摘要
Despite being an excellent tool for investigating ultrastructure, scanning electron microscopy (SEM) is less frequently used than transmission electron microscopy for microbes such as viruses or bacteria. Here we describe rapid methods that allow SEM imaging of fully hydrated, unfixed microbes without using conventional sample preparation methods. We demonstrate improved ultrastructural preservation, with greatly reduced dehydration and shrinkage, for specimens including bacteria and viruses such as Ebola virus using infiltration with ionic liquid on conducting filter substrates for SEM.
引用
收藏
页数:8
相关论文
共 34 条
[21]   Study of SEM preparation artefacts with correlative microscopy: Cell shrinkage of adherent cells by HMDS-drying [J].
Katsen-Globa, Alisa ;
Puetz, Norbert ;
Gepp, Michael M. ;
Neubauer, Julia C. ;
Zimmermann, Heiko .
SCANNING, 2016, 38 (06) :625-633
[22]   Simple pretreatment of non-conductive small hydrous bio-samples with choline-type ionic liquid and membrane filter for microsample mounting [J].
Kawai, Koji ;
Kaneko, Kotaro ;
Kawakami, Hayato ;
Narushima, Takashi ;
Yonezawa, Tetsu .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2013, 102 :9-12
[23]   The impact of primer and probe-template mismatches on the sensitivity of pandemic influenza A/H1N1/2009 virus detection by real-time RT-PCR [J].
Klungthong, Chonticha ;
Chinnawirotpisan, Piyawan ;
Hussem, Kittinun ;
Phonpakobsin, Thipwipha ;
Manasatienkij, Wudtichai ;
Ajariyakhajorn, Chuanpis ;
Rungrojcharoenkit, Kamonthip ;
Gibbons, Robert V. ;
Jarman, Richard G. .
JOURNAL OF CLINICAL VIROLOGY, 2010, 48 (02) :91-95
[24]   Observation of ionic liquid by scanning electron microscope [J].
Kuwabata, Susumu ;
Kongkanand, Anusorn ;
Oyamatsu, Daisuke ;
Torimoto, Tsukasa .
CHEMISTRY LETTERS, 2006, 35 (06) :600-601
[25]   Leptospirosis [J].
Levett, PN .
CLINICAL MICROBIOLOGY REVIEWS, 2001, 14 (02) :296-+
[26]   Molecular diagnosis of severe acute respiratory syndrome - The state of the art [J].
Mahony, JB ;
Richardson, S .
JOURNAL OF MOLECULAR DIAGNOSTICS, 2005, 7 (05) :551-559
[27]   Pitfalls in diagnosing human poxvirus infections [J].
Nitsche, Andreas ;
Gelderblom, Hans R. ;
Eisendle, Klaus ;
Romani, Nikolaus ;
Pauli, Georg .
JOURNAL OF CLINICAL VIROLOGY, 2007, 38 (02) :165-168
[28]   Nanoscale analysis of unstained biological specimens in water without radiation damage using high-resolution frequency transmission electric-field system based on FE-SEM [J].
Ogura, Toshihiko .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2015, 459 (03) :521-528
[29]   Evaluation of the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 Test and Identification of Rare Polymorphisms Potentially Affecting Assay Performance [J].
Pyne, Michael T. ;
Brown, Katherine L. ;
Hillyard, David R. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (08) :2852-2858
[30]   FE-SEM Observation of Swelled Seaweed Using Hydrophilic Ionic Liquid; 1-butyl-3-methylimidazolium tetrafluoroborate [J].
Takahashi, Chisato ;
Shirai, Takashi ;
Fuji, Masayoshi .
MICROSCOPY RESEARCH AND TECHNIQUE, 2013, 76 (01) :66-71