Thiocyanate ion selective electrode based on bis(N-3-methylphenyl salicylidenaminato)copper(II) ionophore

被引:20
作者
Benvidi, A. [1 ]
Ghanbarzadeh, M. T. [1 ]
Dehghan, M. [1 ]
Mazloum-Ardakani, M. [1 ]
Vafazadeh, R. [1 ]
机构
[1] Yazd Univ, Fac Sci, Dept Chem, Yazd 89195741, Iran
关键词
Thiocyanate; PVC membrane electrode; Potentiometric determination; Ionophore; MEMBRANE ELECTRODES; SCHIFF-BASE; COMPLEX; METALLOPORPHYRINS; CARRIER;
D O I
10.1016/j.cclet.2014.06.020
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this work a PVC membrane electrode based on bis(N-3-methyl phenyl salicylidenaminato)copper(II) as ionophore was prepared. The electrode was tested by inorganic anions and showed good selectivity for thiocyanate ion. This sensor showed Nerstian behavior with a slope of a -59.3 mV per decade at 25 degrees C. The proposed electrode exhibited a wide linear range from 1.0 x 10(-6) mol/L to 1.0 x 10(-1) mol/L with a detection limit of 5.0 x 10(-7) mol/L. The electrode response was independent of pH in the range of 4.0-10.0. The response time is about 9-21 s, and the electrode can be used for over 60 days without considerable deterioration. The prepared sensor was applied as an indicator electrode in potentiometric titration of SCN- with Ag+ ion and to determine the thiocyanate in samples of urine and saliva. (C) 2014 Published by Elsevier B.V. on behalf of Chinese Chemical Society.
引用
收藏
页码:1639 / 1642
页数:4
相关论文
共 25 条
  • [1] Thiocyanate-selective electrode based on unsymmetrical benzoN4 nickel(II) macrocyclic complexes
    Abbaspour, A
    Kamyabi, MA
    Esmaeilbeig, AR
    Kia, R
    [J]. TALANTA, 2002, 57 (05) : 859 - 867
  • [2] Effects of peripheral and nonperipheral substitution to the spectroscopic, electrochemical and spectroelectrochemical properties of metallophthalocyanines
    Arican, Duygu
    Arici, Mursel
    Ugur, Ahmet Lutfi
    Erdogmus, Ali
    Koca, Atif
    [J]. ELECTROCHIMICA ACTA, 2013, 106 : 541 - 555
  • [3] Novel thiocyanate-selective membrane sensor based on crown ether-cetyltrimethyl ammonium thiocyanate ion-pair as a suitable ionophore
    Arvand, M.
    Zanjanchi, M. A.
    Heydari, L.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2007, 122 (01): : 301 - 308
  • [4] Badri A, 2011, INT J ELECTROCHEM SC, V6, P3178
  • [5] Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics
    Bakker, E
    Buhlmann, P
    Pretsch, E
    [J]. CHEMICAL REVIEWS, 1997, 97 (08) : 3083 - 3132
  • [6] PROBLEMS WITH THIOCYANATE AS AN INDEX OF SMOKING STATUS - A CRITICAL-REVIEW WITH SUGGESTIONS FOR IMPROVING THE USEFULNESS OF BIOCHEMICAL MEASURES IN SMOKING CESSATION RESEARCH
    BLISS, RE
    OCONNELL, KA
    [J]. HEALTH PSYCHOLOGY, 1984, 3 (06) : 563 - 581
  • [7] Ion-selective electrodes for thiocyanate based on the dinuclear Zinc(II) complex of a Bis-N,O-bidentate Schiff base
    Bühlmann, P
    Yahya, L
    Enderes, R
    [J]. ELECTROANALYSIS, 2004, 16 (12) : 973 - 978
  • [8] Highly selective thiocyanate poly(vinyl chloride) membrane electrode based on a cadmium-Schiff's base complex
    Ganjali, MR
    Poursaberi, T
    Basiripour, F
    Salavati-Niasari, M
    Yousefi, M
    Shamsipur, M
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 370 (08): : 1091 - 1095
  • [9] Han W.S., 2011, J AM ANAL CHEM, V2, P731
  • [10] Thiocyanate-selective PVC membrane electrodes based on Mn(II) complex of N,N′-bis-(4-phenylazosalicylidene) o-phenylene diamine as a neutral carrier
    Li, ZQ
    Wu, ZY
    Yuan, R
    Ying, M
    Shen, GL
    Yu, RQ