A unified anti-windup strategy for SISO discrete dead-time compensators

被引:16
作者
Flesch, Rodolfo C. C. [1 ]
Normey-Rico, Julio E. [1 ]
Flesch, Carlos A. [2 ]
机构
[1] Univ Fed Santa Catarina, Dept Automacao & Sistemas, BR-88040900 Florianopolis, SC, Brazil
[2] Univ Fed Santa Catarina, Dept Engenharia Mecan, Cx Post 5053, BR-88040970 Florianopolis, SC, Brazil
关键词
Process control; Delay compensation; Anti windup; Filtered Smith Predictor; Lur'e system; Refrigerant compressor; GENERALIZED PREDICTIVE CONTROL; MODIFIED SMITH PREDICTOR; ACTUATOR SATURATION; DESIGN; SYSTEMS; DELAY; STABILITY; ALGORITHM;
D O I
10.1016/j.conengprac.2017.09.002
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents the development of a unified anti-windup strategy for dead-time compensators that copes with stable, integrating, and unstable single-input and single-output linear plants subject to sector-bounded and memoryless input constraints (such as magnitude or rate saturation, the most common cases in practical applications). A discrete-time Filtered Smith Predictor is used as the base control structure and in this specific case it is shown that stability conditions are related to the primary controller and fast model of the plant instead of the whole control structure. As the design is driven directly in the z-domain, implementation of the strategy using a digital controller is immediate. in addition, simulations and a practical experiment using a vapor-compression refrigeration system with time delay are provided and the results show that the strategy has good performance, close to the one presented by optimal model predictive control structures, with the great advantage of requiring no optimization problem to be numerically solved. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:50 / 60
页数:11
相关论文
共 38 条
[11]   Antiwindup design with guaranteed regions of stability: An LMI-based approach [J].
da Silva, JMG ;
Tarbouriech, S .
IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 2005, 50 (01) :106-111
[12]  
FERTIK HA, 1967, ISA T, V6, P317
[13]   Unified approach for minimal output dead time compensation in MIMO processes [J].
Flesch, Rodolfo C. C. ;
Torrico, Bismark C. ;
Normey-Rico, Julio E. ;
Cavalcante, Marcus U. .
JOURNAL OF PROCESS CONTROL, 2011, 21 (07) :1080-1091
[14]   Modelling, identification and control of a calorimeter used for performance evaluation of refrigerant compressors [J].
Flesch, Rodolfo C. C. ;
Normey-Rico, Julio E. .
CONTROL ENGINEERING PRACTICE, 2010, 18 (03) :254-261
[15]   Reference and command governors for systems with constraints: A survey on theory and applications [J].
Garone, Emanuele ;
Di Cairano, Stefano ;
Kolmanovsky, Ilya .
AUTOMATICA, 2017, 75 :306-328
[16]   Second-order counterexamples to the discrete-time Kalman conjecture [J].
Heath, William Paul ;
Carrasco, Joaquin ;
de la Sen, Manuel .
AUTOMATICA, 2015, 60 :140-144
[17]  
Kapasouris P., 1988, Proceedings of the 27th IEEE Conference on Decision and Control (IEEE Cat. No.88CH2531-2), P469, DOI 10.1109/CDC.1988.194356
[18]   A UNIFIED FRAMEWORK FOR THE STUDY OF ANTIWINDUP DESIGNS [J].
KOTHARE, MV ;
CAMPO, PJ ;
MORARI, M ;
NETT, CN .
AUTOMATICA, 1994, 30 (12) :1869-1883
[19]  
Lozier J., 1956, IRE Transactions on Automatic Control, V1, P19, DOI DOI 10.1109/TAC.1956.1100815
[20]  
Morari M., 1989, ROBUST PROCESS CONTR