Impact of inter-reader contouring variability on textural radiomics of colorectal liver metastases

被引:34
作者
Rizzetto, Francesco [1 ]
Calderoni, Francesca [2 ]
De Mattia, Cristina [2 ]
Defeudis, Arianna [3 ,4 ]
Giannini, Valentina [3 ,4 ]
Mazzetti, Simone [3 ,4 ]
Vassallo, Lorenzo [5 ]
Ghezzi, Silvia [6 ]
Sartore-Bianchi, Andrea [6 ,7 ]
Marsoni, Silvia [8 ]
Siena, Salvatore [6 ,7 ]
Regge, Daniele [3 ,4 ]
Torresin, Alberto [2 ,9 ]
Vanzulli, Angelo [1 ,7 ]
机构
[1] ASST Grande Osped Metropolitano Niguarda, Dept Radiol, Piazza Osped Maggiore 3, I-20162 Milan, Italy
[2] ASST Grande Osped Metropolitano Niguarda, Dept Med Phys, Piazza Osped Maggiore 3, I-20162 Milan, Italy
[3] Univ Turin, Dept Surg Sci, Via Verdi 8, I-10124 Turin, Italy
[4] FPO IRCCS, Radiol Unit, Candiolo Canc Inst, Str Prov 142 Km 3-95, I-10060 Turin, Italy
[5] SS Annunziata Hosp ASLCN1 Cuneo, Radiol Unit, Via Osped 14, I-12038 Cuneo, Savigliano, Italy
[6] Grande Osped Metropolitano Niguarda, Niguarda Canc Ctr, Piazza Osped Maggiore 3, I-20162 Milan, Italy
[7] Univ Milan, Dept Oncol & Hematooncol, Via Festa Perdono 7, I-20122 Milan, Italy
[8] IFOM FIRC Inst Mol Oncol, Precis Oncol, Via Adamello 16, I-20139 Milan, Italy
[9] Univ Milan, Dept Phys, Via Giovanni Celoria 16, I-20133 Milan, Italy
关键词
Colorectal neoplasms; Image processing (computer-assisted); Liver neoplasms; Radiomics; Tomography (x-ray; computed); TUMOR HETEROGENEITY; COMPUTED-TOMOGRAPHY; CT SCANS; SEGMENTATION; FEATURES; RELIABILITY; DELINEATION; STABILITY; SIZE; 2D;
D O I
10.1186/s41747-020-00189-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Radiomics is expected to improve the management of metastatic colorectal cancer (CRC). We aimed at evaluating the impact of liver lesion contouring as a source of variability on radiomic features (RFs). Methods After Ethics Committee approval, 70 liver metastases in 17 CRC patients were segmented on contrast-enhanced computed tomography scans by two residents and checked by experienced radiologists. RFs from grey level co-occurrence and run length matrices were extracted from three-dimensional (3D) regions of interest (ROIs) and the largest two-dimensional (2D) ROIs. Inter-reader variability was evaluated with Dice coefficient and Hausdorff distance, whilst its impact on RFs was assessed using mean relative change (MRC) and intraclass correlation coefficient (ICC). For the main lesion of each patient, one reader also segmented a circular ROI on the same image used for the 2D ROI. Results The best inter-reader contouring agreement was observed for 2D ROIs according to both Dice coefficient (median 0.85, interquartile range 0.78-0.89) and Hausdorff distance (0.21 mm, 0.14-0.31 mm). Comparing RF values, MRC ranged 0-752% for 2D and 0-1567% for 3D. For 24/32 RFs (75%), MRC was lower for 2D than for 3D. An ICC > 0.90 was observed for more RFs for 2D (53%) than for 3D (34%). Only 2/32 RFs (6%) showed a variability between 2D and circular ROIs higher than inter-reader variability. Conclusions A 2D contouring approach may help mitigate overall inter-reader variability, albeit stable RFs can be extracted from both 3D and 2D segmentations of CRC liver metastases.
引用
收藏
页数:12
相关论文
共 45 条
[1]   Beyond imaging: The promise of radiomics [J].
Avanzo, Michele ;
Stancanello, Joseph ;
El Naqa, Issam .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 38 :122-139
[2]   CT texture analysis in colorectal liver metastases and the surrounding liver parenchyma and its potential as an imaging biomarker of disease aggressiveness, response and survival [J].
Beckers, R. C. J. ;
Trebeschi, S. ;
Maas, M. ;
Schnerr, R. S. ;
Sijmons, J. M. L. ;
Beets, G. L. ;
Houwers, J. B. ;
Beets-Tan, R. G. H. ;
Lambregts, D. M. J. .
EUROPEAN JOURNAL OF RADIOLOGY, 2018, 102 :15-21
[3]  
Bellon MR, 2014, J RADIOSURGERY SBRT, V3, P149
[4]  
Bilic P, 2019, ARXIV PREPRINT ARXIV
[5]   A (p, q)-Averaged Hausdorff Distance for Arbitrary Measurable Sets [J].
Bogoya, Johan M. ;
Vargas, Andres ;
Cuate, Oliver ;
Schuetze, Oliver .
MATHEMATICAL AND COMPUTATIONAL APPLICATIONS, 2018, 23 (03)
[6]   Computational resources for radiomics [J].
Court, Laurence E. ;
Fave, Xenia ;
Mackin, Dennis ;
Lee, Joonsang ;
Yang, Jinzhong ;
Zhang, Lifei .
TRANSLATIONAL CANCER RESEARCH, 2016, 5 (04) :340-348
[7]   Standardization of CT radiomics features for multi-center analysis: impact of software settings and parameters [J].
Defeudis, Arianna ;
De Mattia, Cristina ;
Rizzetto, Francesco ;
Calderoni, Francesca ;
Mazzetti, Simone ;
Torresin, Alberto ;
Vanzulli, Angelo ;
Regge, Daniele ;
Giannini, Valentina .
PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (19)
[8]   MEASURES OF THE AMOUNT OF ECOLOGIC ASSOCIATION BETWEEN SPECIES [J].
DICE, LR .
ECOLOGY, 1945, 26 (03) :297-302
[9]   Early evaluation using a radiomic signature of unresectable hepatic metastases to predict outcome in patients with colorectal cancer treated with FOLFIRI and bevacizumab [J].
Dohan, Anthony ;
Gallix, Benoit ;
Guiu, Boris ;
Le Malicot, Karine ;
Reinhold, Caroline ;
Soyer, Philippe ;
Bennouna, Jaafar ;
Ghiringhelli, Francois ;
Barbier, Emilie ;
Boige, Valerie ;
Taieb, Julien ;
Bouche, Olivier ;
Francois, Eric ;
Phelip, Jean-Marc ;
Borel, Christian ;
Faroux, Roger ;
Seitz, Jean-Francois ;
Jacquot, Stephane ;
Ben Abdelghani, Meher ;
Khemissa-Akouz, Faiza ;
Genet, Dominique ;
Jouve, Jean Louis ;
Rinaldi, Yves ;
Desseigne, Francoise ;
Texereau, Patrick ;
Suc, Etienne ;
Lepage, Come ;
Aparicio, Thomas ;
Hoeffel, Christine .
GUT, 2020, 69 (03) :531-539
[10]  
Evans JD., 1996, Straightforward statistics for the behavioral sciences