The Effects of Structure Thickness, Air Gap Thickness and Silicon Type on the Performance of a Horizontal Electrothermal MEMS Microgripper

被引:14
作者
Cauchi, Marija [1 ]
Grech, Ivan [2 ]
Mallia, Bertram [3 ]
Mollicone, Pierluigi [1 ]
Sammut, Nicholas [2 ]
机构
[1] Univ Malta, Dept Mech Engn, Fac Engn, MSD-2080 Msida, Malta
[2] Univ Malta, Fac Informat & Commun Technol, Dept Microelect & Nanoelect, MSD-2080 Msida, Malta
[3] Univ Malta, Dept Met & Mat Engn, Fac Engn, MSD-2080 Msida, Malta
关键词
MEMS microgrippers; micromanipulation; red blood cells; electrothermal actuation; PolyMUMPs (TM); SOIMUMPs (TM); structure thickness; air gap thickness; polysilicon; single crystal silicon; POLYMERIC MICROGRIPPER; DRIVEN MICROGRIPPER; CELL MANIPULATION; DESIGN; FABRICATION;
D O I
10.3390/act7030038
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The ongoing development of microelectromechanical systems (MEMS) over the past decades has made possible the achievement of high-precision micromanipulation within the micromanufacturing, microassembly and biomedical fields. This paper presents different design variants of a horizontal electrothermally actuated MEMS microgripper that are developed as microsystems to micromanipulate and study the deformability properties of human red blood cells (RBCs). The presented microgripper design variants are all based on the U-shape 'hot and cold arm' actuator configuration, and are fabricated using the commercially available Multi-User MEMS Processes (MUMPS (R)) that are produced by MEMSCAP, Inc. (Durham, NC, USA) and that include both surface micromachined (PolyMUMPs (TM)) and silicon-on-insulator (SOIMUMPs (TM)) MEMS fabrication technologies. The studied microgripper design variants have the same in-plane geometry, with their main differences arising from the thickness of the fabricated structures, the consequent air gap separation between the structure and the substrate surface, as well as the intrinsic nature of the silicon material used. These factors are all inherent characteristics of the specific fabrication technologies used. PolyMUMPs (TM) utilises polycrystalline silicon structures that are composed of two free-standing, independently stackable structural layers, enabling the user to achieve structure thicknesses of 1.5 mu m, 2 mu m and 3.5 mu m, respectively, whereas SOIMUMPs (TM) utilises a 25 mu m thick single crystal silicon structure having only one free-standing structural layer. The microgripper design variants are presented and compared in this work to investigate the effect of their differences on the temperature distribution and the achieved end-effector displacement. These design variants were analytically studied, as well as numerically modelled using finite element analysis where coupled electrothermomechanical simulations were carried out in CoventorWare (R) (Version 10, Coventor, Inc., Cary, NC, USA). Experimental results for the microgrippers' actuation under atmospheric pressure were obtained via optical microscopy studies for the PolyMUMPs (TM) structures, and they were found to be conforming with the predictions of the analytical and numerical models. The focus of this work is to identify which one of the studied design variants best optimises the microgripper's electrothermomechanical performance in terms of a sufficient lateral tip displacement, minimum out-of-plane displacement at the arm tips and good heat transfer to limit the temperature at the cell gripping zone, as required for the deformability study of RBCs.
引用
收藏
页数:20
相关论文
共 50 条
[1]   Measurement and characterisation of displacement and temperature of polymer based electrothermal microgrippers [J].
Al-Zandi, Muaiyd H. M. ;
Wang, Changhai ;
Voicu, Rodica ;
Muller, Raluca .
MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2018, 24 (01) :379-387
[2]   Quantification of red blood cell deformation at high-hematocrit blood flow in microvessels [J].
Alizadehrad, Davod ;
Imai, Yohsuke ;
Nakaaki, Keita ;
Ishikawa, Takuji ;
Yamaguchi, Takami .
JOURNAL OF BIOMECHANICS, 2012, 45 (15) :2684-2689
[3]   Fabrication of Novel MEMS Microgrippers by Deep Reactive Ion Etching With Metal Hard Mask [J].
Bagolini, Alvise ;
Ronchin, Sabina ;
Bellutti, Pierluigi ;
Chiste, Matteo ;
Verotti, Matteo ;
Belfiore, Nicola Pio .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2017, 26 (04) :926-934
[4]  
Belfiore N.P., 2015, INT J MECH CONTROL, V16, P21
[5]   Measurement of the Anisotropy of Young's Modulus in Single-Crystal Silicon [J].
Boyd, Euan J. ;
Uttamchandani, Deepak .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2012, 21 (01) :243-249
[6]  
Cauchi M, 2016, P INT CAE C 2016 PAR, P1
[7]   Analytical, Numerical and Experimental Study of a Horizontal Electrothermal MEMS Microgripper for the Deformability Characterisation of Human Red Blood Cells [J].
Cauchi, Marija ;
Grech, Ivan ;
Mallia, Bertram ;
Mollicone, Pierluigi ;
Sammut, Nicholas .
MICROMACHINES, 2018, 9 (03)
[8]   Development of Micro-Grippers for Tissue and Cell Manipulation with Direct Morphological Comparison [J].
Cecchi, Rossana ;
Verotti, Matteo ;
Capata, Roberto ;
Dochshanov, Alden ;
Broggiato, Giovanni Battista ;
Crescenzi, Rocco ;
Balucani, Marco ;
Natali, Stefano ;
Razzano, Giovanna ;
Lucchese, Franco ;
Bagolini, Alvise ;
Bellutti, Pierluigi ;
Sciubba, Enrico ;
Belfiore, Nicola P. .
MICROMACHINES, 2015, 6 (11) :1710-1728
[9]   Elastic properties and representative volume element of polycrystalline silicon for MEMS [J].
Cho, S. W. ;
Chasiotis, I. .
EXPERIMENTAL MECHANICS, 2007, 47 (01) :37-49
[10]   Electrothermally activated SU-8 microgripper for single cell manipulation in solution [J].
Chronis, N ;
Lee, LP .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2005, 14 (04) :857-863