Simultaneous determination of propofol and its glucuronide in whole blood by liquid chromatography-electrospray tandem mass spectrometry and the influence of sample storage conditions on the reliability of the test results

被引:21
作者
Sorensen, Lambert K. [1 ]
Hasselstrom, Jorgen B. [1 ]
机构
[1] Aarhus Univ, Dept Forens Med, Sect Forens Chem, DK-8200 Aarhus N, Denmark
关键词
Propofol; Propofol glucuronide; Blood; Stability; LC-MS/MS; SOLID-PHASE EXTRACTION; HUMAN PLASMA; DERIVATIZATION;
D O I
10.1016/j.jpba.2015.02.035
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Propofol (2,6-diisopropylphenol) is commonly used as an anaesthetic agent but is also abused for recreational purposes. Several cases of fatalities involving self-administered propofol have been reported. For rapid quantification of propofol and propofol beta-D-glucuronide (propofol G) in clinical and forensic cases, an ultra-performance liquid chromatography-tandem mass spectrometry method using pneumatically assisted electrospray ionisation has been developed. The technique has been validated on both antemortem and post-mortem human whole blood. The proteins in the blood samples were removed by the addition of a mixture of methanol and acetonitrile, and the extract was cleaned up by solid phase extraction. The extract was concentrated in dimethyl sulphoxide. The system was calibrated using matrix-matched calibrants combined with isotope dilution. The lower limits of quantification were 0.01 and 0.02 mg/L for propofol and 0.02 and 0.04 mg/L for propofol G in ante-mortem and post-mortem whole blood, respectively. The relative intra-laboratory reproducibility standard deviation was less than 10% at concentrations of 0.2 mg/L or higher. The mean true extraction recovery was 85% for propofol and 81% for propofol G. The trueness of the propofol determination expressed as the relative bias of the test results was within 6% at concentration levels of 0.01-8.5 mg/L. Propofol was less stable in blood stabilised with a citrate-EDTA-fluoride mixture than in blood stabilised with an oxalate-fluoride mixture. The stability was lower at -20 degrees C than at 5 degrees C and -80 degrees C. Propofol G did not show instability under the storage conditions tested. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:158 / 163
页数:6
相关论文
共 22 条
[1]  
[Anonymous], 1994, ISO 5725-2 Accuracy (trueness and precision) of measurement methods and results - Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
[2]   A new method for the quantitation of propofol in human plasma: efficient solid-phase extraction and liquid chromatography/APCI-triple quadrupole mass spectrometry detection [J].
Bajpai, L ;
Varshney, M ;
Seubert, CN ;
Dennis, DM .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 810 (02) :291-296
[3]  
Baselt R. C., 2011, DISPOSITION TOXIC DR, P1439
[4]   Development of a rapid and sensitive LC-ESI/MS/MS assay for the quantification of propofol using a simple off-line dansyl chloride derivatization reaction to enhance signal intensity [J].
Beaudry, F ;
Guénette, SA ;
Winterborn, A ;
Marier, JF ;
Vachon, P .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 39 (3-4) :411-417
[5]  
Bell D M, 1999, AANA J, V67, P133
[6]  
Bienert Agnieszka, 2005, Acta Pol Pharm, V62, P95
[7]   THE FIRST FATAL 2,6-DI-ISOPROPYLPHENOL (PROPOFOL) POISONING IN SINGAPORE - A CASE-REPORT [J].
CHAO, TC ;
LO, DST ;
CHUI, PPS ;
KOH, TH .
FORENSIC SCIENCE INTERNATIONAL, 1994, 66 (01) :1-7
[8]   Quantitative measurement of propofol and in main glucuroconjugate metabolites in human plasma using solid phase extraction-liquid chromatography-tandem mass spectrometry [J].
Cohen, S. ;
Lhuillier, F. ;
Mouloua, Y. ;
Vignal, B. ;
Favetta, P. ;
Guitton, J. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 854 (1-2) :165-172
[9]   Suicide by Self-Administration of a Drug Mixture (Propofol, Midazolam, and Zolpidem) in an Anesthesiologist: The First Case Report in Italy [J].
Colucci, Anna Pia ;
Gagliano-Candela, Roberto ;
Aventaggiato, Lucia ;
De Donno, Antonio ;
Leonardi, Sabrina ;
Strisciullo, Giuseppe ;
Introna, Francesco .
JOURNAL OF FORENSIC SCIENCES, 2013, 58 (03) :837-841
[10]   Propofol concentrations in whole blood:: Influence of anticoagulants and storage time [J].
Cuadrado, A ;
Solares, G ;
González, S ;
Sánchez, B ;
Armijo, JA .
METHODS AND FINDINGS IN EXPERIMENTAL AND CLINICAL PHARMACOLOGY, 1998, 20 (04) :297-300