Fiber-optic In-line Mach-Zehnder Modal Interferometer for Breathing Monitoring Application

被引:0
|
作者
Wang, Ketian [1 ,2 ]
Xu, Wei [3 ]
Zhang, Na [2 ,4 ]
Li, Kunpu [1 ,2 ]
Yu, Cheungchuem [3 ]
Yu, Changyuan [5 ]
机构
[1] Univ Elect Sci & Technol China, Chengdu 611731, Sichuan, Peoples R China
[2] Natl Univ Singapore, Suzhou Res Inst, Suzhou 215123, Peoples R China
[3] Anlight Optoelect Technol Inc, Suzhou 215123, Peoples R China
[4] Soochow Univ, Suzhou 215006, Peoples R China
[5] Hong Kong Polytech Univ, Kowloon, Hong Kong, Peoples R China
来源
2017 CONFERENCE ON LASERS AND ELECTRO-OPTICS PACIFIC RIM (CLEO-PR) | 2017年
基金
中国国家自然科学基金;
关键词
Mach-Zehnder; modal interferometer; breathing monitoring; optical fiber sensor; OBSTRUCTIVE SLEEP-APNEA;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A simple fiber-optic in-line Mach-Zehnder modal interferometer is fabricated and studied for monitoring human being's breathing rate, which is one of the most important vital signs. The sensing structure is simply fabricated by a couple of up-tapers manufactured in the common telecommunication single mode fiber (SMF) by a commercial splicer. Sensing performances with different distances between the dual up tapers are addressed. The whole setup only contains one laser source, one photo-detector and one section of SMF with dual up tapers. It can real-timely monitor people's respiration rhythm without complex signal processing and the scheme is simple and low-cost.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Life in an optical fiber: Monitoring of cell cultures with microcavity in-line Mach-Zehnder interferometer
    Janik, Monika
    Sosnowska, Malwina
    Gabler, Tomasz
    Koba, Marcin
    Mysliwiec, Anna
    Kutwin, Marta
    Chwalibog, Ewa Sawosz
    Smietana, Mateusz
    BIOSENSORS & BIOELECTRONICS, 2022, 217
  • [2] Optical fiber internal mirror based fiber in-line Mach-Zehnder interferometer
    Gong, H.
    Wang, D. N.
    Xu, B.
    Ni, K.
    Liu, H.
    Zhao, C. L.
    SIXTH EUROPEAN WORKSHOP ON OPTICAL FIBRE SENSORS, 2016, 9916
  • [3] Ladder topology network based on white light fiber-optic Mach-Zehnder interferometer
    Li, Song
    Yuan, Libo
    Mokhtar, Ferhati
    2011 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTICAL SENSORS AND APPLICATIONS, 2011, 8199
  • [4] EFFECT OF BENDING AND ORIENTATION ON THE FIBER MODAL MACH-ZEHNDER INTERFEROMETER
    Liu, Yan
    Liu, Bo
    Miao, Yinping
    Zhang, Hao
    Liu, Jian
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2012, 54 (01) : 136 - 139
  • [5] Miniature and robust optical fiber in-line Mach-Zehnder interferometer based on a hollow ellipsoid
    Gong, H.
    Wang, D. N.
    Xu, B.
    Ni, K.
    Liu, H.
    Zhao, C. L.
    OPTICS LETTERS, 2015, 40 (15) : 3516 - 3519
  • [6] Theory of a fiber-optic double-pass Mach-Zehnder interferometer for use in a Brillouin intensity based fiber-optic temperature sensor
    De Souza, K
    17TH INTERNATIONAL CONFERENCE ON OPTICAL FIBRE SENSORS, PTS 1 AND 2, 2005, 5855 : 639 - 642
  • [7] A strain sensor based on in-line fiber Mach-Zehnder interferometer in twin-core photonic crystal fiber
    Qureshi, Khurram Karim
    Liu, Zhengyong
    Tam, Hwa-Yaw
    Zia, M. Fahad
    OPTICS COMMUNICATIONS, 2013, 309 : 68 - 70
  • [8] Enhancement of Refractive Index Sensitivity by Bending a Core-Offset In-Line Fiber Mach-Zehnder Interferometer
    Yu, Fangda
    Xue, Peng
    Zheng, Jie
    IEEE SENSORS JOURNAL, 2019, 19 (09) : 3328 - 3334
  • [10] High-Sensitive Fiber-Optic Refractometer Based on a Core-Diameter-Mismatch Mach-Zehnder Interferometer
    Rong, Qiangzhou
    Qiao, Xueguang
    Wang, Ruohui
    Sun, Hao
    Hu, Manli
    Feng, Zhongyao