Histologic and histomorphometric analysis of three types of dental implants following 18 months of occlusal loading: a preliminary study in baboons

被引:38
作者
Watzak, G
Zechner, W
Ulm, C
Tangl, S
Tepper, G
Watzek, G
机构
[1] Med Univ Vienna, Dept Oral Surg, Clin Dent, A-1090 Vienna, Austria
[2] Ludwig Boltzmann Inst Oral Implantol, Vienna, Austria
[3] Med Univ Vienna, Dept Periodontol, Clin Dent, Vienna, Austria
关键词
animal study; cylindrical implants; functional loaded implants; implant surface; screw-shaped implants;
D O I
10.1111/j.1600-0501.2005.01155.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this study was to determine the percentage of 'bone area' (BA) and 'bone-to-implant contact' (BIC) of dental implants with different designs and surface modifications after functional loading. Three types of dental implants with fixed partial dentures were placed in the posterior jaws of adult baboons (commercially pure titanium (CpTi) screws, grit-blasted acid-etched (GBAE) screws, and titanium plasma-sprayed (TPS) cylinders), three of the same design per quadrant. After 18 months of functional loading, all implants investigated were successfully integrated in the jawbone and histologic and histomorphometric analyses were carried out. Statistical evaluation was performed with a mixed model with data given as least-square means and standard errors of the mean (SEM). Histologically, direct BIC without connective tissue interposed between implant surfaces and peri-implant bone was seen. Analysis of BA within 1 mm around implants showed significant differences between CpTi (50.5%) and TPS (39.7%) (+/- 2.72 SEM; P < 0.01) in the maxilla. To account for the different implant designs, absolute BIC was calculated. Significant differences were found between CpTi (23.9 mm) and TPS (15.1 mm) and between GBAE (27.2 mm) and TPS (15.1 mm) (+/- 1.05 SEM; P < 0.01) in the maxilla and between GBAE (26.5 mm) and TPS (19.6 mm) (+/- 1.42 SEM; P < 0.01) in the mandible. Overall, the data indicate that, in the maxilla, screw-shaped implants showed more absolute BIC than cylindrical implants, which had less maxillary than mandibular absolute BIC after 18 months of functional loading.
引用
收藏
页码:408 / 416
页数:9
相关论文
共 39 条
[1]  
Ashman R B, 1987, Adv Dent Res, V1, P64
[2]   OSSEOINTEGRATION AND ITS EXPERIMENTAL BACKGROUND [J].
BRANEMARK, PI .
JOURNAL OF PROSTHETIC DENTISTRY, 1983, 50 (03) :399-410
[3]  
Brown R., 1999, HOMOL HOMOTOPY APPL, V1, P1, DOI [DOI 10.4310/HHA.1999.V1.N1.A1, 10.4310/HHA.1999.v1.n1.a1, 10.4310/HHA.1999.v1.n1.a1.165,171,173,221]
[4]  
Brunski J B, 1988, Int J Oral Maxillofac Implants, V3, P85
[5]   IMPLANT FIXATION IMPROVED BY CLOSE FIT - CYLINDRICAL IMPLANT - BONE INTERFACE STUDIED IN RABBITS [J].
CARLSSON, L ;
ROSTLUND, T ;
ALBREKTSSON, B ;
ALBREKTSSON, T .
ACTA ORTHOPAEDICA SCANDINAVICA, 1988, 59 (03) :272-275
[6]  
Carr AB, 1997, INT J ORAL MAX IMPL, V12, P777
[7]  
Carr AB, 2000, INT J ORAL MAX IMPL, V15, P785
[8]  
Caudill R, 2000, INT J PERIODONT REST, V20, P307
[9]  
Cochran DL, 1998, J BIOMED MATER RES, V40, P1, DOI 10.1002/(SICI)1097-4636(199804)40:1<1::AID-JBM1>3.0.CO
[10]  
2-Q