RADIATION DOSE MANAGEMENT IN CT, SPECT/CT AND PET/CT TECHNIQUES

被引:51
|
作者
Mattsson, Soren [1 ]
Soderberg, Marcus [1 ]
机构
[1] Lund Univ, Skane Univ Hosp Malmo, Dept Clin Sci Malmo, SE-20502 Lund, Sweden
关键词
ITERATIVE RECONSTRUCTION TECHNIQUE; AUTOMATIC EXPOSURE CONTROL; COMPUTED-TOMOGRAPHY; X-RAY; REDUCTION; VALIDATION; FLUORODEOXYGLUCOSE; TOMOSYNTHESIS; OPTIMIZATION; TECHNICIANS;
D O I
10.1093/rpd/ncr261
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
New imaging technologies utilising X rays and radiopharmaceuticals are continuously under development. The benefit of computed tomography (CT) has been so dramatic that there is a tendency to overuse it and not to place enough efforts into optimisation of the technique. It is also now more and more common to combine two imaging techniques into a single investigation, such as PET/CT and SPECT/CT-the so-called 'hybrid imaging'. The increasing radiation exposure from CT has been of concern for some years and is now receiving increased attention from health professionals, authorities, manufacturers and patient groups. The relatively high radiation doses from PET and SPECT investigations have only recently been discussed. The aim of this article is to provide information on developing technologies and clinical techniques for 3D imaging using ionising radiation and their associated radiation dose to patients and staff. Tools for improved dose management are also discussed.
引用
收藏
页码:13 / 21
页数:9
相关论文
共 50 条
  • [41] Cardiac SPECT-CT and PET-CT Imaging
    Flotats, Albert
    Hasbak, Philip
    Hidalgo, Alberto
    Leta, Ruben
    CURRENT MEDICAL IMAGING, 2011, 7 (03) : 175 - 192
  • [42] Is there still a role for SPECT–CT in oncology in the PET–CT era?
    Rodney J. Hicks
    Michael S. Hofman
    Nature Reviews Clinical Oncology, 2012, 9 : 712 - 720
  • [43] AN EVALUATION OF SUV ACCURACY IN QUANTITATIVE PET/CT AND SPECT/CT
    Willowson, K.
    Bailey, D.
    Baldock, C.
    Isoardi, R.
    INTERNAL MEDICINE JOURNAL, 2011, 41 : 7 - 7
  • [44] SPECT-CT and PET-CT in Oncology - An Overview
    Basu, Sandip
    Alavi, Abass
    CURRENT MEDICAL IMAGING, 2011, 7 (03) : 202 - 209
  • [45] Use of SPECT/CT and PET/CT for epithelial thyroid cancers
    Giraudet, A. -L.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2014, 38 (03): : 179 - 183
  • [46] Primary Pulmonary Osteosarcoma PET/CT and SPECT/CT Findings
    Gu, Taoying
    Shi, Hongcheng
    Xiu, Yan
    Gu, Yushen
    CLINICAL NUCLEAR MEDICINE, 2011, 36 (12) : E209 - E212
  • [47] Comparison of misregistration artifacts on cardiac SPECT/CT and PET/CT
    Kim, Jahae
    Cho, Sang-Geon
    Park, Ki Seong
    Jeong, Geum-Cheol
    Park, Hee Jeong
    Kang, Sae-Ryung
    Kwon, Seong Young
    Min, Jung-Joon
    Song, Ho-Chun
    Bom, Hee-Seung
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [48] Impact of CT radiation in overall patient effective dose, for hybrid SPECT-CT imaging
    Dias, A. H.
    Gaspar, C. J. P.
    Pintao, S.
    Almeida, P.
    Martins, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S420 - S420
  • [49] Radiation dose in cardiac SPECT/CT: An estimation of SSDE and effective dose
    Abdollahi, Hamid
    Shiri, Isaac
    Salimi, Yazdan
    Sarebani, Maghsoud
    Mehdinia, Reza
    Deevband, Mohammad Reza
    Mahdavi, Seied Rabi
    Sohrabi, Ahmad
    Bitarafan-Rajabi, Ahmad
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (12) : 2257 - 2261
  • [50] Diagnostic Reference Levels of CT Radiation Dose in Whole-Body PET/CT
    Jallow, Ngoneh
    Christian, Paul
    Sunderland, John
    Graham, Michael
    Hoffman, John M.
    Nye, Jonathon A.
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (02) : 238 - 241