Time transfer using an asynchronous computer network:: Results from three weeks of measurements

被引:2
作者
Ebenhag, S. C. [1 ]
Jaldehag, K. [1 ]
Hedekvist, P. O. [1 ]
Emardson, R. [1 ]
Jarlemark, P. [1 ]
Rieck, C. [1 ]
Nilsson, M. [1 ]
Johansson, J. [1 ]
Pendrill, L. [1 ]
Lothberg, P. [1 ]
Nilsson, H. [1 ]
机构
[1] SP Tech Res Inst Sweden, MTk, Boras, Sweden
来源
PROCEEDINGS OF THE 2007 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM-JOINTLY WITH THE 21ST EUROPEAN FREQUENCY AND TIME FORUM, VOLS 1-4 | 2007年
关键词
D O I
10.1109/FREQ.2007.4319090
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have performed a time transfer experiment between two atomic clocks, over a distance of approximately 75 km using an 10 Gbit/s asynchronous fiber-optic computer network. The time transfer was accomplished through passive listening on existing data traffic and a pilot sequence in the SDH bit stream. In order to assess the fiber-link clock comparison, we simultaneously compared the clocks using a GPS carrier phase link. The standard deviation of the difference between the two time transfer links over the three-week time period was 243 ps.
引用
收藏
页码:323 / 326
页数:4