Spatial Restriction of Neural Activation Using Focused Multipolar Stimulation With a Retinal Prosthesis

被引:26
作者
Spencer, Thomas C. [1 ,2 ]
Fallon, James B. [1 ,2 ]
Thien, Patrick C. [1 ,2 ]
Shivdasani, Mohit N. [1 ,2 ]
机构
[1] Bion Inst, 384-388 Albert St, East Melbourne, Vic 3002, Australia
[2] Univ Melbourne, Dept Med Bion, East Melbourne, Australia
基金
英国医学研究理事会;
关键词
retinal prosthesis; electrical stimulation; current focusing; in vivo electrophysiology; suprachoroidal; SUPRACHOROIDAL-TRANSRETINAL STIMULATION; AFFECTING PERCEPTUAL THRESHOLDS; ELECTRICAL-STIMULATION; ELECTRODE STIMULATION; MICROELECTRODE ARRAY; COCHLEAR IMPLANTS; STRIATE CORTEX; MONOPOLAR; TRIPOLAR; ORGANIZATION;
D O I
10.1167/iovs.16-19325
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. The resolution provided by present state-of-the-art retinal prostheses is severely limiting for recipients, partly due to the broad spread of activation in the retina in response to monopolar (MP) electrical stimulation. Focused multipolar (FMP) stimulation has been shown to restrict neural activation in the cochlea compared to MP stimulation. We extended the FMP stimulation technique to a two-dimensional electrode array and compared its efficacy to MP and hexapolar (HP) stimulation in the retina. METHODS. Normally-sighted cats (n = 6) were implanted with a suprachoroidal electrode array containing 42 electrodes. Multichannel multiunit spiking activity was recorded from the visual cortex in response to MP, HP, and FMP retinal stimulation. RESULTS. When inferring retinal spread using voltage recordings off the stimulating array, FMP stimulation showed significantly reduced voltages in regions surrounding the primary stimulating electrode. When measuring the retinal and cortical selectivity of neural responses, FMP and HP stimulation showed significantly higher selectivity compared to MP stimulation (separate 2-way ANOVAs, P < 0.05). However, the lowest cortical thresholds for each stimulating electrode were higher for FMP and HP compared to MP stimulation (1-way ANOVA, P < 0.001). No significant differences were observed between FMP and HP stimulation in any measures. CONCLUSIONS. Focused multipolar and HP stimulation using a two-dimensional array are promising techniques to reduce the spread of activation for a retinal prosthesis. Clinical application would be expected to result in smaller phosphenes; thus, reducing phosphene overlap between electrodes and increasing the resolution at the expense of higher thresholds for activation.
引用
收藏
页码:3181 / 3191
页数:11
相关论文
共 60 条
[1]   Activation of retinal ganglion cells following epiretinal electrical stimulation with hexagonally arranged bipolar electrodes [J].
Abramian, Miganoosh ;
Lovell, Nigel H. ;
Morley, John W. ;
Suaning, Gregg J. ;
Dokos, Socrates .
JOURNAL OF NEURAL ENGINEERING, 2011, 8 (03)
[2]   Blind subjects implanted with the Argus II retinal prosthesis are able to improve performance in a spatial-motor task [J].
Ahuja, A. K. ;
Dorn, J. D. ;
Caspi, A. ;
McMahon, M. J. ;
Dagnelie, G. ;
daCruz, L. ;
Stanga, P. ;
Humayun, M. S. ;
Greenberg, R. J. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (04) :539-543
[3]  
[Anonymous], 1988, Signal Detection Theory and Psychophysics
[4]  
Aplin E, 2015, THESIS
[5]   First-in-Human Trial of a Novel Suprachoroidal Retinal Prosthesis [J].
Ayton, Lauren N. ;
Blamey, Peter J. ;
Guymer, Robyn H. ;
Luu, Chi D. ;
Nayagam, David A. X. ;
Sinclair, Nicholas C. ;
Shivdasani, Mohit N. ;
Yeoh, Jonathan ;
McCombe, Mark F. ;
Briggs, Robert J. ;
Opie, Nicholas L. ;
Villalobos, Joel ;
Dimitrov, Peter N. ;
Varsamidis, Mary ;
Petoe, Matthew A. ;
McCarthy, Chris D. ;
Walker, Janine G. ;
Barnes, Nick ;
Burkitt, Anthony N. ;
Williams, Chris E. ;
Shepherd, Robert K. ;
Allen, Penelope J. .
PLOS ONE, 2014, 9 (12)
[6]   Current steering and current focusing in cochlear implants: Comparison of monopolar, tripolar, and virtual channel electrode configurations [J].
Berenstein, Carlo K. ;
Mens, Lucas H. M. ;
Mulder, Jef J. S. ;
Vanpoucke, Filiep J. .
EAR AND HEARING, 2008, 29 (02) :250-260
[7]   Threshold and channel interaction in cochlear implant users: Evaluation of the tripolar electrode configuration [J].
Bierer, Julie Arenberg .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2007, 121 (03) :1642-1653
[8]   Electrical field interactions in different cochlear implant systems [J].
Boëx, C ;
de Balthasar, C ;
Kós, MI ;
Pelizzone, M .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2003, 114 (04) :2049-2057
[9]   Simulating prosthetic vision: II. Measuring functional capacity [J].
Chen, Spencer C. ;
Suaning, Gregg J. ;
Morley, John W. ;
Lovell, Nigel H. .
VISION RESEARCH, 2009, 49 (19) :2329-2343
[10]   Visual cortex responses to suprachoroidal electrical stimulation of the retina: effects of electrode return configuration [J].
Cicione, Rosemary ;
Shivdasani, Mohit N. ;
Fallon, James B. ;
Luu, Chi D. ;
Allen, Penny J. ;
Rathbone, Graeme D. ;
Shepherd, Robert K. ;
Williams, Chris E. .
JOURNAL OF NEURAL ENGINEERING, 2012, 9 (03)