Artificial chordae for mitral valve repair

被引:11
作者
Vendramin, Igor [1 ]
Milano, Aldo D. [2 ]
Pucci, Angela [3 ]
Lechiancole, Andrea [1 ]
Sponga, Sandro [1 ]
Bortolotti, Uberto [1 ]
Livi, Ugolino [1 ]
机构
[1] Univ Hosp, Cardiothorac Dept, Udine, Italy
[2] Univ Hosp, Div Cardiac Surg, Bari, Italy
[3] Univ Hosp, Div Pathol, Pisa, Italy
关键词
cardiovascular pathology; valve repair; replacement; EXPANDED POLYTETRAFLUOROETHYLENE NEOCHORDAE; EARLY RUPTURE; REPLACEMENT; REGURGITATION; PERICARDIUM; SUTURES; CALCIFICATION; MECHANISMS; EXPERIENCE; TENDINEAE;
D O I
10.1111/jocs.16937
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Mitral valve repair using expanded polytetrafluoroethylene sutures to replace mitral chordae tendineae is a well-established procedure. However, the incidence of neo-chordae failure causing recurrent mitral regurgitation is not well defined. Methods We have reviewed the reported cases of complications after mitral valve repair related to the use of neo-chordae. This study was mainly carried out through PubMed, Medline, and Google Chrome websites. Results We have identified a total of 26 patients presenting with rupture of polytetrafluoroethylene neo-chordae, mostly being described as isolated cases. Few other cases of recurrent mitral regurgitation with hemolysis were found, where reoperation was not caused by neo-chordal failure but most likely by technical errors. At pathological investigation the findings were substantially similar in all reported cases. The neo-chordae retained their length and pliability, became covered with host tissue and rupture was mainly related to suture size. Mild calcification was observed not interfering with chordal function; chordal infection did never occur. Conclusions The use of artificial neo-chordae provides excellent late results with durable mitral valve repair stability. Chordal rupture may occur late postoperatively leading to reoperation because of recurrent mitral regurgitation. Despite its rarity, this potential complication should not be overlooked during follow-up of patients after mitral valve repair using artificial neo-chordae.
引用
收藏
页码:3722 / 3728
页数:7
相关论文
共 43 条
[1]  
[Anonymous], 2015, PERFECT CLOSE
[2]   REPLACEMENT OF MITRAL-VALVE CHORDAE WITH AUTOLOGOUS PERICARDIUM IN DOGS [J].
BORTOLOTTI, U ;
GALLO, JI ;
GABBAY, S ;
FACTOR, SM ;
SISTO, D ;
FRATER, RWM .
THORACIC AND CARDIOVASCULAR SURGEON, 1984, 32 (01) :15-17
[3]  
Bortolotti U, 2012, J HEART VALVE DIS, V21, P440
[4]   Mitral Valve Repair With Artificial Chordae: A Review of Its History, Technical Details, Long-Term Results, and Pathology [J].
Bortolotti, Uberto ;
Milano, Aldo D. ;
Frater, Robert W. M. .
ANNALS OF THORACIC SURGERY, 2012, 93 (02) :684-691
[5]   Ruptured synthetic expanded polytetrafluoroethylene chordae tendinae [J].
Butany, J ;
Collins, MJ ;
David, TE .
CARDIOVASCULAR PATHOLOGY, 2004, 13 (03) :182-184
[6]  
CARPENTIER A, 1983, J THORAC CARDIOV SUR, V86, P323
[7]   Early rupture of an expanded polytetrafluoroethylene neochord after complex mitral valve repair: An electron microscopic analysis [J].
Castillo, Javier G. ;
Anyanwu, Anelechi C. ;
El-Eshmawi, Ahmed ;
Gordon, Ronald E. ;
Adams, David H. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 145 (03) :E29-E31
[8]  
Ceresa F., 2022, J BIOMED RES ENV SCI, V3, P111
[9]  
Coutinho GF, 2007, J HEART VALVE DIS, V16, P278
[10]  
DAVID TE, 1991, J THORAC CARDIOV SUR, V101, P495