Design and fabrication of pulmonary embolism phantom for planar and SPECT V/Q imaging quality assurance

被引:0
作者
Kabir, Norlaili A. [1 ]
Harvey, Steven B. [1 ,2 ]
Rosenfeld, Anatoly [1 ]
机构
[1] Univ Wollongong, Fac Engn, Ctr Med Radiat Phys, Wollongong, NSW 2522, Australia
[2] Wollongong Hosp, Dept Nucl Med, Wollongong, NSW, Australia
关键词
Quality assurance; Phantom; Pulmonary embolism; Ventilation/perfusion (V/Q); Lung perfusion defect; CT;
D O I
10.1007/s13246-010-0025-5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Planar and Single Photon Emission Computed Tomography (SPECT) scintigraphy are the two main modalities for pulmonary embolism (PE) diagnosis via lung ventilation/perfusion (V/Q) scans. This study aims to develop an anatomical lung phantom for the quality assurance (QA) of V/Q scans using planar and SPECT imaging. The phantom consists of two hollow anatomical lung cavities and 20 solid anatomical bronchopulmonary segments. The phantom functions as a PE simulator by enabling an interchangeable perfusion defect, represented by a solid anatomical bronchopulmonary segment, to be introduced into each of the lung cavities. These cavities are filled with expanded polystyrene (EPS) beads immersed in a (99m)Tc solution, which simulates the alveoli. The anatomical 'dead space' due to the solid introduced segment represents a perfusion defect in lung V/Q scans. In this study, a sample anatomical PE event was simulated. The phantom was prepared with a perfusion defect within the posterior basal segment in the left lung. Images were acquired for subsequent qualitative analysis. This study has demonstrated promising results in the simulation of PE events in lungs. Further development is warranted for the phantom to be used as a viable QA tool in V/Q lung scanning using planar or SPECT imaging.
引用
收藏
页码:271 / 277
页数:7
相关论文
共 12 条
[1]   Computed tomographic pulmonary angiography vs ventilation-perfusion lung scanning in patients with suspected pulmonary embolism - A Randomized controlled trial [J].
Anderson, David R. ;
Kahn, Susan R. ;
Rodger, Marc A. ;
Kovacs, Michael J. ;
Morris, Tim ;
Hirsch, Andrew ;
Lang, Eddy ;
Stiell, Ian ;
Kovacs, George ;
Dreyer, Jon ;
Dennie, Carol ;
Cartier, Yannick ;
Barnes, David ;
Burton, Erica ;
Pleasance, Susan ;
Skedgel, Chris ;
O'Rouke, Keith ;
Wells, Philip S. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 298 (23) :2743-2753
[2]  
BOYES J, 2003, QUEENS HLTH SCI J, V6, P23
[3]  
CLEMENTE CD, 2007, ANATOMY REGIONAL ATL, P119
[4]  
CRINER GJ, 1999, PULMONARY PATHOPHYSI, P26
[5]  
Heikkinen JO, 2006, J NUCL MED TECHNOL, V34, P34
[6]  
OSER RF, 1996, RADIOLOGY, V199, P1
[7]  
Palmer J, 2001, J NUCL MED, V42, P1288
[8]   Effect of motion on tracer activity determination in CT attenuation corrected PET images: A lung phantom study [J].
Pevsner, A ;
Nehmeh, SA ;
Humm, JL ;
Mageras, GS ;
Erdi, YE .
MEDICAL PHYSICS, 2005, 32 (07) :2358-2362
[9]  
Reinartz P, 2004, J NUCL MED, V45, P1501
[10]  
RHOADES RA, 2003, MED PHYSL, P310