Impact of temperature variation on the energy resolution of 3D position sensitive CZT gamma-ray spectrometers

被引:5
作者
Li, Wen [1 ]
Du, Yanfeng [1 ]
Yanoff, Brian D. [1 ]
Gordon, Jeffrey S. [1 ]
机构
[1] GE Global Res, Niskayuna, NY 12309 USA
来源
2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11 | 2007年
关键词
D O I
10.1109/NSSMIC.2007.4436510
中图分类号
O59 [应用物理学];
学科分类号
摘要
Prototype 3D position sensitive CZT gamma spectrometers have been developed using 10x10x10 mm(3) pixellated CZT detectors and a RENA-3 readout system from NOVA R&D. Under stable room temperature, excellent energy resolution of similar to 1% FWHM at 662 keV is consistently demonstrated for single interaction events in the detector with one time pre-measurement calibration. To test the feasibility of using the 3D CZT spectrometers for outdoor applications where ambient temperature is subject to a wide range of variation, the energy resolution performance of two detectors, one from Redlen Technologies and one from Yinnel Tech Inc., has been evaluated over the ambient temperature range from -5 to 45 degrees C. The temperature related contributors to energy resolution, such as the readout electronics response and electron trapping in CZT detectors, have been investigated. The Redlen detector shows good stability in electron trapping with typical (mu tau)(e) (electron mobility-lifetime product) of similar to 1.5e-2 cm(2)/V, but a temperature-related gain drift up to +/-0.8% is observed with contribution from readout electronics. The Yinnel Tech detector has a typical (mu tau)(e) of similar to 5e-3 cm(2)/V at room temperature and shows significantly reduced (mu tau)(e) and increased electron trapping at lower temperatures. These results indicate both detectors need temperature related multiple calibrations to avoid significant energy resolution degradation from varying ambient temperature. With multiple 3D detector response calibrations at different temperatures, energy resolution close to similar to 1% FWHM at 662 keV can be maintained for both detectors.
引用
收藏
页码:1809 / 1815
页数:7
相关论文
共 6 条
  • [1] Measurement of material uniformity using 3-D position sensitive CdZnTe gamma-ray spectrometers
    He, Z
    Li, W
    Knoll, GF
    Wehe, DK
    Stahle, CM
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 441 (03) : 459 - 467
  • [2] 3-D position sensitive CdZnTe gamma-ray spectrometers
    He, Z
    Li, W
    Knoll, GF
    Wehe, DK
    Berry, J
    Stahle, CM
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3) : 173 - 178
  • [3] High-resolution mapping of the mobility-lifetime product in CdZnTe using a nuclear microprobe
    Lohstroh, A
    Sellin, PJ
    Simon, A
    [J]. JOURNAL OF PHYSICS-CONDENSED MATTER, 2004, 16 (02) : S67 - S73
  • [4] Investigation of the asymmetric characteristics and temperature effects of CdZnTe detectors
    Sturm, BW
    He, Z
    Zurbuchen, TH
    Koehn, PL
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (05) : 2068 - 2075
  • [5] TUMER TO, 2006 IEEE NUCL SCI S
  • [6] 3-D position sensitive CdZnTe spectrometer performance using third generation VAS/TAT readout electronics
    Zhang, F
    He, Z
    Knoll, GF
    Wehe, DK
    Berry, JE
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (05) : 2009 - 2016