摘要
Introduction: The performance of laryngoscopes that have been developed for difficult airways can vary widely. The aim of the study was to compare Macintosh, McCoy, McGrath MAC, and C-MAC laryngoscopes in cervical immobilization and tongue edema scenarios in a mannequin, primarily to evaluate the time to intubation. Methods: In this randomized crossover study, 41 anesthesiology residents used 4 laryngoscopes in a mannequin (SimMan 3G) in 2 different scenarios. Intubation time (insertion of the blade between the teeth, to placement of the endotracheal tube into the trachea) longer than 120 seconds or inability to successfully place the endotracheal tube into the trachea after 5 or more attempts was defined as intubation failure. Besides intubation time, laryngoscopic view, number of intubation attempts, presence of esophagealintubation, need for stylet, difficulty of intubation, and success rate were recorded as secondary outcomes. Results: Intubation time was observed from longest to shortest as McGrath > McCoy > C-MAC > Macintosh in both scenarios. Laryngeal view was better with C-MAC laryngoscope. McGrath laryngoscope performed poorly specifically in tongue edema scenarios, which resulted in higher number of intubation attempts, esophageal intubation, need for intubation stylets, and overall intubation failure. Conclusions: The short intubation time observed with the Macintosh underlines the necessity of familiarity in success:Tongue edema is a more challenging scenario for simulated difficult airway and the McGrath may not be a good choice for such a scenario.
引用
收藏
页码:304 / 308
页数:5
相关论文
共 23 条
[1]  
Campos JH, 2015, MINERVA ANESTESIOL, V81, P1
[2]   DIFFICULT TRACHEAL INTUBATION IN OBSTETRICS [J].
CORMACK, RS ;
LEHANE, J .
ANAESTHESIA, 1984, 39 (11) :1105-1111
[3]   Difficult Airway Society guidelines for management of the unanticipated difficult intubation [J].
Henderson, JJ ;
Popat, MT ;
Latto, IP ;
Pearce, AC .
ANAESTHESIA, 2004, 59 (07) :675-694
[4]   Evaluation of the airway of the SimMan™ full-scale patient simulator [J].
Hesselfeldt, R ;
Kristensen, MS ;
Rasmussen, LS .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2005, 49 (09) :1339-1345
[5]  
Jain D, 2014, REV BRAS ANESTESIOL, V64, P269, DOI [10.1016/j.bjane.2013.06.005, 10.1016/j.bjan.2013.06.006]
[6]   A comparison of direct and indirect laryngoscopes and the ILMA in novice users: a manikin study [J].
Maharaj, C. H. ;
McDonnell, J. G. ;
Harte, B. H. ;
Laffey, J. G. .
ANAESTHESIA, 2007, 62 (11) :1161-1166
[7]   Evaluation of intubation using the Airtraq® or Macintosh laryngoscope by anaesthetists in easy and simulated difficult laryngoscopy -: a manikin study [J].
Maharaj, CH ;
Higgins, BD ;
Harte, BH ;
Laffey, JG .
ANAESTHESIA, 2006, 61 (05) :469-477
[8]   Comparison of the C-MAC® videolaryngoscope with the Macintosh, Glidescope®, and Airtraq® laryngoscopes in easy and difficult laryngoscopy scenarios in manikins [J].
McElwain, J. ;
Malik, M. A. ;
Harte, B. H. ;
Flynn, N. M. ;
Laffey, J. G. .
ANAESTHESIA, 2010, 65 (05) :483-489
[9]   Comparison of Intubation Success of Video Laryngoscopy Versus Direct Laryngoscopy in the Difficult Airway Using High-Fidelity Simulation [J].
Narang, Aneesh T. ;
Oldeg, Paula F. ;
Medzon, Ron ;
Mahmood, Ahmed R. ;
Spector, Jordan A. ;
Robinett, Derek A. .
SIMULATION IN HEALTHCARE, 2009, 4 (03) :160-165
[10]   Randomized controlled trial comparing the McGrath videolaryngoscope with the C-MAC videolaryngoscope in intubating adult patients with potential difficult airways [J].
Ng, I. ;
Hill, A. L. ;
Williams, D. L. ;
Lee, K. ;
Segal, R. .
BRITISH JOURNAL OF ANAESTHESIA, 2012, 109 (03) :439-443