Results of intertrochanteric femur fractures treated with a 135-degree sliding screw with a two-hole side plate

被引:51
作者
Bolhofner, BR [1 ]
Russo, PR [1 ]
Carmen, B [1 ]
机构
[1] Bayfront Med Ctr, St Petersburg, FL USA
关键词
fracture; intertrochanteric; side plate; sliding screw;
D O I
10.1097/00005131-199901000-00002
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: To observe and report the clinical results of the treatment of intertrochanteric hip fractures treated with a 135-degree hip screw with a two-hole side plate. Design: Prospective consecutive. Setting: Community private practice. Patients: A consecutive series of seventy primarily older patients with intertrochanteric hip fractures treated in a community hospital setting. Intervention: Surgical treatment with a 135-degree sliding hip screw and a two-hole side plate. Main Outcome Measurements: Healing rate and time, operative blood loss and time, incidence of hardware failure, and complications including loss of side plate fixation and amount of collapse. Results: Sixty-nine patients, with seventy intertrochanteric hip fractures, underwent surgical treatment with a 135-degree sliding hip screw and a two-hole side plate. There were twenty-one (30 percent) A1.1, sixteen (23 percent) A1.2, twenty-one (30 percent) A2.1, and twelve (17 percent) A2.2 fractures in twenty three (33 percent) men and forty-six (67 percent) women. Average age was seventy-nine years. The average estimated blood loss was seventy-seven cubic centimeters (range 10 to 300 cubic centimeters), and the average surgical time was thirty-one minutes (range 8 to 90 minutes). The average time to union was fifteen weeks (range 8 to 17 weeks). There were three failures: two from screw cut-out and one from screw plate dissociation. No cases failed due to loss of fixation of the two-hole side plate. Collapse was minimum in fifty-five patients (79 percent), moderate in twelve patients (17 percent), and severe in two patients (3 percent). Conclusions: Use of the 135-degree sliding hip screw with a two-hole side plate produces satisfactory healing and results in relatively low blood loss and short surgical times without the loss of side plate fixation.
引用
收藏
页码:5 / 8
页数:4
相关论文
共 30 条
[1]  
APEL DM, 1989, CLIN ORTHOP RELAT R, P156
[2]  
Bendo J A, 1994, Orthop Rev, VSuppl, P30
[3]  
CLAWSON D K, 1964, J Trauma, V4, P737, DOI 10.1097/00005373-196411000-00001
[4]   INTERTROCHANTERIC FEMORAL FRACTURES - MECHANICAL FAILURE AFTER INTERNAL-FIXATION [J].
DAVIS, TRC ;
SHER, JL ;
HORSMAN, A ;
SIMPSON, M ;
PORTER, BB ;
CHECKETTS, RG .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (01) :26-31
[5]  
DOHERTY JH, 1979, CLIN ORTHOP RELAT R, P184
[6]  
GALANAKIS IA, 1995, CLIN ORTHOP RELAT R, P206
[7]  
GANZ R, 1979, CLIN ORTHOP RELAT R, P30
[8]   HOW EFFECTIVE ARE OSTEOTOMIES FOR UNSTABLE INTERTROCHANTERIC FRACTURES [J].
GARGAN, MF ;
GUNDLE, R ;
SIMPSON, AHRW .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (05) :789-792
[9]   CLINICAL-EVALUATION OF THE SLIDING COMPRESSION SCREW IN 121 HIP-FRACTURES [J].
GREIDER, JL ;
HOROWITZ, M .
SOUTHERN MEDICAL JOURNAL, 1980, 73 (10) :1343-1348
[10]   HOW TO MINIMIZE FAILURES OF FIXATION OF UNSTABLE INTERTROCHANTERIC FRACTURES [J].
GUNDLE, R ;
GARGAN, MF ;
SIMPSON, AHRW .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1995, 26 (09) :611-614