Development of a rapid method for the determination of glimepiride in human plasma using liquid-liquid extraction based on 96-well format micro-tubes and liquid chromatography/tandem mass spectrometry

被引:30
|
作者
Dotsikas, Y [1 ]
Kousoulos, C [1 ]
Tsatsou, G [1 ]
Loukas, YL [1 ]
机构
[1] Univ Athens, Sch Pharm, Dept Pharmaceut Chem, Lab Pharmaceut Anal & Bioequivalence Serv GLP Com, GR-15771 Athens, Greece
关键词
D O I
10.1002/rcm.2028
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A semi-automated liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed for the determination of glimepiride in human plasma. The plasma samples were treated by liquid-liquid extraction (LLE) in 1.2mL 96-well format micro-tubes. Glimepiride and the internal standard (IS) glibenclamide were extracted from human plasma by LLE, using a mixture of ethyl acetate/diethyl ether 50:50 (v/v) as the organic solvent. After vortexing, centrifugation and freezing, the supernatant organic solvent was evaporated. The analyte and IS were dissolved in a small volume of a reconstitution solution, an aliquot of which was analyzed by reversed-phase LC/MS/MS with positive ion electrospray ionization, using multiple reaction monitoring. The method proved to be sensitive and specific for both drugs, and statistical evaluation revealed excellent linearity for the range of concentrations 2.0-500.0 ng/mL with very good accuracy and inter- and intra-day precisions. The proposed method enabled the rapid and reliable determination of glimepiride in pharmacokinetic or bioequivalence studies after per os administration of a 3 or 4 mg tablet of glimepiride. Copyright (c) 2005 John Wiley & Sons, Ltd.
引用
收藏
页码:2055 / 2061
页数:7
相关论文
共 50 条
  • [21] Development of a rapid liquid chromatography tandem mass spectrometry method for the determination of lisinopril, applicable for a bioequivalence study, employing a 96-well format solid phase extraction protocol
    Kousoulos, C
    Tsatsou, G
    Dotsikas, Y
    Loukas, YL
    ANALYTICA CHIMICA ACTA, 2005, 551 (1-2) : 177 - 183
  • [22] Determination of (R)- and (S)-ketoprofen in human plasma by liquid chromatography/tandem mass spectrometry following automated solid-phase extraction in the 96-well format
    Eichhold, TH
    Bailey, RE
    Tanguay, SL
    Hoke, SH
    JOURNAL OF MASS SPECTROMETRY, 2000, 35 (04): : 504 - 511
  • [23] Validation and application of a 96-well format solid-phase extraction and liquid chromatography-tandem mass spectrometry method for the quantitation of digoxin in human plasma
    Hashimoto, Yoshitaka
    Shibakawa, Kimio
    Nakade, Susumu
    Miyata, Yasuyuki
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 869 (1-2): : 126 - 132
  • [24] A simple 96-well liquid-liquid extraction with a mixture of acetonitrile and methyl t-butyl ether for the determination of a drug in human plasma by high-performance liquid chromatography with tandem mass spectrometry
    Xue, YJ
    Pursley, J
    Arnold, ME
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 34 (02) : 369 - 378
  • [25] A rapid and sensitive liquid chromatography/negative ion tandem mass spectrometry method for the determination of an indolocarbazole in human plasma using internal standard (IS) 96-well diatomaceous earth plates for solid-liquid extraction
    Wang, AQ
    Zeng, W
    Musson, DG
    Rogers, JD
    Fisher, AL
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (10) : 975 - 981
  • [26] Method development for the quantitation of ABT-578 in rabbit artery tissue by 96-well liquid-liquid extraction and liquid chromatography/tandem mass spectrometric detection
    Ji, QC
    Zhang, J
    Rodila, R
    Watson, P
    El-Shourbagy, T
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (19) : 2293 - 2298
  • [27] Assessment of matrix effects and determination of niacin in human plasma using liquid-liquid extraction and liquid chromatography-tandem mass spectrometry
    Peoples, Michael C.
    Halquist, Matthew S.
    Ismaiel, Omnia
    El-Mammli, Magda Y.
    Shalaby, Abdalla
    Karnes, H. Thomas
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (11) : 1272 - 1278
  • [28] Quantitative determination of odanacatib in human plasma using liquid-liquid extraction followed by liquid chromatography-tandem mass spectrometry analysis
    Sun, Li
    Forni, Sabrina
    Schwartz, Michael S.
    Breidinger, Sheila
    Woolf, Eric J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 885 : 15 - 23
  • [29] Sensitive Liquid Chromatography Positive Electrospray Tandem Mass Spectrometry Method for the Quantitation of Tegaserod in Human Plasma Using Liquid-Liquid Extraction
    Nirogi, Ramakrishna
    Kandikere, Vishwottam
    Mudigonda, Koteshwara
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2009, 47 (02) : 164 - 169
  • [30] Method development for the concentration determination of a protein in human plasma utilizing 96-well solid phase extraction and liquid chromatography/tandem mass spectrometric detection
    Ji, QC
    Gage, EM
    Rodila, R
    Chang, MS
    El-Shourbagy, TA
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (08) : 794 - 799