Microstructure and shear fracture characteristics of porous anodic TiO2 layer before and after hot water treatment

被引:25
作者
Chen, Z. X. [1 ]
Wang, W. X. [1 ]
Takao, Y. [1 ]
Matsubara, T. [1 ]
Ren, L. M. [1 ]
机构
[1] Kyushu Univ, Appl Mech Res Inst, Fukuoka 8168580, Japan
关键词
Titanium; Anodic spark oxidation; Hot water treatment; Microstructure; Fracture; OXIDE-FILMS; IN-VITRO; BIOMEDICAL APPLICATIONS; DENTAL IMPLANT; TISSUE REGENERATION; TITANIUM IMPLANTS; AMORPHOUS TITANIA; APATITE FORMATION; CRYSTALLIZATION; OXIDATION;
D O I
10.1016/j.apsusc.2011.03.101
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Porous TiO2 layer was fabricated on the surface of commercially pure titanium using an anodic spark oxidation technique for biomedical application, and subsequent hot water treatment was performed to modify the resultant oxide layer. The microstructure features and shear fracture characteristics of anodic oxide layer before and after water treatment were investigated. Results show that before water treatment, the oxide layer exhibited a porous surface with few nanometer features and consisted of poorly crystallized oxides, and an inner layer containing numerous cavities was observed near the oxide-substrate interface. After water treatment, the crystallinity degree of oxide layer was increased significantly and a nanostructured surface layer was obtained. The shear fracture characteristics of oxide layer were greatly influenced by its microstructure features. Before water treatment, the shear fracture took place primarily within the cavity-containing layer, resulting in a pitted fracture surface on the substrate side. However, after water treatment, the shear fracture occurred mainly along the bottom surface of nanostructured surface layer and the shear strength of oxide layer decreased obviously. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:7254 / 7262
页数:9
相关论文
共 40 条
[1]   Preparation of TEM samples of metal-oxide interface by the focused ion beam technique [J].
Abolhassani, S. ;
Gasser, Philippe .
JOURNAL OF MICROSCOPY-OXFORD, 2006, 223 :73-82
[2]   Evaluation of electrical breakdown of anodic films on titanium in phosphate-base solutions [J].
Afshar, A ;
Vaezi, MR .
SURFACE & COATINGS TECHNOLOGY, 2004, 186 (03) :398-404
[3]   OSSEOINTEGRATION AND ITS EXPERIMENTAL BACKGROUND [J].
BRANEMARK, PI .
JOURNAL OF PROSTHETIC DENTISTRY, 1983, 50 (03) :399-410
[4]  
BRUNETTE DM, 2001, TITANIUM MED MATE SC
[5]   Surface characteristics and in vitro biocompatibility of titanium anodized in a phosphoric acid solution at different voltages [J].
Chen, Z. X. ;
Takao, Y. ;
Wang, W. X. ;
Matsubara, T. ;
Ren, L. M. .
BIOMEDICAL MATERIALS, 2009, 4 (06)
[6]  
Chiesa R, 2003, J Appl Biomater Biomech, V1, P91
[7]   Advances in dental implant materials and tissue regeneration [J].
Ellingsen, JE ;
Thomsen, P ;
Lyngstadaas, SP .
PERIODONTOLOGY 2000, 2006, 41 :136-156
[8]   In vitro and in vivo behaviour of Ca- and P-enriched anodized titanium [J].
Fini, M ;
Cigada, A ;
Rondelli, G ;
Chiesa, R ;
Giardino, R ;
Giavaresi, G ;
Aldini, NN ;
Torricelli, P ;
Vicentini, B .
BIOMATERIALS, 1999, 20 (17) :1587-1594
[9]   Formation and adhesion of biomimetic hydroxyapatite deposited on titanium substrates [J].
Forsgren, Johan ;
Svahn, Fredrik ;
Jarmar, Tobias ;
Engqvist, Hakan .
ACTA BIOMATERIALIA, 2007, 3 (06) :980-984
[10]   Crystallization of anodic titania on titanium and its alloys [J].
Habazaki, H ;
Uozumi, M ;
Konno, H ;
Shimizu, K ;
Skeldon, P ;
Thompson, GE .
CORROSION SCIENCE, 2003, 45 (09) :2063-2073