Influence of dentin cavity surface finishing on micro-tensile bond strength of adhesives

被引:59
作者
Cardoso, Marcio V. [1 ,2 ]
Coutinho, Eduardo [1 ]
Ermis, R. Banu [1 ,3 ]
Poitevin, Andre [1 ]
Van Landuyt, Kirsten [1 ]
De Munck, Jan [1 ]
Carvalho, Rubens C. R. [2 ]
Van Meerbeek, Bart [1 ]
机构
[1] Catholic Univ Louvain, Sch Dent Oral Pathol & Maxillofacial Surg, Dept Conservat Dent, Leuven BIOMAT Res Cluster, B-3000 Louvain, Belgium
[2] Univ Sao Paulo, Sch Dent, Dept Restorat Dent, Sao Paulo, Brazil
[3] Suleyman Demirel Univ, Sch Dent, Dept Restorat Dent & Endodont, Isparta, Turkey
关键词
adhesion; dental adhesive; dentin; bond strength; smear layer; burs; ultra-sonoabrasion; lasers; cavity preparation; ultrastructure;
D O I
10.1016/j.dental.2007.04.011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The current trend toward minimal-invasive dentistry has introduced innovative techniques for cavity preparation. Chemical vapor deposition (CVD) and laser-irradiation technology have been employed as an alternative to the common use of regular burs in high-speed turbines. Objectives. The purpose of this study was to assess the influence of alternative techniques for cavity preparation on the bonding effectiveness of different adhesives to dentin, and to evaluate the morphological characteristics of dentin prepared with those techniques. Methods. One etch&rinse adhesive (OptiBond FL, Kerr) and three self-etch systems (Adper Prompt L-Pop, 3M ESPE; Clearfil SE Bond, Kuraray; Clearfil S3 Bond, Kuraray) were applied on dentin prepared with a regular bur in a turbine, with a CVD bur in a turbine, with a CVD tip in ultrasound and with an ErCr:YSGG laser. The micro-tensile bond strength (mu TBS) was determined after storage in water for 24 h at 37 degrees C, and morphological evaluation was performed by means of field -emission -gun scanning electron microscopy (Feg-SEM). Results. Feg-SEM evaluation revealed different morphological features on the dentin surface after the usage of both the conventional and alternative techniques for cavity preparation, more specifically regarding smear-layer thickness and surface roughness. CVD bur-cut, CVD ultra-sonoabraded and laser-irradiated dentin resulted in lower mu TBSs than conventionally bur-cut dentin, irrespective of the adhesive employed. Significance. The techniques, such as CVD diamond-bur cutting, CVD diamond ultra-sonoabrasion and laser-irradiation, used for cavity preparation may affect the bonding effectiveness of adhesives to dentin, irrespective of their acidity or approach. (C) 2007 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:492 / 501
页数:10
相关论文
共 34 条
  • [11] Ablation depths and morphological changes in human enamel and dentin after Er:YAG laser irradiation with or without water mist
    Hossain, M
    Nakamura, Y
    Yamada, Y
    Kimura, Y
    Nakamura, G
    Matsumoto, K
    [J]. JOURNAL OF CLINICAL LASER MEDICINE & SURGERY, 1999, 17 (03): : 105 - 109
  • [12] Hugo B, 1998, Pract Periodontics Aesthet Dent, V10, P353
  • [13] INOUE H, 2001, J ADHES DENT, V17, P122
  • [14] Surface roughness and bond strength of enamel to composite
    Jung, M
    Wehlen, LO
    Klimek, J
    [J]. DENTAL MATERIALS, 1999, 15 (04) : 250 - 256
  • [15] Kataumi M, 1998, DENT MATER J, V17, P125
  • [16] Bonding to dentin with a self-etching primer: the effect of smear layers
    Koibuchi, H
    Yasuda, N
    Nakabayashi, N
    [J]. DENTAL MATERIALS, 2001, 17 (02) : 122 - 126
  • [17] Clinical assessment of Er,Cr:YSGG laser application for cavity preparation
    Matsumoto, K
    Hossain, M
    Hossain, MMI
    Kawano, H
    Kimura, Y
    [J]. JOURNAL OF CLINICAL LASER MEDICINE & SURGERY, 2002, 20 (01): : 17 - 21
  • [18] Ogata M, 2001, OPER DENT, V26, P375
  • [19] The influence of the dentin smear layer on adhesion: a self-etching primer vs. a total-etch system
    Oliveira, SSA
    Pugach, MK
    Hilton, JF
    Watanabe, LG
    Marshall, SJ
    Marshall, GW
    [J]. DENTAL MATERIALS, 2003, 19 (08) : 758 - 767
  • [20] ULTRASONIC DISSECTION
    PAYNE, JH
    [J]. SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1994, 8 (05): : 416 - 418