A Dynamic, Distributed Model of Shell-and-Tube Heat Exchangers Undergoing Crude Oil Fouling

被引:71
作者
Coletti, Francesco [1 ]
Macchietto, Sandro [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Chem Engn & Chem Technol, London SW7 2AZ, England
基金
英国工程与自然科学研究理事会;
关键词
ENERGY EFFICIENCY; SIMULATION; TEMPERATURE; MITIGATION; DESIGN; IMPACT;
D O I
10.1021/ie901991g
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Fouling in refinery preheat trains causes major energy inefficiencies, resulting in increased costs, greenhouse gas emissions, maintenance efforts, and safety hazards. Fouling deposition is not well understood, and current exchanger design and monitoring practices neglect the local effects and dynamics of fouling, in favor of lumped, steady-state, heuristic models (e.g., Tubular Exchanger Manufacturers Association (TEMA) fouling factors). In this paper, a dynamic, distributed model for a multipass shell-and-tube heat exchanger undergoing crude oil fouling is proposed. The model calculates fouling rates as a function of local conditions and time. It accounts for heat exchanger geometry, variation of oil physical properties with temperature, local accumulation of fouling deposits, and their structural change over time (aging). The interaction between fouling growth and fluid dynamics inside the tubes is accounted for by solving a moving boundary problem. Moreover, a procedure to analyze refinery data and support the estimation of a set of model parameters has been established. The model is validated using data from an ExxonMobil refinery and shows excellent agreement (less than 2% error) with primary plant measurements even when it is tested for its predictive capabilities over long periods (i.e., I year). It is concluded that the model can be used with confidence to identify and predict the fouling state of exchangers, to assess economic losses due to fouling, to support operating decisions such as planning of cleaning schedules, and to assist in the design and retrofit of heat exchangers.
引用
收藏
页码:4515 / 4533
页数:19
相关论文
共 81 条
  • [41] On a new MILP model for the planning of heat-exchanger network cleaning
    Lavaja, JH
    Bagajewicz, MJ
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2004, 43 (14) : 3924 - 3938
  • [42] Integrated design of a conventional crude oil distillation tower using pinch analysis
    Liebmann, K
    Dhole, VR
    Jobson, M
    [J]. CHEMICAL ENGINEERING RESEARCH & DESIGN, 1998, 76 (A3) : 335 - 347
  • [43] INTEGRATED CRUDE DISTILLATION DESIGN
    LIEBMANN, K
    DHOLE, VR
    [J]. COMPUTERS & CHEMICAL ENGINEERING, 1995, 19 : S119 - S124
  • [44] Real time fouling diagnosis and heat exchanger performance
    Liporace, F. S.
    De Oliveira, Sergio Gregorio
    [J]. HEAT TRANSFER ENGINEERING, 2007, 28 (03) : 193 - 201
  • [45] Fouling in Crude Oil Preheat Trains: A Systematic Solution to an Old Problem
    Macchietto, S.
    Hewitt, G. F.
    Coletti, F.
    Crittenden, B. D.
    Dugwell, D. R.
    Galindo, A.
    Jackson, G.
    Kandiyoti, R.
    Kazarian, S. G.
    Luckham, P. F.
    Matar, O. K.
    Millan-Agorio, M.
    Mueller, E. A.
    Paterson, W.
    Pugh, S. J.
    Richardson, S. M.
    Wilson, D. I.
    [J]. HEAT TRANSFER ENGINEERING, 2011, 32 (3-4) : 197 - 215
  • [46] Heat Exchanger Fouling: Environmental Impacts
    Muller-Steinhagen, H.
    Malayeri, M. R.
    Watkinson, A. P.
    [J]. HEAT TRANSFER ENGINEERING, 2009, 30 (10-11) : 773 - 776
  • [47] Modeling of crude oil fouling in preheat exchangers of refinery distillation units
    Nasr, Mohammad Reza Jafari
    Givi, Mehdi Majidi
    [J]. APPLIED THERMAL ENGINEERING, 2006, 26 (14-15) : 1572 - 1577
  • [48] Panchal CB, 2000, HEAT TRANSFER ENG, V21, P1
  • [49] Panchal CB, 1999, UNDERSTANDING HEAT EXCHANGER FOULING AND ITS MITIGATION, P273
  • [50] Panchal CB, 2000, HEAT TRANSFER ENG, V21, P3