Respiratory-gated (4D) contrast-enhanced FDG PET-CT for radiotherapy planning of lower oesophageal carcinoma: feasibility and impact on planning target volume

被引:8
作者
Scarsbrook, Andrew [1 ,2 ,3 ]
Ward, Gillian [4 ]
Murray, Patrick [5 ]
Goody, Rebecca [5 ]
Marshall, Karen [1 ,2 ]
McDermott, Garry [2 ,4 ]
Prestwich, Robin [5 ]
Radhakrishna, Ganesh [6 ]
机构
[1] Leeds Teaching Hosp NHS Trust, Dept Radiol, Leeds, W Yorkshire, England
[2] Leeds Teaching Hosp NHS Trust, St Jamess Univ Hosp, Dept Nucl Med, Level 1,Bexley Wing,Beckett St, Leeds LS9 7TF, W Yorkshire, England
[3] Univ Leeds, Leeds Inst Canc & Pathol, Leeds, W Yorkshire, England
[4] Leeds Teaching Hosp NHS Trust, Dept Med Phys & Engn, Leeds, W Yorkshire, England
[5] Leeds Teaching Hosp NHS Trust, Dept Clin Oncol, Leeds, W Yorkshire, England
[6] Christie Hosp, Wilmslow Rd, Manchester M20 4BX, Lancs, England
关键词
FDG pet-Ct; Oesophageal carcinoma; Radiotherapy treatment planning; Four-dimensional CT; Target volume definition; EMISSION TOMOGRAPHY/COMPUTED TOMOGRAPHY; MAXIMUM INTENSITY PROJECTION; GROSS TUMOR VOLUME; RADIATION TREATMENT; CANCER; MOTION; DELINEATION; NEOSCOPE;
D O I
10.1186/s12885-017-3659-9
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: To assess the feasibility and potential impact on target delineation of respiratory-gated (4D) contrast-enhanced (18)Fluorine fluorodeoxyglucose (FDG) positron emission tomography - computed tomography (PET-CT), in the treatment planning position, for a prospective cohort of patients with lower third oesophageal cancer. Methods: Fifteen patients were recruited into the study. Imaging included 4D PET-CT, 3D PET-CT, endoscopic ultrasound and planning 4D CT. Target volume delineation was performed on 4D CT, 4D CT with co-registered 3D PET and 4D PET-CT. Planning target volumes (PTV) generated with 4D CT (PTV4DCT), 4D CT co-registered with 3D PET-CT (PTV3DPET4DCT) and 4D PET-CT (PTV4DPETCT) were compared with multiple positional metrics. Results: Mean PTV4DCT, PTV3DPET4DCT and PTV4DPETCT were 582.4 +/- 275.1 cm(3), 472.5 +/- 193.1 cm(3) and 480.6 +/- 236.9 cm(3) respectively (no significant difference). Median DICE similarity coefficients comparing PTV4DCT with PTV3DPET4DCT, PTV4DCT with PTV4DPETCT and PTV3DPET4DCT with PTV4DPETCT were 0.85 (range 0.65-0.9), 0.85 (range 0.69-0.9) and 0.88 (range 0.79-0.9) respectively. The median sensitivity index for overlap comparing PTV4DCT with PTV3DPET4DCT, PTV4DCT with PTV4DPETCT and PTV3DPET4DCT with PTV4DPETCT were 0.78 (range 0.65-0.9), 0.79 (range 0.65-0.9) and 0.89 (range 0.68-0.94) respectively. Conclusions: Planning 4D PET-CT is feasible with careful patient selection. PTV generated using 4D CT, 3D PET-CT and 4D PET-CT were of similar volume, however, overlap analysis demonstrated that approximately 20% of PTV3DPETCT and PTV4DPETCT are not included in PTV4DCT, leading to under-coverage of target volume and a potential geometric miss. Additionally, differences between PTV3DPET4DCT and PTV4DPETCT suggest a potential benefit for 4D PET-CT.
