Assessment of global right ventricular function on 64-MDCT compared with MRI

被引:66
作者
Plumhans, Cedric [1 ]
Muehlenbruch, Georg [1 ]
Rapaee, Annuar [2 ]
Sim, Kui-Hian [2 ]
Seyfarth, Tobias [3 ]
Guenther, Rolf W. [1 ]
Mahnken, Andreas H. [1 ]
机构
[1] Univ Hosp, Rhein Westfal TH Aachen, Dept Diagnost Radiol, D-52057 Aachen, Germany
[2] Sarwak Gen Hosp, Dept Cardiol, Sarawak, Malaysia
[3] Siemens Med Solut, Erlangen, Germany
关键词
cardiac imaging; heart disease; MDCT; MRI; right ventricular function;
D O I
10.2214/AJR.07.3022
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The aim of this study was to compare ECG-gated 64-MDCT with MRI for the assessment of global right ventricular ( RV) function from coronary CT angiography data. SUBJECTS AND METHODs. Thirty-eight patients ( 25 men, 13 women; mean age +/- SD, 55.0 +/- 8.8 years) with suspected coronary artery disease underwent contrast-enhanced 64-MDCT ( 64 x 0.6 mm, 120 kV, 770 mAs(eff)) and 1.5-T MRI ( balanced fast-field echo; TR/TE, 3.3/1.6; flip angle, 60; 50 phases). Double oblique short-axis MDCT and MR images were used for further analysis. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), and ejection fraction (EF) were computed from manually drawn endocardial contours of the right ventricle. For statistical analysis, repeated-measures analysis of variance and Pearson's correlation coefficients were calculated. Bland-Altman plots were computed. RESULTS. In general, RV volumes calculated from 64-MDCT agreed well with those calculated from MRI. The mean EF (+/- SD) calculated from MDCT and MRI was 51.0% +/- 7.8% and 51.4% +/- 7.3%, respectively. An excellent correlation was observed for EDV (r=0.99), ESV (r=0.98), SV (r=0.98), and EF (r=0.97). Bland-Altman plots showed no systematic variation between MDCT and MRI data. No statistically significant differences (p <= 0.05) between the techniques were found. CONCLUSION. Although contrast injection is optimized for visualization of the coronary arteries, retrospectively ECG-gated 64-MDCT permits reliable assessment of global RV function.
引用
收藏
页码:1358 / 1361
页数:4
相关论文
共 23 条
[1]   Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclide ventriculography and cardiovascular magnetic resonance - Are they interchangeable? [J].
Bellenger, NG ;
Burgess, MI ;
Ray, SG ;
Lahiri, A ;
Coats, AJS ;
Cleland, JGF ;
Pennell, DJ .
EUROPEAN HEART JOURNAL, 2000, 21 (16) :1387-1396
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Evaluation of biventricular ejection fraction with ECG-gated 16-slice CT: preliminary findings in acute pulmonary embolism in comparison with radionuclide ventriculography [J].
Coche, E ;
Vlassenbroek, A ;
Roelants, V ;
D'Hoore, W ;
Verschuren, F ;
Goncette, L ;
Maldague, B .
EUROPEAN RADIOLOGY, 2005, 15 (07) :1432-1440
[4]   Evaluation of global and regional left ventricular function with 16-slice computed tomography, biplane cineventriculography, and two-dimensional transthoracic echocardiography -: Comparison with magnetic resonance imaging [J].
Dewey, Marc ;
Mueller, Mira ;
Eddicks, Stephan ;
Schnapauff, Dirk ;
Teige, Florian ;
Rutsch, Wolfgang ;
Borges, Adrian C. ;
Hamm, Bernd .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (10) :2034-2044
[5]   MDCT assessment of right ventricular systolic function [J].
Dogan, H ;
Kroft, LJM ;
Bax, JJ ;
Schuijf, JD ;
van der Geest, RJ ;
Doornbos, J ;
de Roos, A .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (06) :S366-S370
[6]   Right ventricular function in patients with acute pulmonary embolism: Analysis with electrocardiography-synchronized multi-detector row CT [J].
Dogan, Halil ;
Kroft, Lucia J. M. ;
Huisman, Menno V. ;
van der Geest, Rob J. ;
de Roos, Albert .
RADIOLOGY, 2007, 242 (01) :78-84
[7]   Left ventricular function studied with MDCT [J].
Juergens, KU ;
Fischbach, R .
EUROPEAN RADIOLOGY, 2006, 16 (02) :342-357
[8]   Using ECG-gated multicletector CT to evaluate global left ventricular myocardial function in patients with coronary artery disease [J].
Juergens, KU ;
Grude, M ;
Fallenberg, EM ;
Opitz, C ;
Wichter, T ;
Heindel, W ;
Fischbach, R .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (06) :1545-1550
[9]   Assessment of right ventricular function by 16-detector-row CT: comparison with magnetic resonance imaging [J].
Koch, K ;
Oellig, F ;
Oberholzer, K ;
Bender, P ;
Kunz, P ;
Mildenberger, P ;
Hake, U ;
Kreitner, KF ;
Thelen, M .
EUROPEAN RADIOLOGY, 2005, 15 (02) :312-318
[10]   Right ventricular dysfunction assessed by cardiovascular magnetic resonance imaging predicts poor prognosis late after myocardial infarction [J].
Larose, Eric ;
Ganz, Peter ;
Reynolds, H. Glenn ;
Dorbala, Sharmila ;
Di Carli, Marcelo F. ;
Brown, Kenneth A. ;
Kwong, Raymond Y. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (08) :855-862