Development of a phantom to validate high-dose-rate brachytherapy treatment planning systems with heterogeneous algorithms

被引:21
作者
Moura, Eduardo S. [1 ,2 ]
Micka, John A. [1 ]
Hammer, Cliff G. [1 ]
Culberson, Wesley S. [1 ]
DeWerd, Larry A. [1 ]
Rostelato, Maria Elisa C. M. [2 ]
Zeituni, Carlos A. [2 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53705 USA
[2] CNEN SP, Inst Pesquisas Energet & Nucl, BR-05508000 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
brachytherapy; Ir-192; treatment planning system; heterogeneities; RADIOCHROMIC FILM DOSIMETRY; PARTIAL BREAST IRRADIATION; MONTE-CARLO-SIMULATION; IONIZATION-CHAMBER; GAFCHROMIC FILM; AAPM PROTOCOL; PHOTON ENERGY; IR-192; SOURCE; RECOMMENDATIONS; DISTRIBUTIONS;
D O I
10.1118/1.4914390
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This work presents the development of a phantom to verify the treatment planning system (TPS) algorithms used for high-dose-rate (HDR) brachytherapy. It is designed to measure the relative dose in a heterogeneous media. The experimental details used, simulation methods, and comparisons with a commercial TPS are also provided. Methods: To simulate heterogeneous conditions, four materials were used: Virtual Water (TM) (VM), BR50/50 (TM), cork, and aluminum. The materials were arranged in 11 heterogeneity configurations. Three dosimeters were used to measure the relative response from a HDR Ir-192 source: TLD-100 (TM), Gafchromic (R) EBT3 film, and an Exradin (TM) A1SL ionization chamber. To compare the results from the experimental measurements, the various configurations were modeled in the PENELOPE/penEasy Monte Carlo code. Images of each setup geometry were acquired from a CT scanner and imported into BrachyVision (TM) TPS software, which includes a grid-based Boltzmann solver Acuros (TM). The results of the measurements performed in the heterogeneous setups were normalized to the dose values measured in the homogeneous Virtual Water (TM) setup and the respective differences due to the heterogeneities were considered. Additionally, dose values calculated based on the American Association of Physicists in Medicine-Task Group 43 formalism were compared to dose values calculated with the Acuros (TM) algorithm in the phantom. Calculated doses were compared at the same points, where measurements have been performed. Results: Differences in the relative response as high as 11.5% were found from the homogeneous setup when the heterogeneous materials were inserted into the experimental phantom. The aluminum and cork materials produced larger differences than the plastic materials, with the BR50/50 (TM) material producing results similar to the Virtual Water (TM) results. Our experimental methods agree with the PENELOPE/penEasy simulations for most setups and dosimeters. The TPS relative differences with the Acuros (TM) algorithm were similar in both experimental and simulated setups. The discrepancy between the BrachyVision (TM), Acuros (TM), and TG-43 dose responses in the phantom described by this work exceeded 12% for certain setups. Conclusions: The results derived from the phantom measurements show good agreement with the simulations and TPS calculations, using Acuros (TM) algorithm. Differences in the dose responses were evident in the experimental results when heterogeneous materials were introduced. These measurements prove the usefulness of the heterogeneous phantom for verification of HDR treatment planning systems based on model-based dose calculation algorithms. (C) 2015 American Association of Physicists in Medicine.
引用
收藏
页码:1566 / 1574
页数:9
相关论文
共 59 条
  • [51] Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations
    Rivard, MJ
    Coursey, BM
    DeWerd, LA
    Hanson, WF
    Huq, MS
    Ibbott, GS
    Mitch, MG
    Nath, R
    Williamson, JF
    [J]. MEDICAL PHYSICS, 2004, 31 (03) : 633 - 674
  • [52] Salvat F, 2011, PENELOPE-A Code System for Monte Carlo Simulation of Electron and Photon Transport
  • [53] Direct measurement of absorbed dose to water in HDR 192Ir brachytherapy: Water calorimetry, ionization chamber, Gafchromic film, and TG-43
    Sarfehnia, Arman
    Kawrakow, Iwan
    Seuntjens, Jan
    [J]. MEDICAL PHYSICS, 2010, 37 (04) : 1924 - 1932
  • [54] A PENELOPE-based system for the automated Monte Carlo simulation of clinacs and voxelized geometries-application to far-from-axis fields
    Sempau, Josep
    Badal, Andreu
    Brualla, Lorenzo
    [J]. MEDICAL PHYSICS, 2011, 38 (11) : 5887 - 5895
  • [55] Monte Carlo calculated absorbed-dose energy dependence of EBT and EBT2 film
    Sutherland, J. G. H.
    Rogers, D. W. O.
    [J]. MEDICAL PHYSICS, 2010, 37 (03) : 1110 - 1116
  • [56] Benchmarking BrachyDose: Voxel based EGSnrc Monte Carlo calculations of TG-43 dosimetry parameters
    Taylor, R. E. P.
    Yegin, G.
    Rogers, D. W. O.
    [J]. MEDICAL PHYSICS, 2007, 34 (02) : 445 - 457
  • [57] Testing of the analytical anisotropic algorithm for photon dose calculation
    Van Esch, Ann
    Tillikainen, Laura
    Pyykkonen, Jukka
    Tenhunen, Mikko
    Helminen, Hannu
    Siljamaki, Sami
    Alakuijala, Jyrki
    Paiusco, Marta
    Iori, Mauro
    Huyskens, Dominique P.
    [J]. MEDICAL PHYSICS, 2006, 33 (11) : 4130 - 4148
  • [58] Monte Carlo dosimetric study of the medium dose rate CSM40 source
    Vijande, J.
    Granero, D.
    Perez-Calatayud, J.
    Ballester, F.
    [J]. APPLIED RADIATION AND ISOTOPES, 2013, 82 : 283 - 288
  • [59] Wilkinson D., 2006, BIOMED IMAGING INTER, V2, P1