引用
收藏
页数:8
相关论文
共 29 条
[1]  
Aristophanous M, 2012, INT J RADIAT ONCOL, V82, P99
[2]   Dosimetric Analysis of Esophagus Plans Using 3-Dimensional Versus 4-Dimensional Computed Tomography Planning Scans Within the UK NeoScope Trial [J].
Bowden, C. N. ;
Selby, A. ;
Webster, R. ;
Radhakrishna, G. ;
Jones, G. ;
Crosby, T. ;
Gwynne, S. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02) :E643-E643
[3]   Validation of a 4D-PET Maximum Intensity Projection for Delineation of an Internal Target Volume [J].
Callahan, Jason ;
Kron, Tomas ;
Schneider-Kolsky, Michal ;
Dunn, Leon ;
Thompson, Mick ;
Siva, Shankar ;
Aarons, Yolanda ;
Binns, David ;
Hicks, Rodney J. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 86 (04) :749-754
[4]   Esophageal motion during radiotherapy: quantification and margin implications [J].
Cohen, R. J. ;
Paskalev, K. ;
Litwin, S. ;
Price, R. A., Jr. ;
Feigenberg, S. J. ;
Konski, A. A. .
DISEASES OF THE ESOPHAGUS, 2010, 23 (06) :473-479
[5]   Chemoradiotherapy with or without cetuximab in patients with oesophageal cancer (SCOPE1): a multicentre, phase 2/3 randomised trial [J].
Crosby, Thomas ;
Hurt, Christopher N. ;
Falk, Stephen ;
Gollins, Simon ;
Mukherjee, Somnath ;
Staffurth, John ;
Ray, Ruby ;
Bashir, Nadim ;
Bridgewater, John A. ;
Geh, J. Ian ;
Cunningham, David ;
Blazeby, Jane ;
Roy, Rajarshi ;
Maughan, Tim ;
Griffiths, Gareth .
LANCET ONCOLOGY, 2013, 14 (07) :627-637
[6]   MEASURES OF THE AMOUNT OF ECOLOGIC ASSOCIATION BETWEEN SPECIES [J].
DICE, LR .
ECOLOGY, 1945, 26 (03) :297-302
[7]  
Figura N, 2013, Pract Radiat Oncol, V3, pS34, DOI 10.1016/j.prro.2013.01.116
[8]   Pragmatic staging of oesophageal cancer using decision theory involving selective endoscopic ultrasonography, PET and laparoscopy [J].
Findlay, J. M. ;
Bradley, K. M. ;
Maile, E. J. ;
Braden, B. ;
Maw, J. ;
Phillips-Hughes, J. ;
Gillies, R. S. ;
Maynard, N. D. ;
Middleton, M. R. .
BRITISH JOURNAL OF SURGERY, 2015, 102 (12) :1488-1499
[9]   Comparative evaluation of CT-based and respiratory-gated PET/CT-based planning target volume (PTV) in the definition of radiation treatment planning in lung cancer: preliminary results [J].
Guerra, Luca ;
Meregalli, Sofia ;
Zorz, Alessandra ;
Niespolo, Rita ;
De Ponti, Elena ;
Elisei, Federica ;
Morzenti, Sabrina ;
Brenna, Sarah ;
Crespi, Andrea ;
Gardani, Gianstefano ;
Messa, Cristina .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 (04) :702-710
[10]   Geometrical differences in target volumes based on 18F-fluorodeoxyglucose positron emission tomography/computed tomography and four-dimensional computed tomography maximum intensity projection images of primary thoracic esophageal cancer [J].
Guo, Y. ;
Li, J. ;
Wang, W. ;
Zhang, Y. ;
Wang, J. ;
Duan, Y. ;
Shang, D. ;
Fu, Z. .
DISEASES OF THE ESOPHAGUS, 2014, 27 (08) :744-750