Computerised measurements of QT dispersion in healthy subjects

被引:35
作者
Gang, Y [1 ]
Guo, XH [1 ]
Crook, R [1 ]
Hnatkova, K [1 ]
Camm, AJ [1 ]
Malik, M [1 ]
机构
[1] St George Hosp, Sch Med, Dept Cardiol Sci, London SW17 0RE, England
关键词
QT dispersion; reproducibility; automatic measurement; healthy subjects;
D O I
10.1136/hrt.80.5.459
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective-To assess the stability and reproducibility of computerised QT dispersion (QTd) measurement in healthy subjects, as this is presently being incorporated into commercial electrocardiographic systems. Methods-70 healthy volunteers (mean (SD) age 38 (10) years, 35 men, 35 women) with a normal 12 lead electrocardiogram (ECG) were studied. From each subject, 70 ECG recordings were taken using the MAC VU ECG recorder (Marquette). In study A, 50 ECGs were recorded in each subject: 10 supine, 10 sitting, 10 standing, 10 holding breath in maximum inspiration, and 10 holding breath in maximum expiration. After a mean interval of 8 (3) days (range 7 to 23), 10 recordings in supine and 10 in the standing position were repeated in each subject (study B). On measurements made using a research version of the commercial software without manual modification, the reproducibility of QTd was assessed by coefficient of variance (CV) and relative error, and comparisons made with other ECG indices. Results-(1) QTd measurements were stable and not influenced by changes in posture and respiratory cycle; (2) there was no difference in QTd measurements between men and women, or between age groups dichotomised at 35 years; (3) no correlation was found between QTd and heart rate or QT interval; (4) short term reproducibility of all QTd measurements (CV 15.6% to 43.8%) was worse than that of conventional ECG indices (CV 1.4% to 5.3%); (5) long term reproducibility of QTd measurements (relative error 27.4% to 31.0%) was also worse than that of conventional ECG indices (relative error 1.8% to 7.9%) (p < 0.0001); (6) the reproducibility of QTd measurements tended to increase when several serial recordings were averaged. Conclusions-Computerised measurements of global QTd and global QT-SD from 12 lead ECG by the MAC VU/QT Guard system are not significantly altered by changes in posture and respiration. The reproducibility of all QTd measurements is inferior to that of conventional ECG indices in healthy subjects.
引用
收藏
页码:459 / 466
页数:8
相关论文
共 21 条
  • [1] QT DISPERSION AND SUDDEN UNEXPECTED DEATH IN CHRONIC HEART-FAILURE
    BARR, CS
    NAAS, A
    FREEMAN, M
    LANG, CC
    STRUTHERS, AD
    [J]. LANCET, 1994, 343 (8893) : 327 - 329
  • [2] INFLUENCE OF THE AUTONOMIC NERVOUS-SYSTEM ON THE Q-T INTERVAL IN MAN
    BROWNE, KF
    ZIPES, DP
    HEGER, JJ
    PRYSTOWSKY, EN
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1982, 50 (05) : 1099 - 1103
  • [3] COMPARISON OF QT DISPERSION IN HYPERTROPHIC CARDIOMYOPATHY BETWEEN PATIENTS WITH AND WITHOUT VENTRICULAR ARRHYTHMIAS AND SUDDEN-DEATH
    BUJA, G
    MIORELLI, M
    TURRINI, P
    MELACINI, P
    NAVA, A
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (12) : 973 - 976
  • [4] SYMPATHETIC AND VAGAL INFLUENCES ON RATE-DEPENDENT CHANGES OF QT INTERVAL IN HEALTHY-SUBJECTS
    CAPPATO, R
    ALBONI, P
    PEDRONI, P
    GILLI, G
    ANTONIOLI, G
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (11) : 1188 - 1193
  • [5] DAY CP, 1990, BRIT HEART J, V63, P342
  • [6] QT-INTERVAL DISPERSION ON 12-LEAD ELECTROCARDIOGRAM IN NORMAL SUBJECTS - ITS REPRODUCIBILITY AND RELATION TO THE T-WAVE
    FEI, L
    STATTERS, DJ
    CAMM, AJ
    [J]. AMERICAN HEART JOURNAL, 1994, 127 (06) : 1654 - 1655
  • [7] Glancy JM, 1996, EUR HEART J, V17, P1035
  • [8] QT DISPERSION AND MORTALITY AFTER MYOCARDIAL-INFARCTION
    GLANCY, JM
    GARRATT, CJ
    WOODS, KL
    DEBONE, DP
    [J]. LANCET, 1995, 345 (8955): : 945 - 948
  • [9] QT dispersion and arrhythmic events in idiopathic dilated cardiomyopathy
    Grimm, W
    Steder, U
    Menz, V
    Hoffmann, J
    Maisch, B
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 (04) : 458 - 461
  • [10] PRECORDIAL QT INTERVAL DISPERSION AS A MARKER OF TORSADE-DE-POINTES - DISPARATE EFFECTS OF CLASS IA ANTIARRHYTHMIC DRUGS AND AMIODARONE
    HII, JTY
    WYSE, DG
    GILLIS, AM
    DUFF, HJ
    SOLYLO, MA
    MITCHELL, B
    [J]. CIRCULATION, 1992, 86 (05) : 1376 - 1382