In-vivo evaluation of flow characteristics of novel metal ureteral stent

被引:37
作者
Blaschko, Sarah D. [1 ]
Deane, Leslie Allan [1 ]
Krebs, Alfred [1 ]
Abdelshehid, Corollos S. [1 ]
Khan, Farhan [1 ]
Borin, James [1 ]
Nguyen, Alex [1 ]
McDougall, Elspeth M. [1 ]
Clayman, Ralph V. [1 ]
机构
[1] Univ Calif Irvine, Med Ctr, Dept Urol, Orange, CA 92868 USA
关键词
D O I
10.1089/end.2006.0315
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To characterize the flow of a novel ureteral stent composed of a nickel-cobalt-chromium-molybdenum alloy and compare it with flow in a standard ureteral stent. Materials and Methods: Six 6F Resonance stents and six 6F standard Black Beauty ureteral stents were placed in six Yucatan minipigs, with each pig serving as its own control. Flow assessment was performed on all stents via a nephrostomy tube delivering a standard rate of 0.9% saline at 35 cm H2O. Flow studies on the standard stents encompassed extraluminal ( i.e., lumen of stent occluded with a guidewire), intraluminal ( i.e., ureter secured to stent with a constricting suture), and combined ( i.e., open lumen without constricting suture) flow. In the Resonance stent, only combined and intraluminal flow could be addressed, as there is no access to the lumen of this stent. Results: With the Resonance stent, intraluminal flow was much greater than combined flow, with mean values of 5.15 mL/min and 2.50 mL/min, respectively ( P = 0.057; SD = 7.73). Intraluminal flow was similar to combined flow in the 6F standard stent, with mean values of 7.34 mL/min and 7.30 mL/min, respectively ( P = 0.88; SD = 1.76). The standard stent had significantly greater combined flow than the Resonance stent ( P = 0.023) but not intraluminal flow ( P = 0.247). Of note, whereas it was possible to occlude the 6F standard stent completely with a ureteral ligature ( i. e., no guidewire placed in the lumen), it was not possible to occlude the Resonance stent regardless of how tightly the suture was tied. Conclusion: The Resonance metal alloy stent provides less overall flow than a standard stent. However, under circumstances of extrinsic ureteral compression sufficient to occlude a standard stent ( e. g., extrinsic compression plus an internal guidewire), the metal stent continues to provide satisfactory drainage.
引用
收藏
页码:780 / 783
页数:4
相关论文
共 8 条
[1]  
BORIN JF, IN PRESS J ENDOUROL
[2]   Mechanism of ureteral stent flow:: A comparative in vivo study [J].
Brewer, AV ;
Elbahnasy, AM ;
Bercowsky, E ;
Maxwell, KL ;
Shalhav, AL ;
Kahn, SA ;
McDougall, EM ;
Clayman, RV .
JOURNAL OF ENDOUROLOGY, 1999, 13 (04) :269-271
[3]  
HAFRON JM, IN PRESS UROLOGY
[4]   THE DOUBLE-J URETERAL STENT - INVIVO AND INVITRO FLOW STUDIES [J].
HUBNER, WA ;
PLAS, EG ;
STOLLER, ML .
JOURNAL OF UROLOGY, 1992, 148 (02) :278-280
[5]   Nickel-titanium shape memory alloy Memokath 051 ureteral stent for managing long-term ureteral obstruction: 4-year experience [J].
Kulkarni, R ;
Bellamy, E .
JOURNAL OF UROLOGY, 2001, 166 (05) :1750-1754
[6]   Ureteral metal stents: A tale or a tool? [J].
Liatsikos, EN ;
Kagadis, GC ;
Barbalias, GA ;
Siablis, D .
JOURNAL OF ENDOUROLOGY, 2005, 19 (08) :934-939
[7]   COMPARATIVE-EVALUATION OF MATERIALS USED FOR INTERNAL URETERAL STENTS [J].
MARDIS, HK ;
KROEGER, RM ;
MORTON, JJ ;
DONOVAN, JM .
JOURNAL OF ENDOUROLOGY, 1993, 7 (02) :105-115
[8]   Can the complicated forgotten indwelling ureteric stents be lethal? [J].
Singh, V. ;
Srinivastava, A. ;
Kapoor, R. ;
Kumar, A. .
INTERNATIONAL UROLOGY AND NEPHROLOGY, 2005, 37 (03) :541-546