Computer-generated real-time digital holography: first time use in clinical medical imaging

被引:84
作者
Bruckheimer, Elchanan [1 ,2 ]
Rotschild, Carmel [2 ,3 ]
Dagan, Tamir [1 ]
Amir, Gabriel [1 ]
Kaufman, Aviad [2 ]
Gelman, Shaul [2 ]
Birk, Einat [1 ]
机构
[1] Schneider Childrens Med Ctr Israel, Pediat Cardiol Sect, Petah Tiqwa, Israel
[2] Realview Med Imaging, Yokneam, Israel
[3] Technion, Dept Mech Engn, Haifa, Israel
关键词
Three dimensional; Echocardiography; Rotational angiography; Structural heart disease; 3D ROTATIONAL ANGIOGRAPHY; MITRAL-VALVE; ATRIAL-FIBRILLATION; AUGMENTED-REALITY; EXPERIENCE; EXPOSURE; ABLATION; GUIDANCE; SURGERY; REPAIR;
D O I
10.1093/ehjci/jew087
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Assessment of the feasibility of creating real-time interactive 3D digital holograms in a standard catheterization laboratory. 3D medical images are typically displayed and interacted with on 2D screens limiting their usefulness. A digital computer-generated real-time holographic display of patient's 3D data could provide a spatially accurate image with all the depth cues and afford interaction within the image. Methods and results We performed a feasibility study of creating real-time interactive 3D digital holograms with a purpose-built prototype using intraprocedural data from 3D rotational angiography and live 3D transesophageal echocardiography. The primary objective was to demonstrate that all the anatomical landmarks identified on standard imaging can be similarly identified using dynamic and static holographic images. The secondary objective was to demonstrate the usability of interactions with the image. Parameters were assessed by a rating scale. Eight patients were enrolled of whom five underwent transcatheter ASD closure using 3DTEE and three patients were evaluated by 3D rotational angiography. In all cases dynamic real-time and static 3D holograms were created in standard cath lab conditions. Four individual observers identified all anatomical landmarks on the holographic display independently from the 2D display. Interactions with the hologram including marking, cropping and rotation were performed. There were no adverse events. Conclusions This study demonstrates, for the first time, the feasibility of generating high quality, clinically relevant, 3D real-time colour dynamic holograms in a standard clinical setting with real patient volumetric data. The impact of computer-generated holography needs to be evaluated in controlled clinical trials.
引用
收藏
页码:845 / 849
页数:5
相关论文
共 27 条
[1]   A COMPARISON OF FLUOROSCOPY AND COMPUTED TOMOGRAPHY-DERIVED VOLUMETRIC MULTIPLE EXPOSURE TRANSMISSION HOLOGRAPHY FOR THE GUIDANCE OF LUMBAR PEDICLE SCREW INSERTION [J].
BENZEL, EC ;
RUPP, FW ;
MCCORMACK, BM ;
BALDWIN, NG ;
ANSON, JA ;
ADAMS, MS .
NEUROSURGERY, 1995, 37 (04) :711-716
[2]   Utility of Combined Two-Dimensional and Three-Dimensional Transesophageal Imaging for Catheter-Based Mitral Valve Clip Repair of Mitral Regurgitation [J].
Biner, Simon ;
Perk, Gila ;
Kar, Saibal ;
Rafique, Asim M. ;
Slater, James ;
Shiota, Takahiro ;
Hussaini, Asma ;
Chou, Stanley ;
Kronzon, Itzhak ;
Siegel, Robert J. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2011, 24 (06) :611-617
[3]   Comparison of 2D Digital Subtraction Angiography and 3D Rotational Angiography in the Evaluation of Dome-to-Neck Ratio [J].
Brinjikji, W. ;
Cloft, H. ;
Lanzino, G. ;
Kallmes, D. F. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (04) :831-834
[4]   First experience of 3D rotational angiography fusion with NavX electroanatomical mapping to guide catheter ablation of atrial fibrillation [J].
Carpen, Mahendra ;
Matkins, John ;
Syros, George ;
Gorey, Maxim V. ;
Alikhani, Zoubin ;
Wylie, John V. ;
Natan, Shaw R. ;
Griben, Andre ;
Hicks, Amy ;
Armstrong, James ;
Orlov, Michael V. .
HEART RHYTHM, 2013, 10 (03) :422-427
[5]   Early experience studying cerebral aneurysms with rotational and threedimensional angiography and review of CT and MR angiography literature [J].
Castaño-Duque, CH ;
Ruscalleda-Nadal, J ;
De Juan-Delago, M ;
Guardia-Mas, E ;
San Roman-Manzanera, L ;
Bartomeus-Jene, F ;
Molet-Teixido, J ;
Tresserras-Ribo, P ;
Pares-Muñoz, P ;
Laria, PC .
INTERVENTIONAL NEURORADIOLOGY, 2002, 8 (04) :377-391
[6]  
Chapron Julien, 2013, Glob Cardiol Sci Pract, V2013, P409, DOI 10.5339/gcsp.2013.49
[7]   Augmented-reality-based skills training for robot-assisted urethrovesical anastomosis: a multi-institutional randomised controlled trial [J].
Chowriappa, Ashirwad ;
Raza, Syed Johar ;
Fazili, Anees ;
Field, Erinn ;
Malito, Chelsea ;
Samarasekera, Dinesh ;
Shi, Yi ;
Ahmed, Kamran ;
Wilding, Gregory ;
Kaouk, Jihad ;
Eun, Daniel D. ;
Ghazi, Ahmed ;
Peabody, James O. ;
Kesavadas, Thenkurussi ;
Mohler, James L. ;
Guru, Khurshid A. .
BJU INTERNATIONAL, 2015, 115 (02) :336-345
[8]  
Erickson RR, 1996, IEEE J QUANT ELECT, V2, P1
[9]   A three-dimensional head-mounted display system (RoboSurgeon system) for gasless laparoendoscopic single-port partial cystectomy [J].
Fujii, Yasuhisa ;
Kihara, Kazunori ;
Yoshida, Soichiro ;
Ishioka, Junichiro ;
Matsuoka, Yoh ;
Numao, Noboru ;
Saito, Kazutaka .
VIDEOSURGERY AND OTHER MINIINVASIVE TECHNIQUES, 2014, 9 (04) :638-643
[10]   HOLOGRAPHY OF 3D SURFACE RECONSTRUCTED CT IMAGES [J].
FUJIOKA, M ;
OHYAMA, N ;
HONDA, T ;
TSUJIUCHI, J ;
SUZUKI, M ;
HASHIMOTO, S ;
IKEDA, S .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (01) :175-178