Transcatheter closure of a membranous ventricular septal defect in a 1.8-kg infant using Amplatzer Duct Occluder II additional size device

被引:2
作者
Champaneri, Bhavik [1 ]
Kappanayil, Mahesh [1 ]
Kumar, Raman K. [1 ]
机构
[1] Amrita Inst Med Sci, Dept Pediat Cardiol, Kochi 682041, Kerala, India
关键词
Ventricular septal defect; transcatheter; infant; ARTERIOSUS;
D O I
10.1017/S1047951117000695
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Catheter closure of membranous ventricular septal defects is generally not considered feasible in small infants. We report the successful closure of a membranous ventricular septal defect in a 1.8-kg infant with bilateral femoral artery occlusion using Amplatzer Duct Occluder II additional size device. The ventricular septal defect was crossed from the right ventricle, and the device was deployed using transthoracic echocardiographic guidance.
引用
收藏
页码:1437 / 1440
页数:4
相关论文
共 5 条
[1]   Closure of a large perimembranous ventricular septal defect in a 4.8 kg baby with Down syndrome using a duct occluder [J].
Alghamdi, Mohammed H. ;
Galal, M. O. ;
Al-Habshan, Fahad ;
AL-Mutairi, Mansour .
JOURNAL OF THE SAUDI HEART ASSOCIATION, 2014, 26 (02) :111-116
[2]   DESCRIPTION OF VENTRICULAR SEPTAL-DEFECTS - OR HOW LONG IS A PIECE OF STRING [J].
ANDERSON, RH ;
BECKER, AE ;
TYNAN, M .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 1986, 13 (03) :267-278
[3]   Transcatheter Occlusion of Patent Ductus Arteriosus in Pre-Term Infants [J].
Francis, Edwin ;
Singhi, Anil Kumar ;
Lakshmivenkateshaiah, Srinivas ;
Kumar, Raman Krishna .
JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (05) :550-555
[4]   Comparison of percutaneous device closure versus surgical closure of peri-membranous ventricular septal defects: A systematic review and meta-analysis [J].
Saurav, Alok ;
Kaushik, Manu ;
Alla, Venkata Mahesh ;
White, Michael D. ;
Satpathy, Ruby ;
Lanspa, Thomas ;
Mooss, Aryan N. ;
DelCore, Michael G. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2015, 86 (06) :1048-1056
[5]   Closure of Patent Ductus Arteriosus in Children, Small Infants, and Premature Babies with Amplatzer Duct Occluder II Additional Sizes: Multicenter Study [J].
Sungur, Metin ;
Karakurt, Cemsit ;
Ozbarlas, Nazan ;
Baspinar, Osman .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 82 (02) :245-252