Pacemaker leads: Performance and progress

被引:0
作者
de Voogt, WG [1 ]
机构
[1] St Lucas Andreas Hosp, Dept Cardiol, NL-1061 AE Amsterdam, Netherlands
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Pacing leads remain the "weakest link" of the permanent pacing system. Lead failure has been an issue since the beginning of implantable pacemaker therapy. Modem electronics have brought about considerable progress in pacing technology, but lead design has been slower to evolve and problems persist. IS-1 standardization must be considered a significant advance, but some issues regarding IS-1 standardization persist and have been the cause of some compatibility problems. With respect to lead insulation, silicone has proved to offer total reliability for >30 years. In the search for better handling characteristics, polyurethane 80A was employed for bipolar leads, but it failed to demonstrate satisfactory insulating properties. New insulation materials, such as ethylene-fluoro-ethylene (ETFE), and coated wire technology look promising, having shown 99.32% survival at 5-year follow-up. Reliability is the main objective in lead design, but leads should provide low battery consumption as well. Low coil resistance, with high electrode impedance in steroid-eluting leads, is the standard at present. Low polarization is a desirable property for 2 main reasons: (1) in conjunction with low-threshold leads, it decreases battery consumption; and (2) it allows capture detection and, therefore, safer pacing at low battery consumption. Lead tip design as well as pacing pulse configuration can influence polarization. (C) 1999 by Excerpta Medico, Inc.
引用
收藏
页码:187D / 191D
页数:5
相关论文
共 31 条
  • [1] ADLES S, 1992, PACE PACING CLIN ELE, V15, P1086
  • [2] ALT E, 1998, ARCH MAL COEUR VAISS, V91, P140
  • [3] BELLOT PH, 1998, ARCH MAL COEUR VAISS, V91, P139
  • [4] STUDIES OF THE TISSUE REACTION INDUCED BY TRANSVENOUS PACEMAKER ELECTRODES .1. MICROSCOPIC EXAMINATION OF THE EXTENT OF CONNECTIVE-TISSUE AROUND THE ELECTRODE TIP IN THE HUMAN RIGHT VENTRICLE
    BEYERSDORF, F
    SCHNEIDER, M
    KREUZER, J
    FALK, S
    ZEGELMAN, M
    SATTER, P
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (11): : 1753 - 1759
  • [5] *BRIT STAND, 1993, SPEC LOW PROF CONN I
  • [6] A VOLUNTARY STANDARD FOR 3.2-MM UNIPOLAR AND BIPOLAR PACEMAKER LEADS AND CONNECTORS
    CALFEE, RV
    SAULSON, SH
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1986, 9 (06): : 1181 - 1185
  • [7] Automatic adjustment of pacemaker stimulation output correlated with continuously monitored capture thresholds:: A multicenter study
    Clarke, M
    Liu, B
    Schüller, H
    Binner, L
    Kennergren, C
    Guerola, M
    Weinmann, P
    Ohm, OJ
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (08): : 1567 - 1575
  • [8] DEVOOGT WG, 1998, ARCH MAL COEUR VAISS, V200, P107
  • [9] DEVOOGT WG, 1996, EUR J CARDIAC PACING, V6, P220
  • [10] INTRAVASCULAR LEAD EXTRACTION USING LOCKING STYLETS, SHEATHS, AND OTHER TECHNIQUES
    FEARNOT, NE
    SMITH, HJ
    GOODE, LB
    BYRD, CL
    WILKOFF, BL
    SELLERS, TD
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1990, 13 (12): : 1864 - 1870