Development of a rapid method for the determination of glimepiride in human plasma using liquid-liquid extraction based on 96-well format micro-tubes and liquid chromatography/tandem mass spectrometry

被引:30
|
作者
Dotsikas, Y [1 ]
Kousoulos, C [1 ]
Tsatsou, G [1 ]
Loukas, YL [1 ]
机构
[1] Univ Athens, Sch Pharm, Dept Pharmaceut Chem, Lab Pharmaceut Anal & Bioequivalence Serv GLP Com, GR-15771 Athens, Greece
关键词
D O I
10.1002/rcm.2028
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A semi-automated liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed for the determination of glimepiride in human plasma. The plasma samples were treated by liquid-liquid extraction (LLE) in 1.2mL 96-well format micro-tubes. Glimepiride and the internal standard (IS) glibenclamide were extracted from human plasma by LLE, using a mixture of ethyl acetate/diethyl ether 50:50 (v/v) as the organic solvent. After vortexing, centrifugation and freezing, the supernatant organic solvent was evaporated. The analyte and IS were dissolved in a small volume of a reconstitution solution, an aliquot of which was analyzed by reversed-phase LC/MS/MS with positive ion electrospray ionization, using multiple reaction monitoring. The method proved to be sensitive and specific for both drugs, and statistical evaluation revealed excellent linearity for the range of concentrations 2.0-500.0 ng/mL with very good accuracy and inter- and intra-day precisions. The proposed method enabled the rapid and reliable determination of glimepiride in pharmacokinetic or bioequivalence studies after per os administration of a 3 or 4 mg tablet of glimepiride. Copyright (c) 2005 John Wiley & Sons, Ltd.
引用
收藏
页码:2055 / 2061
页数:7
相关论文
共 50 条
  • [31] Factorial design for the development of automated solid-phase extraction in the 96-well format for determination of tesaglitazar, in plasma, by liquid chromatography-mass spectrometry
    Svennberg, H
    Bergh, S
    Stenhoff, H
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 787 (02): : 231 - 241
  • [32] Quantitative determination of paclitaxel in human plasma using semi-automated liquid-liquid extraction in conjunction with liquid chromatography/tandem mass spectrometry
    Basileo, G
    Breda, M
    Fonte, G
    Pisano, R
    James, CA
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 32 (4-5) : 591 - 600
  • [33] Quantitative determination of rosuvastatin in human plasma by ion pair liquid-liquid extraction using liquid chromatography with electrospray ionization tandem mass spectrometry
    Lan, Ke
    Jiang, Xuehua
    Li, Yunxia
    Wang, Ling
    Zhou, Jing
    Jiang, Qian
    Ye, Limin
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 44 (02) : 540 - 546
  • [34] Indacaterol Determination in Human Urine: Validation of a Liquid-Liquid Extraction and Liquid Chromatography-Tandem Mass Spectrometry Analytical Method
    Ammari, Wesam G.
    Al-Qadhi, Zainab
    Khalil, Mohammad
    Tayyem, Rabab
    Qammaz, Samir
    Oriquat, Ghaleb
    Basheti, Iman A.
    Chrystyn, Henry
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2015, 28 (03) : 202 - 210
  • [35] HIGH-THROUGHPUT DETERMINATION OF FUDOSTEINE IN HUMAN PLASMA BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY, FOLLOWING PROTEIN PRECIPITATION IN THE 96-WELL PLATE FORMAT
    Wen, Jun
    Zhong, Dafang
    Wu, Yiwen
    Zhang, Lingli
    Fan, Guorong
    Wu, Yutian
    DRUG METABOLISM REVIEWS, 2008, 40 : 185 - 185
  • [36] High-throughput determination of fudosteine in human plasma by liquid chromatography-tandem mass spectrometry, following protein precipitation in the 96-well plate format
    Wen, Jun
    Wu, Yiwen
    Zhang, Linli
    Qi, Yunpeng
    Fan, Guorong
    Wu, Yutian
    Li, Zhen
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 867 (01): : 153 - 159
  • [37] DETERMINATION OF D-AMPHETAMINE AND DIPHENHYDRAMINE IN DOG PLASMA BY A 96-WELL FORMAT LIQUID-LIQUID EXTRACTION AND CAPILLARY ZONE ELECTROPHORESIS
    Li, Ji
    Zhong, Dafang
    Zhang, Lingli
    Pan, Yaju
    Fan, Guorong
    Wu, Yutian
    DRUG METABOLISM REVIEWS, 2008, 40 : 49 - 49
  • [38] Liquid-liquid extraction in the 96-well plate format with SRM LC MS quantitative determination of methotrexate and its major metabolite in human plasma
    Steinborner, S
    Henion, J
    ANALYTICAL CHEMISTRY, 1999, 71 (13) : 2340 - 2345
  • [39] Sensitive method for the quantitative determination of gemfibrozil in dog plasma by liquid-liquid cartridge extraction and liquid chromatography-tandem mass spectrometry
    Roadcap, BA
    Musson, DG
    Rogers, JD
    Zhao, JJ
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 791 (1-2): : 161 - 170
  • [40] Quantitative and qualitative determination of estrogen sulfates in human urine by liquid chromatography/tandem mass spectrometry using 96-well technology
    Zhang, HW
    Henion, J
    ANALYTICAL CHEMISTRY, 1999, 71 (18) : 3955 - 3964