-752% for 2D and 0-1567% for 3D. For 24/32 RFs (75%), MRC was lower for 2D than for 3D. An ICC > 0.90 was observed for more RFs for 2D (53%) than for 3D (34%). Only 2/32 RFs (6%) showed a variability between 2D and circular ROIs higher than inter-reader variability. Conclusions A 2D contouring approach may help mitigate overall inter-reader variability, albeit stable RFs can be extracted from both 3D and 2D segmentations of CRC liver metastases.
引用
收藏
页数:12
相关论文
共 45 条
[11]   Impact of image preprocessing on the volume dependence and prognostic potential of radiomics features in non-small cell lung cancer [J].
Fave, Xenia ;
Zhang, Lifei ;
Yang, Jinzhong ;
Mackin, Dennis ;
Balter, Peter ;
Gomez, Daniel ;
Followill, David ;
Jones, A. Kyle ;
Stingo, Francesco ;
Court, Laurence E. .
TRANSLATIONAL CANCER RESEARCH, 2016, 5 (04) :349-363
[12]  
Ferlay J., 2018, Global cancer observatory: cancer today, V3, P2019
[13]   How clinical imaging can assess cancer biology [J].
Garcia-Figueiras, Roberto ;
Baleato-Gonzalez, Sandra ;
Padhani, Anwar R. ;
Luna-Alcala, Antonio ;
Antonio Vallejo-Casas, Juan ;
Sala, Evis ;
Vilanova, Joan C. ;
Koh, Dow-Mu ;
Herranz-Carnero, Michel ;
Alberto Vargas, Herbert .
INSIGHTS INTO IMAGING, 2019, 10 (01)
[14]   Radiomics: Images Are More than Pictures, They Are Data [J].
Gillies, Robert J. ;
Kinahan, Paul E. ;
Hricak, Hedvig .
RADIOLOGY, 2016, 278 (02) :563-577
[15]   Radiomics in Pulmonary Lesion Imaging [J].
Hassani, Cameron ;
Varghese, Bino A. ;
Nieva, Jorge ;
Duddalwar, Vinay .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 212 (03) :497-504
[16]   Reliability of Single-Slice-Based 2D CT Texture Analysis of Renal Masses: Influence of Intra- and Interobserver Manual Segmentation Variability on Radiomic Feature Reproducibility [J].
Kocak, Burak ;
Durmaz, Emine Sebnem ;
Kaya, Ozlem Korkmaz ;
Ates, Ece ;
Kilickesmez, Ozgur .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 213 (02) :377-383
[17]   A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research [J].
Koo, Terry K. ;
Li, Mae Y. .
JOURNAL OF CHIROPRACTIC MEDICINE, 2016, 15 (02) :155-163
[18]   Radiomics: the process and the challenges [J].
Kumar, Virendra ;
Gu, Yuhua ;
Basu, Satrajit ;
Berglund, Anders ;
Eschrich, Steven A. ;
Schabath, Matthew B. ;
Forster, Kenneth ;
Aerts, Hugo J. W. L. ;
Dekker, Andre ;
Fenstermacher, David ;
Goldgof, Dmitry B. ;
Hall, Lawrence O. ;
Lambin, Philippe ;
Balagurunathan, Yoganand ;
Gatenby, Robert A. ;
Gillies, Robert J. .
MAGNETIC RESONANCE IMAGING, 2012, 30 (09) :1234-1248
[19]   Radiomics: the bridge between medical imaging and personalized medicine [J].
Lambin, Philippe ;
Leijenaar, Ralph T. H. ;
Deist, Timo M. ;
Peerlings, Jurgen ;
de Jong, Evelyn E. C. ;
van Timmeren, Janita ;
Sanduleanu, Sebastian ;
Larue, Ruben T. H. M. ;
Even, Aniek J. G. ;
Jochems, Arthur ;
van Wijk, Yvonka ;
Woodruff, Henry ;
van Soest, Johan ;
Lustberg, Tim ;
Roelofs, Erik ;
van Elmpt, Wouter ;
Dekker, Andre ;
Mottaghy, Felix M. ;
Wildberger, Joachim E. ;
Walsh, Sean .
NATURE REVIEWS CLINICAL ONCOLOGY, 2017, 14 (12) :749-762
[20]   Liver metastases: Detection and staging [J].
Lincke, Therese ;
Zech, Christoph J. .
EUROPEAN JOURNAL OF RADIOLOGY, 2017, 97 :76-82