Correction factors for A1SL ionization chamber dosimetry in TomoTherapy: Machine-specific, plan-class, and clinical fields

被引:22
作者
Gago-Arias, Araceli [1 ]
Rodriguez-Romero, Ruth [2 ]
Sanchez-Rubio, Patricia [2 ]
Miguel Gonzalez-Castano, Diego [1 ,3 ]
Gomez, Faustino [1 ,3 ]
Nunez, Luis [2 ]
Palmans, Hugo [4 ]
Sharpe, Peter [4 ]
Pardo-Montero, Juan [1 ]
机构
[1] Univ Santiago de Compostela, Fac Fis, Dept Fis Particulas, Santiago De Compostela 15782, Spain
[2] Hosp Univ Puerta Hierro, Serv Radiofis, Madrid 28222, Spain
[3] Univ Santiago de Compostela, Radiat Phys Lab, Santiago De Compostela 15782, Spain
[4] Natl Phys Lab, Teddington TW11 0LW, Middx, England
关键词
nonstandard fields; TomoTherapy; reference dosimetry; correction factor; HELICAL TOMOTHERAPY; CALIBRATION; PHOTON; BEAMS;
D O I
10.1118/1.3692181
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Recently, an international working group on nonstandard fields presented a new formalism for ionization chamber reference dosimetry of small and nonstandard fields [Alfonso et al., Med. Phys. 35, 5179-5186 (2008)] which has been adopted by AAPM TG-148. This work presents an experimental determination of the correction factors for reference dosimetry with an Exradin A1SL thimble ionization chamber in a TomoTherapy unit, focusing on: (i) machine-specific reference field, (ii) plan-class-specific reference field, and (iii) two clinical treatments. Methods: Ionization chamber measurements were performed in the TomoTherapy unit for intermediate (machine-specific and plan-class-specific) calibration fields, based on the reference conditions defined by AAPM TG-148, and two clinical treatments (lung and head-and-neck). Alanine reference dosimetry was employed to determine absorbed dose to water at the point of interest for the fields under investigation. The corresponding chamber correction factors were calculated from alanine to ionization chamber measurements ratios. Results: Two different methods of determining the beam quality correction factor k(Q,Q0) for the A1SL ionization chamber in this TomoTherapy unit, where reference conditions for conventional beam quality determination cannot be met, result in consistent values. The observed values of overall correction factors obtained for intermediate and clinical fields are consistently around 0.98 with a typical expanded relative uncertainty of 2% (k = 2), which when considered make such correction factors compatible with unity. However, all of them are systematically lower than unity, which is shown to be significant when a hypothesis test assuming a t-student distribution is performed (p = 1.8 x 10(-2)). Correction factors k(Qclin,Qpcsr)(fclin,fpcsr); k(Qclin,Qmsr)(fclin,mcsr) which are needed for the computation of field factors for relative dosimetry of clinical beams, have been found to be very close to unity for two clinical treatments. Conclusions: The results indicate that the helical field deliveries in this study (including two clinical fields) do not introduce changes on the ion chamber correction factors for dosimetry. For those two specific clinical cases, ratios of chamber readings accurately represent field output factors. The values observed here for intermediate calibration fields are in agreement with previously published data based on alanine dosimetry but differ from values recently reported obtained via radiochromic dosimetry. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.3692181]
引用
收藏
页码:1964 / 1970
页数:7
相关论文
共 21 条
[1]   A new formalism for reference dosimetry of small and nonstandard fields [J].
Alfonso, R. ;
Andreo, P. ;
Capote, R. ;
Huq, M. Saiful ;
Kilby, W. ;
Kjaell, P. ;
Mackie, T. R. ;
Palmans, H. ;
Rosser, K. ;
Seuntjens, J. ;
Ullrich, W. ;
Vatnitsky, S. .
MEDICAL PHYSICS, 2008, 35 (11) :5179-5186
[2]   AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams [J].
Almond, PR ;
Biggs, PJ ;
Coursey, BM ;
Hanson, WF ;
Huq, MS ;
Nath, R ;
Rogers, DWO .
MEDICAL PHYSICS, 1999, 26 (09) :1847-1870
[3]  
Andreo P., 2001, TRS398 IAEA
[4]  
[Anonymous], 1995, GUID EXPR UNC MEAS
[5]   An absolute dose determination of helical tomotherapy accelerator, TomoTherapy High-Art II [J].
Bailat, Claude J. ;
Buchillier, Thierry ;
Pachoud, Marc ;
Moeckli, Raphael ;
Bochud, Francois O. .
MEDICAL PHYSICS, 2009, 36 (09) :3891-3896
[6]   On charged particle equilibrium violation in external photon fields [J].
Bouchard, Hugo ;
Seuntjens, Jan ;
Palmans, Hugo .
MEDICAL PHYSICS, 2012, 39 (03) :1473-1480
[7]   Ionization chamber gradient effects in nonstandard beam configurations [J].
Bouchard, Hugo ;
Seuntjens, Jan ;
Carrier, Jean-Francois ;
Kawrakow, Iwan .
MEDICAL PHYSICS, 2009, 36 (10) :4654-4663
[8]   Dosimetry audit for tomotherapy using alanine/EPR [J].
Duane, S. ;
Nicholas, D. ;
Palmans, H. ;
Schaeken, B. ;
Sephton, J. ;
Sharpe, P. ;
Thomas, R. ;
Tomsej, M. ;
Tournel, K. ;
Verellen, D. ;
Vynckier, S. .
MEDICAL PHYSICS, 2006, 33 (06) :2093-2094
[9]  
International Electrotechnical Commission (IEC), 2008, 61217 IEC
[10]   Dose calibration of nonconventional treatment systems applied to helical tomotherapy [J].
Jeraj, R ;
Mackie, TR ;
Balog, J ;
Olivera, G .
MEDICAL PHYSICS, 2005, 32 (02) :570-577