Toward a Wirelessly Powered On-Lens Intraocular Pressure Monitoring System

被引:26
作者
Chiou, Jin-Chern [1 ]
Hsu, Shun-Hsi [1 ]
Liao, Yu-Te [1 ]
Huang, Yu-Chieh [2 ]
Yeh, Guan-Ting [2 ]
Kuei, Cheng-Kai [2 ]
Dai, Kai-Shiun [2 ]
机构
[1] Natl Chiao Tung Univ, Dept Elect & Comp Engn, Hsinchu 30010, Taiwan
[2] Natl Chiao Tung Univ, Inst Elect Control Engn, Hsinchu 300, Taiwan
关键词
Capacitance-to-digital converter (CDC); capacitive sensor; soft contact lens; UHF RFID Class1 Gen2; HEALTH-CARE; ANTENNA; SENSOR; CIRCUIT; DESIGN;
D O I
10.1109/JBHI.2016.2594058
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents a wireless on-lens intraocular pressure monitoring system, comprising a capacitance-to-digital converter and a wirelessly powered radio-frequency identification (RFID)-compatible communication system, for sensor control and data communication. The capacitive sensor was embedded on a soft contact lens of 200 mu m thickness using commercially available biocompatible lens material, to improve compliance and reduce user discomfort. The sensor chip was shown to achieve effective number of bits greater than 10 over a capacitance range up to 50 pF while consuming only 64-mu W power. The on-lens capacitive sensor could detect dielectric variation caused by changes in water content from a distance of 2 cm by using incident power from an RFID reader at 20 dBm. The maximum detectable distance was 11 cm with 30-dBm incident RF power. The rise in eye tissue temperature under 30-dBm RF exposure over an interval of 1 s was simulated and found to be less than 0.01 degrees C.
引用
收藏
页码:1216 / 1224
页数:9
相关论文
共 31 条
[1]  
[Anonymous], 2016, CISC RFID XPLORER EQ
[2]  
[Anonymous], P 7 ACM WORKSH HOT T
[3]  
[Anonymous], 1999, IEEE STANDARD C951
[4]  
Chen G., 2011, 2011 IEEE International Solid-State Circuits Conference (ISSCC 2011), P310, DOI 10.1109/ISSCC.2011.5746332
[5]   Capacitive contact lens sensor for continuous non-invasive intraocular pressure monitoring [J].
Chen, Guo-Zhen ;
Chan, Ion-Seng ;
Lam, David C. C. .
SENSORS AND ACTUATORS A-PHYSICAL, 2013, 203 :112-118
[6]   Analysis of Antenna Coupling in Near-Field Communication Systems [J].
Chen, Yen-Sheng ;
Chen, Shih-Yuan ;
Li, Hsueh-Jyh .
IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2010, 58 (10) :3327-3335
[7]   Design of Miniaturized Antenna and Power Harvester Circuit on the Enucleated Porcine Eyes [J].
Cheng, Hui-Wen ;
Yu, Tsung-Chi ;
Huang, Hong-Yi ;
Ting, Ssu-Han ;
Huang, Tzuen-Hsi ;
Chiou, Jin-Chern ;
Luo, Ching-Hsing .
IEEE ANTENNAS AND WIRELESS PROPAGATION LETTERS, 2014, 13 :1156-1159
[8]   A Miniature-Implantable RF-Wireless Active Glaucoma Intraocular Pressure Monitor [J].
Chow, Eric Y. ;
Chlebowski, Arthur L. ;
Irazoqui, Pedro P. .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2010, 4 (06) :340-349
[9]  
Donida A, 2015, ISSCC DIG TECH PAP I, V58, P392, DOI 10.1109/ISSCC.2015.7063091
[10]  
Faulkner A., 2014, P FLAIRS C, P1