THEORETICAL STUDY OF HEAT PUMP SYSTEM USING R744/R1234YF AS REFRIGERANT

被引:0
|
作者
Ju, Fujun [1 ]
Fan, Xiaowei [2 ]
Chen, Yaping [1 ]
机构
[1] Southeast Univ, Sch Energy & Environm, Nanjing, Jiangsu, Peoples R China
[2] Zhongyuan Univ Technol, Sch Energy & Environm, Zhengzhou, Peoples R China
来源
PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2015, VOL 8B | 2016年
关键词
heat pump; zeotropic mixtures; R744; R1234yf; exergy efficiency; PERFORMANCE; WORKING;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
In this paper, the eco-friendly zeotropic mixture, R744/R1234yf was chosen as the alternative refrigerant in the instant heat pump water heater system. The cycle performance of heat pump was analyzed theoretically under the nominal working condition of heat pump system. The prediction results show that the new mixture has significant advantages for the instant heat pump with a large heat-sink temperature lift, and there exists an optimal mass fraction of R744/R1234yf, at which the maximum COPh should be obtained. The optimal mass fraction of R744/R1234yf is 17/83 and the system COPh should be attained to 4.29.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Comparative assessment on irreversible losses in heat pumps using R744/R32/R1234yf and R744/R32/R1234ze(E)
    Fukuda, Sho
    Kojima, Hideki
    Kondou, Chieko
    Takata, Nobuo
    Koyama, Shigeru
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2016, 22 (08) : 1118 - 1127
  • [2] R1234yf and R744 as alternatives to R134a at mobile air conditioners
    Onan C.
    Erdem S.
    Journal of Energy Systems, 2021, 5 (04): : 284 - 295
  • [3] Investigation of using R134a, R1234yf and R513A as refrigerant in a heat pump
    A. Yıldız
    R. Yıldırım
    International Journal of Environmental Science and Technology, 2021, 18 : 1201 - 1210
  • [4] Investigation of using R134a, R1234yf and R513A as refrigerant in a heat pump
    Yildiz, A.
    Yildirim, R.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2021, 18 (05) : 1201 - 1210
  • [5] Internal Heat Exchanger System Integration for R1234yf Refrigerant
    Seybold, Lothar
    Hill, William
    Robin, Jean-Jacques
    SAE INTERNATIONAL JOURNAL OF MATERIALS AND MANUFACTURING, 2011, 4 (01) : 181 - 194
  • [6] Comparative investigation and multi objective design optimization of R744/R717, R744/R134a and R744/R1234yf cascade rerfigeration systems
    Turgut, Mert Sinan
    Turgut, Oguz Emrah
    HEAT AND MASS TRANSFER, 2019, 55 (02) : 445 - 465
  • [7] Comparative investigation and multi objective design optimization of R744/R717, R744/R134a and R744/R1234yf cascade rerfigeration systems
    Mert Sinan Turgut
    Oguz Emrah Turgut
    Heat and Mass Transfer, 2019, 55 : 445 - 465
  • [8] PERFORMANCE SIMULATION OF A HEAT PUMP DRYING SYSTEM USING R744 AS REFRIGERANT
    Bantle, Michael
    Kvalsvik, Karoline H.
    Tolstorebrov, Ignat
    12TH IIR GUSTAV LORENTZEN NATURAL WORKING FLUIDS CONFERENCE, 2016, : 244 - 251
  • [9] Critical evaluation of R134a, R1234yf and R744 in passenger car cooling systems
    Grygierzec, Jan
    Werle, Sebastian
    JOURNAL OF POWER TECHNOLOGIES, 2020, 100 (03): : 232 - 239
  • [10] Theoretical analysis and experimental research on R1234yf as alternative to R134a in a heat pump system
    Wang, Hongli
    Zhang, Shuaihua
    Li, Huasong
    Guo, Xiaoying
    ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2023, 42 (03)