共 41 条
Development and validation of a chemiluminescent immunodetection assay amenable to high throughput screening of antiviral drugs for Nipah and Hendra virus
被引:29
作者:
Aljofan, Moharnad
[1
]
Porotto, Matteo
[2
]
Moscona, Anne
[2
]
Mungall, Bruce A.
[1
]
机构:
[1] CSIRO Livestock Ind, Australian Anim Hlth Lab, Geelong, Vic 3220, Australia
[2] Cornell Univ, Weill Med Coll, Ithaca, NY 14853 USA
关键词:
paramyxovirus;
Hendra virus;
Nipah virus;
henipavirus;
high throughput screening;
monolayer assay;
immunoassay;
D O I:
10.1016/j.jviromet.2008.01.016
中图分类号:
Q5 [生物化学];
学科分类号:
071010 ;
081704 ;
摘要:
There are currently no antiviral drugs approved for the highly lethal Biosafety Level 4 pathogens Nipah and Hendra virus. A number of researchers are developing surrogate assays amenable to Biosafety Level 2 biocontainment but ultimately, the development of a high throughput screening method for directly quantifying these viruses in a Biosafety Level 4 environment will be critical for final evaluation of antiviral drugs identified in surrogate assays, in addition to reducing the time required for effective antiviral drug development. By adapting an existing immunoplaque assay and using enzyme linked immunodetection in a microtitre plate format, the current experiments describe a simple two step assay protocol involving an overnight virus inoculation of Vero cell monolayers (with or without antiviral drug treatment) at Biosafety Level 4, followed by cell fixation and virus inactivation enabling removal of plates from the Biosafety Level 4 laboratory and a subsequent immunodetection assay using a chemiluminescent horse radish peroxidase substrate to be performed at Biosafety Level 2. The analytical sensitivity (limit of detection) of this assay is 100 tissue culture infectious dose(50)/ml of either Nipah or Hendra virus. In addition this assay enables linear quantitation of virus over three orders of magnitude and is unaffected by dimethyl sulfoxide concentrations of 1% or less. Intra-assay coefficients of variation are acceptable (less than 20%) when detecting a minimum of 1000 tissue culture infectious dose(50)/ml of either virus although inter-assay variation is considerably greater. By an assessment of efficacies of the broad spectrum antiviral Ribavirin and an experimental fusion inhibitory peptide, this assay reveals a good correlation with previously published fluorescent immunodetection assays. The current experiments describe for the first time, a high throughput screening method amenable for direct assessment of live henipavirus antiviral drug activity. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:12 / 19
页数:8
相关论文