Simultaneous determination of potassium and total fluoride in toothpastes using a SIA system with two potentiometric detectors

被引:12
作者
Perez-Olmos, R. [1 ]
Soto, J. C. [1 ]
Zarate, N. [1 ]
Diez, I. [1 ]
机构
[1] Univ Basque Country, EUITI, Lab Quim Analit, Bilbao 48012, Spain
关键词
toothpaste; potassium and fluoride simultaneous determination; SIA; potentiometric detection;
D O I
10.1016/j.jpba.2007.11.028
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sequential injection analysis (SIA) system has been developed for the first time to quantify potassium and total fluoride in toothpastes and gels used to prevent both dentinal hypersensitivity and dental caries. To enable this simultaneous determination, potentiometric detection, using a conventional fluoride electrode and a tubular potassium selective electrode, formed by a PVC membrane containing valinomycin as ionophore, was carried out. A manifold that uses a three-way solenoid valve was designed. The former under binary sampling conditions, provides reproducible mixing ratios of two solutions. This fact facilitates that the system automatically generates, on-line, the calibration curves required by the analytical procedure. The calibration ranged from 1.0 x 10(-4) to 1.0 x 10(-3) mol L-1 for both potassium and total fluoride determinations. The R.S.D. (11 readings) resulted to be less than 1.5% for both determinations. Off-line studies related to the dissolution of the solid samples, the transformation of monofluorophosphate in fluoride, the elimination of organic matrix interference onto the plastic membrane of the potassium electrode, and the selection of the most adequate TISAB solution for fluoride determination, were also considered. A sampling rate of 18 samples h(-1) for both determinations was attained, their precisions and accuracies being statistically indistinguishable from those achieved by atomic emission spectroscopy (for potassium determination) and by a conventional batch potentiometry (for total fluoride determination) adopted as reference techniques. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:170 / 176
页数:7
相关论文
共 52 条
[1]   FLOW-THROUGH TUBULAR PVC MATRIX MEMBRANE-ELECTRODE WITHOUT INNER REFERENCE SOLUTION FOR FLOW-INJECTION ANALYSIS [J].
ALEGRET, S ;
ALONSO, J ;
BARTROLI, J ;
PAULIS, JM ;
LIMA, JLFC ;
MACHADO, AASC .
ANALYTICA CHIMICA ACTA, 1984, 164 (OCT) :147-152
[2]  
ALEGRET S, 1987, QUIM ANAL, V6, P278
[3]   Simultaneous determination of chloride and fluoride ions in waters by sequential injection analysis [J].
Alpizar, J ;
Crespi, A ;
Cladera, A ;
Forteza, R ;
Cerda, V .
ELECTROANALYSIS, 1996, 8 (11) :1051-1054
[4]   Determination of chloride by multisyringe flow injection analysis and sequential injection analysis with potentiometric detection [J].
Andrade-Eiroa, A ;
Erustes, JA ;
Forteza, R ;
Cerdá, V ;
Lima, JLFC .
ANALYTICA CHIMICA ACTA, 2002, 467 (1-2) :25-33
[5]  
[Anonymous], 1987, ANALYST, V112, P199
[6]   Application of sequential injection analysis to the assay of lead retention characteristics by poly(vinylpyrrolidone):: Trace analysis of lead in waters [J].
Araújo, AN ;
Costa, RCC ;
Lima, JLFC .
ANALYTICAL SCIENCES, 1999, 15 (10) :991-994
[7]  
BLACK S A, 1989, Analytical Proceedings, V26, P67
[8]  
BUSHEE EJ, 1971, J DENT CHILD, V38, P279
[9]   Determination of total fluoride in oral products by using of potentiometry with ion selective electrode:: A critical study [J].
Cassella, RJ ;
Araújo, HD ;
da Silva, AI ;
Cruz, MB ;
Campos, MD .
ANALYTICAL LETTERS, 2000, 33 (05) :819-829
[10]   SIMULTANEOUS DETERMINATION OF POTASSIUM-NITRATE AND SODIUM MONOFLUOROPHOSPHATE IN DENTIFRICES BY SINGLE COLUMN ION CHROMATOGRAPHY [J].
CHEN, SS ;
LULLA, H ;
SENA, FJ ;
REYNOSO, V .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1985, 23 (08) :355-359