Trabecular shear stress in human vertebral cancellous bone: intra- and inter-individual variations

被引:27
作者
Yeni, YN
Hou, FJ
Vashishth, D
Fyhrie, DP
机构
[1] Henry Ford Hosp, Ctr Bone & Joint, Breech Res Lab, Detroit, MI 48202 USA
[2] Shell Int Explorat & Prod Inc, Bellaire Technol Ctr, Houston, TX 77025 USA
[3] Rensselaer Polytech Inst, Dept Biomed Engn, Troy, NY 12180 USA
关键词
cancellous bone; vertebra; stress; micro tomography; finite element analysis;
D O I
10.1016/S0021-9290(01)00089-6
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Correlation of the mean and standard deviation of trabecular stresses has been proposed as a mechanism by which a strong relationship between the apparent strength and stiffness of cancellous bone can be achieved. The current study examined whether the relationship between the mean and standard deviation of trabecular von Mises stresses can be generalized for any group of cancellous bone. Cylindrical human vertebral cancellous bone specimens were cut in the infero-superior direction from T12 of 23 individuals (inter-individual group), Thirty nine additional specimens were prepared similarly from the T4-T12 and L2-L5 vertebrae of a 63 year old male (intra-individual group). The specimens were scanned by micro-computed tomography (mu CT) and trabecular von Mises stresses were calculated using finite element modeling. The expected value, standard deviation and coefficient of variation of the von Mises stress were calculated form a three-parameter Weibull function fitted to von Mises stress data from each specimen. It was found that the average and standard deviation of trabecular von Mises shear stress were: (i) correlated with each other, supporting the idea that high correlation between the apparent strength and stiffness of cancellous bone can be achieved through controlling the trabecular level shear stress variations, (ii) dependent on anatomical site and sample group, suggesting that the variation of stresses are correlated to the mean stress to different degrees between vertebrae and individuals, and (iii) dependent on bone volume fraction. consistent with the idea that shear stress is less well controlled in bones with low BV/TV. The conversion of infero-superior loading into trabecular von Mises stresses was maximum for the tissue at the junction of the thoracic and lumbar spine (T12-L1) consistent with this junction being a common site of vertebral fracture. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1341 / 1346
页数:6
相关论文
共 23 条
  • [1] Boresi A.P., 1993, ADV MECH MAT, VFifth
  • [2] Bury K., 1999, STAT DISTRIBUTIONS E
  • [3] Femoral strength is better predicted by finite element models than QCT and DXA
    Cody, DD
    Gross, GJ
    Hou, FJ
    Spencer, HJ
    Goldstein, SA
    Fyhrie, DP
    [J]. JOURNAL OF BIOMECHANICS, 1999, 32 (10) : 1013 - 1020
  • [4] THE DIRECT EXAMINATION OF 3-DIMENSIONAL BONE ARCHITECTURE INVITRO BY COMPUTED-TOMOGRAPHY
    FELDKAMP, LA
    GOLDSTEIN, SA
    PARFITT, AM
    JESION, G
    KLEEREKOPER, M
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 1989, 4 (01) : 3 - 11
  • [5] Bone stiffness predicts strength similarly for human vertebral cancellous bone in compression and for cortical bone in tension
    Fyhrie, DP
    Vashishth, D
    [J]. BONE, 2000, 26 (02) : 169 - 173
  • [6] FAILURE MECHANISMS IN HUMAN VERTEBRAL CANCELLOUS BONE
    FYHRIE, DP
    SCHAFFLER, MB
    [J]. BONE, 1994, 15 (01) : 105 - 109
  • [7] HUMAN VERTEBRAL CANCELLOUS BONE SURFACE DISTRIBUTION
    FYHRIE, DP
    LANG, SM
    HOSHAW, SJ
    SCHAFFLER, MB
    KUO, RF
    [J]. BONE, 1995, 17 (03) : 287 - 291
  • [8] DIRECT CALCULATION OF THE SURFACE-TO-VOLUME RATIO FOR HUMAN CANCELLOUS BONE
    FYHRIE, DP
    FAZZALARI, NL
    GOULET, R
    GOLDSTEIN, SA
    [J]. JOURNAL OF BIOMECHANICS, 1993, 26 (08) : 955 - 967
  • [9] FYHRIE DP, 2000, ANN BIOMED ENG, V28, P1
  • [10] Human vertebral body apparent and hard tissue stiffness
    Hou, FJ
    Lang, SM
    Hoshaw, SJ
    Reimann, DA
    Fyhrie, DP
    [J]. JOURNAL OF BIOMECHANICS, 1998, 31 (11) : 1009 - 1015