High-throughput multiplex SNP genotyping with MALDI-TOF mass spectrometry: Practice, problems and promise

被引:127
|
作者
Bray, MS
Boerwinkle, E
Doris, PA
机构
[1] Univ Texas, Hlth Sci Ctr, Ctr Human Genet, Houston, TX 77225 USA
[2] Univ Texas, Hlth Sci Ctr, Inst Mol Med, Houston, TX USA
关键词
SNP; genotyping; MALDI-TOF; mass spectrometry; polymorphism; multiplex; ADD1; ADRB2; AGT; AGTR1; GNB3; LPL;
D O I
10.1002/humu.27
中图分类号
Q3 [遗传学];
学科分类号
071007 ; 090102 ;
摘要
Single nucleotide polymorphisms (SNPs) are currently being identified and mapped at a remarkable pace, providing a rich genetic resource with vast potential for disease gene discovery, pharmacogenetics, and understanding the origins of modern humans. High-throughput, cost effective genotyping methods are essential in order to make the most advantageous and immediate use of these SNP data. We have incorporated the use of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF) in our laboratory as a tool for differentiating genotypes based on the mass of the variant DNA sequence, and have utilized this method for production scale SNP genotyping. We have combined a 4 mul PCR amplification reaction using 3 ng of genomic DNA with a secondary enzymatic reaction (mini-sequencing) containing oligonucleotide primers that anneal immediately upstream of the polymorphic site, dideoxynucleotides, and a thermostable polymerase used to extend the PCR product by a single base pair. Mass spectrometry (MS) analysis of mini sequencing reactions was performed using a MALDI-TOF instrument (Voyager-DF, Perseptive Biosystems, Framingham, MA). We performed both single and multiplex PCR and mini sequencing reactions, and genotyped seven different variant sites in a random sample of 989 individuals. Genotypes generated with MS methods were compared with genotypes produced using a 5' exonuclease fluorescence-based assay (Taqman, Applied Biosystems, Foster City CA) and a gel-based genotyping protocol. Because multiple polymorphisms can be detected in a single reaction, the MS technique provides a cost-effective and efficient method for high throughput genotyping, Hum Mutat 17:296-304, 2001, (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:296 / 304
页数:9
相关论文
共 50 条
  • [31] Comparison of high-throughput serum peptide capture methods for peptide profiling by MALDI-TOF mass spectrometry
    Jimenez, C.
    El Filali, Z.
    Marchiori, E.
    Li, K. W.
    Hoekman, K.
    Giaccone, G.
    MOLECULAR & CELLULAR PROTEOMICS, 2006, 5 (10) : S233 - S233
  • [32] An identification of MARK inhibitors using high throughput MALDI-TOF mass spectrometry
    Hruba, Lenka
    Polishchuk, Pavel
    Das, Viswanath
    Hajduch, Marian
    Dzubak, Petr
    BIOMEDICINE & PHARMACOTHERAPY, 2022, 146
  • [33] Detection of genetic variation by MALDI-TOF mass spectrometry: rapid SNP genotyping using the GENOLINK system
    Niemeyer, D
    Elssner, T
    Fahr, K
    Peters, D
    Wenzel, T
    Petkovski, E
    Kostrzewa, M
    PROGRESS IN FORENSIC GENETICS 10, 2004, 1261 : 9 - 11
  • [34] MALDI-TOF mass spectrometry
    Butler, JM
    PROGRESS IN FORENSIC GENETICS 8, 2000, (1193): : 15 - 18
  • [35] Novel Plexor™ SNP genotyping technology:: Comparisons with TaqMan® and homogenous MassEXTEND™ MALDI-TOF mass Spectrometry
    Tindall, E. A.
    Speight, G.
    Petersen, D. C.
    Padilla, E. J. D.
    Hayes, V. M.
    HUMAN MUTATION, 2007, 28 (09) : 922 - 927
  • [36] Multiplexed genotyping of beta globin mutations with MALDI-TOF mass spectrometry
    Looi, Mee-Lee
    Sivalingam, Mageswary
    Husin, Nor Diana
    Radin, Fara Zela Mohd
    Isa, Raihana Mohamed
    Zakaria, Syed Zulkifli Syed
    Hussin, Noor Hamidah
    Alias, Hamidah
    Latiff, Zarina Abd
    Ibrahim, Hishamshah
    Jamal, Rahman
    CLINICA CHIMICA ACTA, 2011, 412 (11-12) : 999 - 1002
  • [37] High-throughput MALDI-TOF mass spectrometry of synthetic polymers: Combinatorial sample preparation with automated data analysis
    Blair, WR
    Wallace, WE
    Byrd, HCM
    Quintavalle, JS
    Guttman, CM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 230 : U3645 - U3645
  • [38] Fast and High-Throughput Evaluation of Photodynamic Effect by Monitoring Specific Protein Oxidation with MALDI-TOF Mass Spectrometry
    Zhou, Shiwei
    Feng, Guangxue
    Wang, Shaowei
    Qi, Guobin
    Wu, Min
    Liu, Bin
    ANALYTICAL CHEMISTRY, 2020, 92 (18) : 12176 - 12184
  • [39] MALDI-TOF Mass Spectrometry-Based High-Throughput Screening for Inhibitors of the Cytosolic DNA Sensor cGAS
    Simon, Roman P.
    Winter, Martin
    Kleiner, Carola
    Ries, Robert
    Schnapp, Gisela
    Heimann, Annekatrin
    Li, Jun
    Zuvela-Jelaska, Ljiljana
    Bretschneider, Tom
    Luippold, Andreas H.
    Reindl, Wolfgang
    Bischoff, Daniel
    Buettner, Frank H.
    SLAS DISCOVERY, 2020, 25 (04) : 372 - 383
  • [40] High performance MALDI-TOF mass spectrometry for proteomics
    Vestal, Marvin
    Hayden, Kevin
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2007, 268 (2-3) : 83 - 92