Head and neck lesions: Characterization with diffusion-weighted echo-planar MR imaging

被引:431
作者
Wang, JC
Takashima, S
Takayama, F
Kawakami, H
Saito, A
Matsushita, T
Momose, M
Ishiyama, T
机构
[1] Shinshu Univ, Sch Med, Dept Radiol, Matsumoto, Nagano 3908621, Japan
[2] Shinshu Univ, Sch Med, Dept Otolaryngol, Matsumoto, Nagano 3908621, Japan
关键词
head and neck neoplasms; MR; magnetic resonance (MR); diffusion study; echo planar;
D O I
10.1148/radiol.2202010063
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate whether apparent diffusion coefficients (ADCs) calculated from diffusion-weighted echo-planar magnetic resonance (MR) images can be used to characterize head and neck lesions. MATERIALS AND METHODS: Diffusion-weighted echo-planar MR imaging was performed with a 1.5-T MR unit in 97 head and neck lesions in 97 patients. Images were obtained with a diffusion-weighted factor, factor b, of 0, 500, and 1,000 sec/mm(2) and an ADC map was constructed. The ADCs of lesions, cerebrospinal fluid, and spinal cord were calculated. RESULTS: Acceptable images for ADC measurement were obtained in 81 (84%) patients. The mean ADC of malignant lymphomas, (0.66 +/- 0.17[SD]) X 10(-3) mm(2)/sec (n = 13), was significantly smaller (P < .001) than that of carcinomas. The mean ADC of carcinomas, (1.13 +/- 0.43) X 10(-3) mm(2)/sec (n = 36), was significantly smaller (P = .002) than that of benign solid tumors. The mean ADC of benign solid tumors, (1.56 +/- 0.51) X 10(-3) mm(2)/sec (n = 22), was significantly smaller (P = .035) than that of benign cystic lesions, (2.05 +/- 0.62) X 10(-3) mm(2)/sec (n = 10). No significant differences were seen in the mean ADC of cerebrospinal fluid and of spinal cord among four groups of lesions. When an ADC smaller than 1.22 X 10(-3) mm(2)/sec was used for predicting malignancy, the highest accuracy of 86%, with 84% sensitivity and 91% specificity, was obtained. CONCLUSION: Measurement of ADCs may be used to characterize head and neck lesions.
引用
收藏
页码:621 / 630
页数:10
相关论文
共 26 条
  • [21] THOMSEN C, 1987, ACTA RADIOL, V28, P353
  • [22] MR-IMAGING OF HIGH-GRADE CEREBRAL GLIOMAS - VALUE OF DIFFUSION-WEIGHTED ECHOPLANAR PULSE SEQUENCES
    TIEN, RD
    FELSBERG, GJ
    FRIEDMAN, H
    BROWN, M
    MACFALL, J
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (03) : 671 - 677
  • [23] CERVICAL LYMPH-NODE METASTASIS - ASSESSMENT OF RADIOLOGIC CRITERIA
    VANDENBREKEL, MWM
    STEL, HV
    CASTELIJNS, JA
    NAUTA, JJP
    VANDERWAAL, I
    VALK, J
    MEYER, CJLM
    SNOW, GB
    [J]. RADIOLOGY, 1990, 177 (02) : 379 - 384
  • [24] ACUTE HUMAN STROKE STUDIED BY WHOLE-BRAIN ECHO-PLANAR DIFFUSION-WEIGHTED MAGNETIC-RESONANCE-IMAGING
    WARACH, S
    GAA, J
    SIEWERT, B
    WIELOPOLSKI, P
    EDELMAN, RR
    [J]. ANNALS OF NEUROLOGY, 1995, 37 (02) : 231 - 241
  • [25] Mucin-producing tumor of the pancreas: Diagnostic value of diffusion-weighted echo-planar MR imaging
    Yamashita, Y
    Namimoto, T
    Mitsuzaki, K
    Urata, J
    Tsuchigame, T
    Takahashi, M
    Ogawa, M
    [J]. RADIOLOGY, 1998, 208 (03) : 605 - 609
  • [26] Head and neck lesions - Radiologic-pathologic correlations
    Yousem, DM
    Montone, KT
    [J]. RADIOLOGIC CLINICS OF NORTH AMERICA, 1998, 36 (05) : 983 - +