Automatic lumen segmentation from intravascular OCT images

被引:1
作者
Bourezak, Rafik [1 ,2 ]
Lamouche, Guy [2 ]
Cheriet, Farida [1 ]
机构
[1] Ecole Polytech Montreal, Dept Comp Engn, Campus Univ Montreal,2500 Chemin Polytech, Montreal, PQ H3T 1J4, Canada
[2] Natl Res Council Canada, Inst Ind Mat, Boucherville, PQ J4B 6Y4, Canada
来源
MEDICAL IMAGING 2010: COMPUTER - AIDED DIAGNOSIS | 2010年 / 7624卷
关键词
OCT; lumen segmentation; intravascular imaging; image binarization; contour extraction;
D O I
10.1117/12.844316
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In the last decade intravascular optical coherence tomography has known a tremendous progress. Its high resolution (5-10 mu m) allows coronary plaque characterization, vulnerable plaque assessment, and the guidance of intravascular interventions. However, one intravascular OCT sequence contains hundreds of frames, and their interpretation requires a lot of time and energy. Therefore, there is a strong need for automated segmentation algorithms to process this large amount of data. In this article, we present an automated algorithm to extract lumen contours from images obtained with intravascular Optical Coherence Tomography (OCT). Unlike existing methods, our algorithm requires no post-or preprocessing of the image. First, a sliding window is passed on every A-scan to locate the artery tissue, this location being determined from the largest distribution of the grey level values. Once all the tissue is extracted from the image, every segmented A-scan is binarized separately. For a single A-scan, the level of amplitude often varies strongly across the tissue. A global threshold would cause low amplitude parts of the tissue to be considered as belonging to the background. Our solution is to determine local thresholds for every A-scan. That is, instead of having a single global threshold, we allow the threshold itself to smoothly vary across the image. Subsequently, on the binarized image the Prewitt mask is moved from the detected tissue position toward the probe to segment the lumen. The proposed method has been validated qualitatively on images acquired under different conditions without changing any parameter of the algorithm. Experimental results show that the proposed method is accurate and robust to extract lumen borders.
引用
收藏
页数:5
相关论文
共 5 条
[1]  
BOUREZAK R, 2009, INT C IM AN REC
[2]  
Gebel E., 2008, Heart Disease a Leading Cause of Death Worldwide: Global research projects seek to end preventable heart attacks, strokes
[3]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[4]   Computer recognition of cancer in the urinary bladder using optical coherence tomography and texture analysis [J].
Lingley-Papadopoulos, Colleen A. ;
Loew, Murray H. ;
Manyak, Michael J. ;
Zara, Jason M. .
JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (02)
[5]  
Regar Evelyn., 2007, Optical coherence tomography in cardiovascular research