Design of a Four-Branch LCL-Type Grid-Connecting Interface for a Three-Phase, Four-Leg Active Power Filter

被引:12
作者
Cao, Wu [1 ]
Liu, Kangli [1 ]
Ji, Yongchao [1 ]
Wang, Yigang [1 ]
Zhao, Jianfeng [1 ]
机构
[1] Southeast Univ, Sch Elect Engn, Nanjing 210096, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
IMPLEMENTATION;
D O I
10.3390/en8031606
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Compared with the three-phase, two-split-capacitor active power filter (3P2C-APF), the three-phase, four-leg active power filter (3P4L-APF) has been widely used in three-phase, four-wire grid utility for power quality control due to its numerous advantages, such as higher current output capability, particularly in phase N, lower current and easier voltage control on the DC-side. However, designing the grid-connecting interface, which is between the voltage source converter (VSC) and grid utility, is rather difficult due to the higher requirement for current ripple filtering in phase N, cross-coupling in four phases and lack of relevant design methodology and specification. In this paper, a four-branch LCL-type (4B-LCL) grid-connecting interface is proposed for 3P4L-APF, which features better current ripple filtering performance without decreasing the current output capability in all phases. First, this paper describes the mathematical models of 4B-LCL in the fully-complex-vector form from the zero and non-zero sequence perspective, resulting in two independent and uniform equivalent circuits without cross coupling terms. Then, the 4B-LCL parameter design method based on the most comprehensive performance index is proposed, including three main stages as the specification: performance index requirement determination, fulfillment of that requirement, and verification. Finally, the validity and effectiveness of the proposed design are proven by the simulated and experimental results of a 3P4L-APF with 4B-LCL.
引用
收藏
页码:1606 / 1627
页数:22
相关论文
共 25 条
[1]  
Ahmed K. H., 2007, P COMP POW EL GDANSK
[2]  
[陈瑶 Chen Yao], 2007, [电工技术学报, Transactions of China Electrotechnical Society], V22, P124
[3]   Design and Implementation of a Robust Current Controller for VSI Connected to the Grid Through an LCL Filter [J].
Gabe, Ivan Jorge ;
Montagner, Vinicius Foletto ;
Pinheiro, Humberto .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (5-6) :1444-1452
[4]   Digital repetitive control of a three-phase four-wire shunt active filter [J].
Grino, Robert ;
Cardoner, Rafael ;
Costa-Castello, Ramon ;
Fossas, Enric .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2007, 54 (03) :1495-1503
[5]  
Guo Wei-feng, 2010, Proceedings of the CSEE, V30, P42
[6]   PLL-less active power filter based on one-cycle control for compensating unbalanced loads in three-phase four-wire system [J].
Hirve, Sachine ;
Chatterjee, Kishore ;
Femandes, B. G. ;
Imayavaramban, M. ;
Dwari, Suman .
IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (04) :2457-2465
[7]  
Kanaan H. Y., 2008, P EL C AJ FRANC 5 7
[8]   Digital signal processor implementation and performance evaluation of split capacitor, four-leg and three H-bridge-based three-phase four-wire shunt active filters [J].
Khadkikar, V. ;
Chandra, A. ;
Singh, B. .
IET POWER ELECTRONICS, 2011, 4 (04) :463-470
[9]  
Le Jian, 2011, Proceedings of the CSEE, V31, P62
[10]  
Le Jian, 2007, Proceedings of the CSEE, V27, P85